Abstract: We have measured the pressure drop and convective
heat transfer coefficient of water – based AL(25nm),AL2O3(30nm)
and CuO(50nm) Nanofluids flowing through a uniform heated
circular tube in the fully developed laminar flow regime. The
experimental results show that the data for Nanofluids friction factor
show a good agreement with analytical prediction from the Darcy's
equation for single-phase flow. After reducing the experimental
results to the form of Reynolds, Rayleigh and Nusselt numbers. The
results show the local Nusselt number and temperature have
distribution with the non-dimensional axial distance from the tube
entry. Study decided that thenNanofluid as Newtonian fluids through
the design of the linear relationship between shear stress and the rate
of stress has been the study of three chains of the Nanofluid with
different concentrations and where the AL, AL2O3 and CuO – water
ranging from (0.25 - 2.5 vol %). In addition to measuring the four
properties of the Nanofluid in practice so as to ensure the validity of
equations of properties developed by the researchers in this area and
these properties is viscosity, specific heat, and density and found that
the difference does not exceed 3.5% for the experimental equations
between them and the practical. The study also demonstrated that the
amount of the increase in heat transfer coefficient for three types of
Nano fluid is AL, AL2O3, and CuO – Water and these ratios are
respectively (45%, 32%, 25%) with insulation and without insulation
(36%, 23%, 19%), and the statement of any of the cases the best
increase in heat transfer has been proven that using insulation is
better than not using it. I have been using three types of Nano
particles and one metallic Nanoparticle and two oxide Nanoparticle
and a statement, whichever gives the best increase in heat transfer.
Abstract: This paper presents a several diagnostic methods designed to electrical machinesespecially for permanent magnets (PM) machines. Those machines are commonly used in small wind and water systems and vehicles drives.Thosemethodsare preferred by the author in periodic diagnostic of electrical machines. The special attentionshould be paid to diagnostic method of turn-to-turn insulation and vibrations. Both of those methodswere createdinInstitute of Electrical Drives and MachinesKomel. The vibration diagnostic method is the main thesis of author’s doctoral dissertation. This is method of determination the technical condition of PM electrical machine basing on its own signals is the subject of patent application No P.405669. Specific structural properties of machines excited by permanent magnets are used in this method - electromotive force (EMF) generated due to vibrations. There was analysed number of publications which describe vibration diagnostic methods and tests of electrical machines with permanent magnets and there was no method found to determine the technical condition of such machine basing on their own signals.
Abstract: Plants are commonly known for its positive
correlation in reducing temperature. Since it can benefit buildings by
modifying the microclimate, it-s also believed capable of reducing
the internal temperature. Various experiments have been done in
Universiti Sains Malaysia, Penang to investigate the comparison in
thermal benefits between two rooms, one being a typical control
room (exposed wall) and the other a biofacade room (plant shaded
wall). The investigations were conducted during non-rainy season for
approximately a month. Climbing plant Psophocarpus
tetrogonobulus from legume species was selected as insulation for
the biofacade wall. Conclusions were made on whether the biofacade
can be used to tackle the energy efficiency, based on the parameters
taken into consideration.
Abstract: At present, the tendency to implement the conditionbased
maintenance (CBM), which allows the optimization of the
expenses for equipment monitoring, is more and more evident; also,
the transformer substations with remote monitoring are increasingly
used. This paper reviews all the advantages of the on-line monitoring
and presents an equipment for on-line monitoring of bushings, which
is the own contribution of specialists who are the authors of this
paper. The paper presents a study of the temperature field, using the
finite element method. For carrying out this study, the 3D modelling
of the above mentioned bushing was performed. The analysis study is
done taking into account the extreme thermal stresses, focusing at the
level of the first cooling wing section of the ceramic insulator. This
fact enables to justify the tanδ variation in time, depending on the
transformer loading and the environmental conditions. With a view
to reducing the variation of dielectric losses in bushing insulation, the
use of ferrofuids instead of mineral oils is proposed.
Abstract: Power transformer consists of components which are
under consistent thermal and electrical stresses. The major
component which degrades under these stresses is the paper
insulation of the power transformer. At site, lightning impulses and
cable faults may cause the winding deformation. In addition, the
winding may deform due to impact during transportation. A
deformed winding will excite more stress to its insulating paper thus
will degrade it. Insulation degradation will shorten the life-span of
the transformer. Currently there are two methods of detecting the
winding deformation which are Sweep Frequency Response
Analysis (SFRA) and Low Voltage Impulse Test (LVI). The latter
injects current pulses to the winding and capture the admittance
plot. In this paper, a transformer which experienced overheating and
arcing was identified, and both SFRA and LVI were performed.
Next, the transformer was brought to the factory for untanking. The
untanking results revealed that the LVI is more accurate than the
SFRA method for this case study.
Abstract: Degradation of polymeric insulation systems of
electrical equipments increases the space charge density and the
concentration of electrical dipoles. By consequence, the maximum
values and the slopes of absorption/resorption (A/R) currents can
change with insulation systems ageing. In this paper, an analysis of
the nature of the A/R currents and the importance of their
components, especially the polarization current and the current given
by the space charge, is presented. The experimental study concerns
the A/R currents measurements of plane samples (made from
CALMICAGLAS tapes), virgin and thermally accelerated aged. The
obtained results show that the ageing process produces an increase of
the values and a decrease of shapes of the A/R currents. Finally, the
possibility of estimating insulations ageing state and lifetime from
A/R currents measurements is discussed.
Abstract: The major objective of this study is to understand the
potential of a newly fabricated equipment to study the thermal
properties of nonwoven textile fabrics treated with aerogel at subzero
temperatures. Thermal conductivity was calculated by using the
empirical relation Fourier’s law, The relationship between the
thermal conductivity and thermal resistance of the samples were
studied at various environmental temperatures (which was set in the
clima temperature system between +25oC to -25oC). The newly
fabricated equipment was found to be a suitable for measuring at
subzero temperatures. This field of measurements is being developed
and will be the subject of further research which will be more suitable
for measurement of the various thermal characteristics.
Abstract: TUSAT is a prospective Turkish
Communication Satellite designed for providing mainly data
communication and broadcasting services through Ku-Band
and C-Band channels. Thermal control is a vital issue in
satellite design process. Therefore, all satellite subsystems and
equipments should be maintained in the desired temperature
range from launch to end of maneuvering life. The main
function of the thermal control is to keep the equipments and
the satellite structures in a given temperature range for various
phases and operating modes of spacecraft during its lifetime.
This paper describes the thermal control design which uses
passive and active thermal control concepts. The active
thermal control is based on heaters regulated by software via
thermistors. Alternatively passive thermal control composes of
heat pipes, multilayer insulation (MLI) blankets, radiators,
paints and surface finishes maintaining temperature level of
the overall carrier components within an acceptable value.
Thermal control design is supported by thermal analysis using
thermal mathematical models (TMM).
Abstract: This paper presents the results of a comprehensive
investigation of five blackouts that occurred on 28 August to 8
September 2011 due to bushing failures of the 132/33 kV, 125 MVA
transformers at JBB Ali Grid station. The investigation aims to
explore the root causes of the bushing failures and come up with
recommendations that help in rectifying the problem and avoiding the
reoccurrence of similar type of incidents. The incident reports about
the failed bushings and the SCADA reports at this grid station were
examined and analyzed. Moreover, comprehensive power quality
field measurements at ten 33/11 kV substations (S/Ss) in JBB Ali
area were conducted, and frequency scans were performed to verify
any harmonic resonance frequencies due to power factor correction
capacitors. Furthermore, the daily operations of the on-load tap
changers (OLTCs) of both the 125 MVA and 20 MVA transformers
at JBB Ali Grid station have been analyzed. The investigation
showed that the five bushing failures were due to a local problem, i.e.
internal degradation of the bushing insulation. This has been
confirmed by analyzing the time interval between successive OLTC
operations of the faulty grid transformers. It was also found that
monitoring the number of OLTC operations can help in predicting
bushing failure.
Abstract: The study and development of an innovative material
for building insulation is really important for a sustainable society in order to improve comfort and reducing energy consumption. The aim of this work is the development of insulating panels for
sustainable buildings based on an innovative material made by
cardboard and Phase Change Materials (PCMs).
The research has consisted in laboratory tests whose purpose has been the obtaining of the required properties for insulation panels: lightweight, porous structures and mechanical resistance. PCMs have been used for many years in the building industry as
smart insulation technology because of their properties of storage and release high quantity of latent heat at useful specific temperatures [1]- [2].
The integration of PCMs into cellulose matrix during the waste paper recycling process has been developed in order to obtain a
composite material.
Experiments on the productive process for the realization of insulating panels were done in order to make the new material
suitable for building application. The addition of rising agents
demonstrated the possibility to obtain a lighter structure with better
insulation properties.
Several tests were conducted to verify the new panel properties. The results obtained have shown the possibility to realize an
innovative and sustainable material suitable to replace insulating panels currently used.
Abstract: Since large power transformers are the most
expensive and strategically important components of any power
generator and transmission system, their reliability is crucially
important for the energy system operation. Also, Circuit breakers are
very important elements in the power transmission line so monitoring
the events gives a knowledgebase to determine time to the next
maintenance. This paper deals with the introduction of the
comparative method of the state estimation of transformers and
Circuit breakers using continuous monitoring of voltage, current.
This paper gives details a new method based on wavelet to apparatus
insulation monitoring. In this paper to insulation monitoring of
transformer, a new method based on wavelet transformation and
neutral point analysis is proposed. Using the EMTP tools, fault in
transformer winding and the detailed transformer winding model
were simulated. The current of neutral point of winding was analyzed
by wavelet transformation. It is shown that the neutral current of the
transformer winding has useful information about fault in insulation
of the transformer.
Abstract: Worldwide many electrical equipment insulation
failures have been reported caused by switching operations, while
those equipments had previously passed all the standard tests and
complied with all quality requirements. The problem is mostly
associated with high-frequency overvoltages generated during
opening or closing of a switching device. The transients generated
during switching operations in a Gas Insulated Substation (GIS) are
associated with high frequency components in the order of few tens
of MHz.
The frequency spectrum of the VFTO generated in the 220/66 kV
Wadi-Hoff GIS is analyzed using Fast Fourier Transform technique.
The main frequency with high voltage amplitude due to the operation
of disconnector (DS5) is 5 to 10 MHz, with the highest amplitude at 9
MHz. The main frequency with high voltage amplitude due to the
operation of circuit breaker (CB5) is 1 to 25 MHz, with the highest
amplitude at 2 MHz.
Mitigating techniques damped the oscillating frequencies
effectively. The using of cable terminal reduced the frequency
oscillation effectively than that of OHTL terminal. The using of a
shunt capacitance results in vanishing the high frequency
components. Ferrite rings reduces the high frequency components
effectively especially in the range 2 to 7 MHz. The using of RC and
RL filters results in vanishing the high frequency components.
Abstract: Adhesively bonded joints are preferred over the
conventional methods of joining such as riveting, welding, bolting
and soldering. Some of the main advantages of adhesive joints
compared to conventional joints are the ability to join dissimilar
materials and damage-sensitive materials, better stress distribution,
weight reduction, fabrication of complicated shapes, excellent
thermal and insulation properties, vibration response and enhanced
damping control, smoother aerodynamic surfaces and an
improvement in corrosion and fatigue resistance. This paper presents
the behavior of adhesively bonded joints subjected to combined
thermal loadings, using the numerical methods. The joint
configuration considers aluminum as central adherend with six
different outer adherends including aluminum, steel, titanium, boronepoxy,
unidirectional graphite-epoxy and cross-ply graphite-epoxy
and epoxy-based adhesives. Free expansion of the joint in x
direction was permitted and stresses in adhesive layer and interfaces
calculated for different adherends.
Abstract: In this study, an ablation, mechanical and thermal properties of a rocket motor insulation from phenolic/ fiber matrix composites forming a laminate with different fiber between fiberglass and locally available synthetic fibers. The phenolic/ fiber matrix composites was mechanics and thermal properties by means of tensile strength, ablation, TGA and DSC. The design of thermal insulation involves several factors.Determined the mechanical properties according to MIL-I-24768: Density >1.3 g/cm3, Tensile strength >103 MPa and Ablation
Abstract: Combined experimental and computational analysis of
hygrothermal performance of an interior thermal insulation system
applied on a brick wall is presented in the paper. In the experimental
part, the functionality of the insulation system is tested at simulated
difference climate conditions using a semi-scale device. The
measured temperature and relative humidity profiles are used for the
calibration of computer code HEMOT that is finally applied for a
long-term hygrothermal analysis of the investigated structure.
Abstract: High voltage generators are being subject to higher
voltage rating and are being designed to operate in harsh conditions.
Stator windings are the main component of generators in which
Electrical, magnetically and thermal stresses remain major failures
for insulation degradation accelerated aging. A large number of
generators failed due to stator winding problems, mainly insulation
deterioration. Insulation degradation assessment plays vital role in the
asset life management. Mostly the stator failure is catastrophic
causing significant damage to the plant. Other than generation loss,
stator failure involves heavy repair or replacement cost. Electro
thermal analysis is the main characteristic for improvement design of
stator slot-s insulation. Dielectric parameters such as insulation
thickness, spacing, material types, geometry of winding and slot are
major design consideration. A very powerful method available to
analyze electro thermal performance is Finite Element Method
(FEM) which is used in this paper. The analysis of various stator coil
and slot configurations are used to design the better dielectric system
to reduce electrical and thermal stresses in order to increase the
power of generator in the same volume of core. This paper describes
the process used to perform classical design and improvement
analysis of stator slot-s insulation.
Abstract: The major part of light weight timber constructions
consists of insulation. Mineral wool is the most commonly used
insulation due to its cost efficiency and easy handling. The fiber
orientation and porosity of this insulation material enables flowthrough.
The air flow resistance is low. If leakage occurs in the
insulated bay section, the convective flow may cause energy losses
and infiltration of the exterior wall with moisture and particles. In
particular the infiltrated moisture may lead to thermal bridges and
growth of health endangering mould and mildew. In order to prevent
this problem, different numerical calculation models have been
developed. All models developed so far have a potential for
completion. The implementation of the flow-through properties of
mineral wool insulation may help to improve the existing models.
Assuming that the real pressure difference between interior and
exterior surface is larger than the prescribed pressure difference in the
standard test procedure for mineral wool ISO 9053 / EN 29053,
measurements were performed using the measurement setup for
research on convective moisture transfer “MSRCMT".
These measurements show, that structural inhomogeneities of
mineral wool effect the permeability only at higher pressure
differences, as applied in MSRCMT. Additional microscopic
investigations show, that the location of a leak within the
construction has a crucial influence on the air flow-through and the
infiltration rate. The results clearly indicate that the empirical values
for the acoustic resistance of mineral wool should not be used for the
calculation of convective transfer mechanisms.
Abstract: A subsea hydrocarbon production system can undergo planned and unplanned shutdowns during the life of the field. The thermal FEA is used to simulate the cool down to verify the insulation design of the subsea equipment, but it is also used to derive an acceptable insulation design for the cold spots. The driving factors of subsea analyses require fast responding and accurate models of the equipment cool down. This paper presents cool down analysis carried out by a Krylov subspace reduction method, and compares this approach to the commonly used FEA solvers. The model considered represents a typical component of a subsea production system, a closed valve on a dead leg. The results from the Krylov reduction method exhibits the least error and requires the shortest computational time to reach the solution. These findings make the Krylov model order reduction method very suitable for the above mentioned subsea applications.
Abstract: Partial discharge (PD) detection is an important
method to evaluate the insulation condition of metal-clad apparatus.
Non-intrusive sensors which are easy to install and have no
interruptions on operation are preferred in onsite PD detection.
However, it often lacks of accuracy due to the interferences in PD
signals. In this paper a novel PD extraction method that uses frequency
analysis and entropy based time-frequency (TF) analysis is introduced.
The repetitive pulses from convertor are first removed via frequency
analysis. Then, the relative entropy and relative peak-frequency of
each pulse (i.e. time-indexed vector TF spectrum) are calculated and
all pulses with similar parameters are grouped. According to the
characteristics of non-intrusive sensor and the frequency distribution
of PDs, the pulses of PD and interferences are separated. Finally the
PD signal and interferences are recovered via inverse TF transform.
The de-noised result of noisy PD data demonstrates that the
combination of frequency and time-frequency techniques can
discriminate PDs from interferences with various frequency
distributions.
Abstract: With the development of the Polyvinyl chloride
(PVC) products in many applications, the challenge of investigating
the raw material composition and reducing the cost have both
become more and more important. Considerable research has been
done investigating the effect of additives on the PVC products. Most
of the PVC composites research investigates only the effect of
single/few factors, at a time. This isolated consideration of the input
factors does not take in consideration the interaction effect of the
different factors. This paper implements a mixture experimental
design approach to find out a cost-effective PVC composition for the
production of electrical-insulation cables considering the ASTM
Designation (D) 6096. The results analysis showed that a minimum
cost can be achieved through using 20% virgin PVC, 18.75%
recycled PVC, 43.75% CaCO3 with participle size 10 microns, 14%
DOP plasticizer, and 3.5% CPW plasticizer. For maximum UTS the
compound should consist of: 17.5% DOP, 62.5% virgin PVC, and
20.0% CaCO3 of particle size 5 microns. Finally, for the highest
ductility the compound should be made of 35% virgin PVC, 20%
CaCO3 of particle size 5 microns, and 45.0% DOP plasticizer.