Abstract: This paper reviews the comparison of Resin Rich (RR) and Vacuum Pressure Impregnation (VPI) insulation system qualities for stator bar of rotating electrical machines. Voltage endurance and tangent delta are two diagnostic tests to determine the quality of insulation systems. The paper describes the trend of dissipation factor while performing voltage endurance test for different stator bar samples made with RR and VPI insulation system methods. Some samples were made with the same strands and insulation thickness but with different main wall material to prove the influence of insulation system methods on stator bar quality. Also, some of the samples were subjected to voltage at the temperature of their insulation class, and their dissipation factor changes were measured and studied.
Abstract: People’s tendency towards living in apartment houses is increasing in a densely populated country. However, some residents living in apartment houses are bothered by noise coming from the houses above. In order to reduce noise pollution, the communities are increasingly imposing a bylaw, including the limitation of floor impact sound, minimum thickness of floors, and floor soundproofing solutions. This research effort focused on the specific long-time deflection of resilient materials in the floor sound insulation systems of apartment houses. The experimental program consisted of testing nine floor sound insulation specimens subjected to sustained load for 45 days. Two main parameters were considered in the experimental investigation: three types of resilient materials and magnitudes of loads. The test results indicated that the structural behavior of the floor sound insulation systems under long-time load was quite different from that the systems under short-time load. The loading period increased the deflection of floor sound insulation systems and the increasing rate of the long-time deflection of the systems with ethylene vinyl acetate was smaller than that of the systems with low density ethylene polystyrene.
Abstract: Partial Discharge measurement is a very important
means of assessing the integrity of insulation systems in a High
Voltage apparatus. In compressed gas insulation systems, floating
particles can initiate partial discharge activities which adversely
affect the working of insulation. Partial Discharges below the
inception voltage also plays a crucial in damaging the integrity of
insulation over a period of time. This paper discusses the effect of
loose and fixed Copper and Nichrome wire particles on the PD
characteristics in SF6-N2 (10:90) gas mixtures at a pressure of
0.4MPa. The Partial Discharge statistical parameters and their
correlation to the observed results are discussed.
Abstract: Degradation of polymeric insulation systems of
electrical equipments increases the space charge density and the
concentration of electrical dipoles. By consequence, the maximum
values and the slopes of absorption/resorption (A/R) currents can
change with insulation systems ageing. In this paper, an analysis of
the nature of the A/R currents and the importance of their
components, especially the polarization current and the current given
by the space charge, is presented. The experimental study concerns
the A/R currents measurements of plane samples (made from
CALMICAGLAS tapes), virgin and thermally accelerated aged. The
obtained results show that the ageing process produces an increase of
the values and a decrease of shapes of the A/R currents. Finally, the
possibility of estimating insulations ageing state and lifetime from
A/R currents measurements is discussed.