Abstract: Gravity circulation loop for the cryopumps of the space simulator is introduced, and two phase mathematic model of flow heat transfer is analyzed as well. Based on this model, the liquid nitrogen (LN2) gravity circulation loop including its equipment and layout is designed and has served as LN2 feeding system for cryopumps in one large space simulator. With the help of control software and human machine interface, this system can be operated flexibly, simply, and automatically under four conditions. When running this system, the results show that the cryopumps can be cooled down and maintained under the required temperature, 120 K.
Abstract: Liquid spray heat exchanger is the critical equipment of temperature regulating system by gaseous nitrogen which realizes the environment temperature in the range of -180 ℃~+180 ℃. Liquid nitrogen is atomized into smaller liquid drops through liquid nitrogen sprayer and then contacts with gaseous nitrogen to be cooled. By adjusting the pressure of liquid nitrogen and gaseous nitrogen, the flowrate of liquid nitrogen is changed to realize the required outlet temperature of heat exchanger. The temperature accuracy of shrouds is ±1 ℃. Liquid nitrogen spray heat exchanger is simulated by CATIA, and the numerical simulation is performed by FLUENT. The comparison between the tests and numerical simulation is conducted. Moreover, the results help to improve the design of liquid nitrogen spray heat exchanger.
Abstract: Oxidative stress associated with semen cryopreservation may result in lipid peroxidation (LPO), DNA damage and apoptosis, leading to decreased sperm motility and fertilization ability. Curcumin (CUR), a natural phenol isolated from Curcuma longa Linn. has been presented as a possible supplement for a more effective semen cryopreservation because of its antioxidant properties. This study focused to evaluate the effects of CUR on selected oxidative stress parameters in cryopreserved bovine semen. 20 bovine ejaculates were split into two aliquots and diluted with a commercial semen extender containing CUR (50 μmol/L) or no supplement (control), cooled to 4 °C, frozen and kept in liquid nitrogen. Frozen straws were thawed in a water bath for subsequent experiments. Computer assisted semen analysis was used to evaluate spermatozoa motility, and reactive oxygen species (ROS) generation was quantified by using luminometry. Superoxide generation was evaluated with the NBT test, and LPO was assessed via the TBARS assay. CUR supplementation significantly (P
Abstract: The influence of canned cycles and cutting parameters on hole quality in cryogenic drilling has been investigated experimentally and analytically. A three-level, three-parameter experiment was conducted by using the design-of-experiment methodology. The three levels of independent input parameters were the following: for canned cycles—a chip-breaking canned cycle (G73), a spot drilling canned cycle (G81), and a deep hole canned cycle (G83); for feed rates—0.2, 0.3, and 0.4 mm/rev; and for cutting speeds—60, 75, and 100 m/min. The selected work and tool materials were aluminum 6061-6T and high-speed steel (HSS), respectively. For cryogenic cooling, liquid nitrogen (LN2) was used and was applied externally. The measured output parameters were the three widely used quality characteristics of drilled holes—diameter error, circularity, and surface roughness. Pareto ANOVA was applied for analyzing the results. The findings revealed that the canned cycle has a significant effect on diameter error (contribution ratio 44.09%) and small effects on circularity and surface finish (contribution ratio 7.25% and 6.60%, respectively). The best results for the dimensional accuracy and surface roughness were achieved by G81. G73 produced the best circularity results; however, for dimensional accuracy, it was the worst level.
Abstract: Temperature regulating system by gaseous nitrogen is
of importance to the space environment simulator, which keeps the
shrouds in the temperature range from -150°C to +150°C. Liquid
nitrogen spray equipment is one of the most critical parts in the
temperature regulating system by gaseous nitrogen. Y type jet
atomizer and internal mixing atomizer of the liquid nitrogen spray
equipment are studied in this paper, 2D/3D atomizer model was
established and grid division was conducted respectively by the
software of Catia and ICEM. Based on the above preparation,
numerical simulation on the spraying process of the atomizer by
FLUENT is performed. Using air and water as the medium,
comparison between the tests and numerical simulation was conducted
and the results of two ways match well. Hence, it can be conclude that
this atomizer model can be applied in the numerical simulation of
liquid nitrogen spray equipment.
Abstract: The atomization effect is an important factor of the heat transfer of liquid nitrogen spray. In this paper, two kinds of internal-mixing twin-fluid atomizers were design. According to the fracture theory and fluid mechanics, the model is established to simulate atomization effect. The results showed that: Internal-mixing atomizers, with the liquid nitrogen atomization size from 20um to 40um, have superior performance. Y-jet atomizer spray speed is greater than Multi-jet atomizer, and it can improve the efficiency of heat transfer between the liquid nitrogen and its spray object. Multi-jet atomizer atomization cone angle is about 30°, Y-jet atomizer atomization cone angle is about 20°. During atomizer selection, the size of the heat transfer area should be considered.
Abstract: Electrical discharge machining (EDM) is well
established machining technique mainly used to machine complex
geometries on difficult-to-machine materials and high strength
temperature resistant alloys. In the present research, the objective is
to study the shape of the electrode and establish the application of
liquid nitrogen in reducing distortion of the electrode during
electrical discharge machining of M2 grade high speed steel using
copper electrodes. Study of roundness was performed on the
electrode to observe the shape of the electrode for both conventional
EDM and EDM with cryogenically cooled electrode. Scanning
Electron Microscope (SEM) has been used to study the shape of
electrode tip. The effect of various parameters such as discharge
current and pulse on time has been studied to understand the behavior
of distortion of electrode. It has been concluded that the shape
retention is better in case of liquid nitrogen cooled electrode.
Abstract: This paper presented a novel combined cycle of air separation and natural gas liquefaction. The idea is that natural gas can be liquefied, meanwhile gaseous or liquid nitrogen and oxygen are produced in one combined cryogenic system. Cycle simulation and exergy analysis were performed to evaluate the process and thereby reveal the influence of the crucial parameter, i.e., flow rate ratio through two stages expanders β on heat transfer temperature difference, its distribution and consequent exergy loss. Composite curves for the combined hot streams (feeding natural gas and recycled nitrogen) and the cold stream showed the degree of optimization available in this process if appropriate β was designed. The results indicated that increasing β reduces temperature difference and exergy loss in heat exchange process. However, the maximum limit value of β should be confined in terms of minimum temperature difference proposed in heat exchanger design standard and heat exchanger size. The optimal βopt under different operation conditions corresponding to the required minimum temperature differences was investigated.
Abstract: Since 2005, an SRF module of CESR type serves as the
accelerating cavity at the Taiwan Light Source in the National
Synchrotron Radiation Research Center. A 500-MHz niobium cavity
is immersed in liquid helium inside this SRF module. To reduce heat
load, the liquid helium vessel is thermally shielded by
liquid-nitrogen-cooled copper layer, and the beam chambers are also
anchored with pipes of the liquid nitrogen flow in middle of the liquid
helium vessel and the vacuum vessel. A strong correlation of the
movement of the cavity-s frequency tuner with the temperature
variation of parts cooled with liquid nitrogen was observed. A
previous study on a spare SRF module with the niobium cavity cooled
by liquid nitrogen instead of liquid helium, satisfactory suppression of
the thermal oscillation was achieved by attaching a temporary buffer
tank for the vented shielding nitrogen flow from the SRF module. In
this study, a home-made buffer tank is designed and integrated to the
spare SRF module with cavity cooled by liquid helium. Design,
construction, integration, and preliminary test results of this buffer
tank are presented.
Abstract: A study was undertaken to investigate the effect of
liquid nitrogen aeration on mortalities of adult Cryptolestes
furrugineus, rusty grain beetles, in a prototype cardboard grain bin
equipped with an aeration system. The grain bin was filled with Hard
Red Spring wheat and liquid nitrogen was introduced from the bottom
of the bin. The survival of both cold acclimated and unacclimated C.
furrugineus was tested. The study reveals that cold acclimated insects
had higher survival than unacclimated insects under similar cooling
conditions. In most cases, mortalities of as high as 100% were
achieved at the bottom 100 cm of the grain bin for unacclimated
insects for most of the trials. Insect survival increased as the distance
from the bottom of the grain bin increased. There was no adverse
effect of liquid nitrogen aeration on wheat germination.
Abstract: An effect of rolling temperature on the mechanical properties and microstructural evolution of an Al-Mg-Si alloy was studied. The material was rolled up to a true strain of ~0.7 at three different temperatures viz; room temperature, liquid propanol and liquid nitrogen. The liquid nitrogen rolled sample exhibited superior properties with a yield and tensile strength of 332 MPa and 364 MPa, respectively, with a reasonably good ductility of ~9%. The liquid nitrogen rolled sample showed around 54 MPa increase in tensile strength without much reduction in the ductility as compared to the as received T6 condition alloy. The microstructural details revealed equiaxed grains in the annealed and solutionized sample and elongated grains in the rolled samples. In addition, the cryorolled samples exhibited fine grain structure compared to the room temperature rolled samples.
Abstract: The aim of this study was to synthesize the single
walled carbon nanotubes (SWCNTs) and determine their hydrogen
storage capacities. SWCNTs were firstly synthesized by chemical
vapor deposition (CVD) of acetylene (C2H2) on a magnesium oxide
(MgO) powder impregnated with an iron nitrate (Fe(NO3)3·9H2O)
solution. The synthesis parameters were selected as: the synthesis
temperature of 800°C, the iron content in the precursor of 5% and the
synthesis time of 30 min. Purification process of SWCNTs was
fulfilled by microwave digestion at three different temperatures (120,
150 and 200 °C), three different acid concentrations (0.5, 1 and 1.5
M) and for three different time intervals (15, 30 and 60 min). Nitric
acid (HNO3) was used in the removal of the metal catalysts. The
hydrogen storage capacities of the purified materials were measured
using volumetric method at the liquid nitrogen temperature and gas
pressure up to 100 bar. The effects of the purification conditions such
as temperature, time and acid concentration on hydrogen adsorption
were investigated.
Abstract: Polymeric microreactors have emerged as a new
generation of carriers that hold tremendous promise in the areas of
cancer therapy, controlled delivery of drugs, for removal of
pollutants etc. Present work reports a simple and convenient
methodology for synthesis of polystyrene and poly caprolactone
microreactors. An aqueous suspension of carboxylated (1μm)
polystyrene latex particles was mixed with toluene solution followed
by freezing with liquid nitrogen. Freezed particles were incubated at
-20°C and characterized for formation of voids on the surface of
polymer microspheres by Field Emission Scanning Electron
Microscope. The hollow particles were then overnight incubated at
40ºC with unfunctionalized quantum dots (QDs) in 5:1 ratio. QDs
Encapsulated polystyrene microcapsules were characterized by
fluorescence microscopy.
Likewise Poly ε-caprolactone microreactors were prepared by
micro-volcanic rupture of freeze dried microspheres synthesized
using emulsification of polymer with aqueous Poly vinyl alcohol and
freezed with liquid nitrogen. Microreactors were examined with Field
Emission Scanning Electron Microscope for size and morphology.
Current study is an attempt to create hollow polymer particles which
can be employed for microencapsulation of nanoparticles and drug
molecules.