Abstract: The performance of box-type solar cookers has been
reported by several researchers but little attention was paid to the
effect of the type of insulation material on the energy and exergy
efficiency of these cookers. This research aimed at evaluating the
energy and exergy efficiencies of the box-type cookers containing
different insulation materials. Energy and exergy efficiencies of five
box-type solar cookers insulated with maize cob, air (control), maize
husk, coconut coir and polyurethane foam respectively were obtained
over a period of three years. The cookers were evaluated using water
heating test procedures in determining the energy and exergy
analysis. The results were subjected to statistical analysis using
ANOVA. The result shows that the average energy input for the five
solar cookers were: 245.5, 252.2, 248.7, 241.5 and 245.5J
respectively while their respective average energy losses were: 201.2,
212.7, 208.4, 189.1 and 199.8J. The average exergy input for five
cookers were: 228.2, 234.4, 231.1, 224.4 and 228.2J respectively
while their respective average exergy losses were: 223.4, 230.6,
226.9, 218.9 and 223.0J. The energy and exergy efficiency was
highest in the cooker with coconut coir (37.35 and 3.90%
respectively) in the first year but was lowest for air (11 and 1.07%
respectively) in the third year. Statistical analysis showed significant
difference between the energy and exergy efficiencies over the years.
These results reiterate the importance of a good insulating material
for a box-type solar cooker.
Abstract: Parabolic solar trough systems have seen limited
deployments in cold northern climates as they are more suitable for
electricity production in southern latitudes. A numerical dynamic
model is developed to simulate troughs installed in cold climates and
validated using a parabolic solar trough facility in Winnipeg. The
model is developed in Simulink and will be utilized to simulate a trigeneration
system for heating, cooling and electricity generation in
remote northern communities. The main objective of this simulation
is to obtain operational data of solar troughs in cold climates and use
the model to determine ways to improve the economics and address
cold weather issues.
In this paper the validated Simulink model is applied to simulate a
solar assisted absorption cooling system along with electricity
generation using Organic Rankine Cycle (ORC) and thermal storage.
A control strategy is employed to distribute the heated oil from solar
collectors among the above three systems considering the
temperature requirements. This modelling provides dynamic
performance results using measured meteorological data recorded
every minute at the solar facility location. The purpose of this
modeling approach is to accurately predict system performance at
each time step considering the solar radiation fluctuations due to
passing clouds. Optimization of the controller in cold temperatures is
another goal of the simulation to for example minimize heat losses in
winter when energy demand is high and solar resources are low.
The solar absorption cooling is modeled to use the generated heat
from the solar trough system and provide cooling in summer for a
greenhouse which is located next to the solar field.
The results of the simulation are presented for a summer day in
Winnipeg which includes comparison of performance parameters of
the absorption cooling and ORC systems at different heat transfer
fluid (HTF) temperatures.
Abstract: In this study, the Compressive strength of concretes
made with Ground Granulated Blast furnace Slag (GGBS),
Pulverised Fuel Ash (PFA), Rice Husk Ash (RHA) and Waste Glass
Powder (WGP) after they were exposed 7800C (exposure duration of
around 60 minutes) and then allowed to cool down gradually in the
furnace for about 280 minutes at water binder ratio of 0.50 was
investigated. GGBS, PFA, RHA and WGP were used to replace up to
20% Portland cement in the control concrete. Test for the
determination of workability, compressive strength and tensile
splitting strength of the concretes were carried out and the results
were compared with control concrete. The test results showed that the
compressive strength decreased by an average of around 30% after
the concretes were exposed to the heating and cooling scenario.
Abstract: The building sector is responsible, in many
industrialized countries, for about 40% of the total energy
requirements, so it seems necessary to devote some efforts in this
area in order to achieve a significant reduction of energy
consumption and of greenhouse gases emissions.
The paper presents a study aiming at providing a design
methodology able to identify the best configuration of the system
building/plant, from a technical, economic and environmentally point
of view.
Normally, the classical approach involves a building's energy
loads analysis under steady state conditions, and subsequent selection
of measures aimed at improving the energy performance, based on
previous experience made by architects and engineers in the design
team. Instead, the proposed approach uses a sequence of two wellknown
scientifically validated calculation methods (TRNSYS and
RETScreen), that allow quite a detailed feasibility analysis.
To assess the validity of the calculation model, an existing,
historical building in Central Italy, that will be the object of
restoration and preservative redevelopment, was selected as a casestudy.
The building is made of a basement and three floors, with a
total floor area of about 3,000 square meters.
The first step has been the determination of the heating and
cooling energy loads of the building in a dynamic regime by means,
which allows simulating the real energy needs of the building in
function of its use. Traditional methodologies, based as they are on
steady-state conditions, cannot faithfully reproduce the effects of
varying climatic conditions and of inertial properties of the structure.
With this model is possible to obtain quite accurate and reliable
results that allow identifying effective combinations building-HVAC
system.
The second step has consisted of using output data obtained as
input to the calculation model, which enables to compare different
system configurations from the energy, environmental and financial
point of view, with an analysis of investment, and operation and
maintenance costs, so allowing determining the economic benefit of
possible interventions.
The classical methodology often leads to the choice of
conventional plant systems, while our calculation model provides a
financial-economic assessment for innovative energy systems and
low environmental impact.
Computational analysis can help in the design phase, particularly
in the case of complex structures with centralized plant systems, by
comparing the data returned by the calculation model for different
design options.
Abstract: Carbon Deposits are often occurred inside the
industrial coke oven during coking process. Accumulation of carbon
deposits may cause a big issue, which seriously influences the coking
operation. The carbon is burning off by injecting fresh air through
pipes into coke oven which is an efficient way practically operated in
industries. The burning off carbon deposition in coke oven performed
by Computational Fluid Dynamics (CFD) method has provided an
evaluation of the feasibility study. A three dimensional, transient,
turbulent reacting flow simulation has performed with three different
injecting air flow rate and another kind of injecting configuration. The
result shows that injection higher air flow rate would effectively
reduce the carbon deposits. In the meantime, the opened charging
holes would suck extra oxygen from atmosphere to participate in
reactions. In term of coke oven operating limits, the wall temperatures
are monitored to prevent over-heating of the adiabatic walls during
burn-off process.
Abstract: The characteristics of temperature distribution and
electric field in a natural rubber glove (NRG) using microwave
energy during microwave heating process are investigated
numerically and experimentally. A three-dimensional model of NRG
and microwave oven are considered in this work. The influences of
position, heating time and rotation angle of NRG on temperature
distribution and electric field are presented in details. The coupled
equations of electromagnetic wave propagation and heat transfer are
solved using the finite element method (FEM). The numerical model
is validated with an experimental study at a frequency of 2.45 GHz.
The results show that the numerical results closely match the
experimental results. Furthermore, it is found that the temperature
distribution and electric field increases with increasing heating time.
The hot spot zone appears in NRG at the tip of middle finger while
the maximum temperature occurs in case of rotation angle of NRG =
60 degree. This investigation provides the essential aspects for a
fundamental understanding of heat transport of NRG using
microwave energy in industry.
Abstract: At present, the cascade PID control is widely used to
control the superheating temperature (main steam temperature). As
Main Steam Temperature has the characteristics of large inertia, large
time-delay and time varying, etc., conventional PID control strategy
cannot achieve good control performance. In order to overcome the
bad performance and deficiencies of main steam temperature control
system, Model Free Adaptive Control (MFAC) - P cascade control
system is proposed in this paper. By substituting MFAC in PID of the
main control loop of the main steam temperature control, it can
overcome time delays, non-linearity, disturbance and time variation.
Abstract: Auckland has a temperate climate with comfortable warm, dry summers and mild, wet winters. An Auckland school normally does not need air conditioning for cooling during the summer and only needs heating during the winter. The Auckland school building thermal design should more focus on winter thermal performance and indoor thermal comfort for energy efficiency. This field study of testing indoor and outdoor air temperatures, relative humidity and indoor surface temperatures of three classrooms with different envelopes were carried out in the Avondale College during the winter months in 2013. According to the field study data, this study is to compare and evaluate winter thermal performance and indoor thermal conditions of school buildings with different envelopes.
Abstract: This paper presents nonlinear pulse propagation characteristics for different input optical pulse shapes with various input pulse energy levels in semiconductor optical amplifiers. For simulation of nonlinear pulse propagation, finite-difference beam propagation method is used to solve the nonlinear Schrödinger equation. In this equation, gain spectrum dynamics, gain saturation are taken into account which depends on carrier depletion, carrier heating, spectral-hole burning, group velocity dispersion, self-phase modulation and two photon absorption. From this analysis, we obtained the output waveforms and spectra for different input pulse shapes as well as for different input energies. It shows clearly that the peak position of the output waveforms are shifted toward the leading edge which due to the gain saturation of the SOA for higher input pulse energies. We also analyzed and compared the normalized difference of full-width at half maximum for different input pulse shapes in the SOA.
Abstract: This paper presents the application of the Discrete
Component Model for heating and evaporation to multi-component
biodiesel fuel droplets in direct injection internal combustion engines.
This model takes into account the effects of temperature gradient,
recirculation and species diffusion inside droplets. A distinctive
feature of the model used in the analysis is that it is based on the
analytical solutions to the temperature and species diffusion
equations inside the droplets. Nineteen types of biodiesel fuels are
considered. It is shown that a simplistic model, based on the
approximation of biodiesel fuel by a single component or ignoring
the diffusion of components of biodiesel fuel, leads to noticeable
errors in predicted droplet evaporation time and time evolution of
droplet surface temperature and radius.
Abstract: This article is deal with the experimental
investigations of the laser diode matrixes (LDM) based on the
AlGaAs/GaAs heterostructures (lasing wavelength 790-880 nm) to
find optimal LDM parameters for active vision systems. In particular,
the dependence of LDM radiation pulse power on the pulse duration
and LDA active layer heating as well as the LDM radiation
divergence are discussed.
Abstract: This work presents the result of investigations aimed
at determining the hardness of the welded Chromoly (A 4130) steel
plate of 2” thickness. Multi pass welding for the thick sections was
carried out and analyzed for the Chromoly alloy steel plates. The
study of hardness at the weld metal reveals that there is the presence
of different micro structure products which yields diverse properties.
The welding carried out using GMAW with ER70s-2 electrode.
Single V groove design was selected for the butt joint configuration.
The presence of hydrogen has been suppressed by selecting low
hydrogen electrode. Preheating of the plate prior to welding reduces
the cooling rate which also affects the weld metal microstructure. The
shielding gas composition used in this analysis is 80% Ar-20% CO2.
The experimental analysis gives the detailed study of the hardness of
the material.
Abstract: Heightened concerns over the amount of carbon
emitted from coal-related processes are generating shifts to the
application of biomass. In co-gasification, where coal is gasified
along with biomass, the biomass may be fed together with coal (cofeeding)
or an independent biomass gasifier needs to be integrated
with the coal gasifier. The main aim of this work is to evaluate the
biomass introduction methods in coal co-gasification. This includes
the evaluation of biomass concentration input (B0 to B100) and its
gasification performance. A process model is developed and
simulated in Aspen HYSYS, where both coal and biomass are
modelled according to its ultimate analysis. It was found that the
syngas produced increased with increasing biomass content for both
co-feeding and independent schemes. However, the heating values
and heat duties decreases with biomass concentration as more CO2
are produced from complete combustion.
Abstract: A single-phase closed thermosyphon has been
fabricated and experimented to utilize solar energy for water heating.
The working fluid of the closed thermosyphon is heated at the flatplate
collector and the hot water goes to the water tank due to density
gradient caused by temperature differences. This experimental work
was done using insulated water tank and insulated connecting pipe
between the tank and the flat-plate collector. From the collected data,
performance parameters such as instantaneous collector efficiency
and heat removal factor are calculated. In this study, the effects of
glazing were also observed. The water temperature rise and the
maximum instantaneous efficiency obtained from this experiment
with glazing using insulated water tank and insulated connecting pipe
are 17°C in a period of 5 hours and 60% respectively. Whereas the
water temperature rise and the maximum instantaneous efficiency
obtained from this experiment with glazing using non-insulated water
tank and non-insulated connecting pipe are 14°C in a period of 5
hours and 39% respectively.
Abstract: This research focuses on the optimization of glazed
surfaces and the assessment of possible solar gains in industrial
buildings. Existing window rating methods for single windows were
evaluated and a new method for a simple analysis of energy gains and
losses by single windows was introduced. Furthermore extensive
transient building simulations were carried out to appraise the
performance of low cost polycarbonate multi-cell sheets in
interaction with typical buildings for industrial applications. Mainly
energy saving potential was determined by optimizing the orientation
and area of such glazing systems in dependency on their thermal
qualities. Moreover the impact on critical aspects such as summer
overheating and daylight illumination was considered to ensure the
user comfort and avoid additional energy demand for lighting or
cooling. Hereby the simulated heating demand could be reduced by
up to 1/3 compared to traditional architecture of industrial halls using
mainly skylights.
Abstract: Rice straw pellets are a promising fuel as a renewable
energy source. Financial analysis is needed to make a utilization
system using rise straw pellets financially feasible, considering all
regional conditions including stakeholders related to the collection and
storage, production, transportation and heat utilization. We conducted
the financial analysis of feasibility for a heat utilization system using
rice straw pellets which has been developed for the first time in
Nanporo, Hokkaido, Japan. Especially, we attempted to clarify the
effect of factors required for the system to be financial feasibility, such
as the heating energy demand and collection and storage method of
rice straw. The financial feasibility was found to improve when
increasing the heating energy demand and collecting wheat straw in
August separately from collection of rice straw in November because
the costs of storing rice straw and producing pellets were reduced.
However, the system remained financially unfeasible. This study
proposed a contractor program funded by a subsidy from Nanporo
local government where a contracted company, instead of farmers,
collects and transports rice straw in order to ensure the financial
feasibility of the system, contributing to job creation in the region.
Abstract: In this paper we make a temperature investigations in
two type of superposed crimped connections using experimental
determinations. All the samples use 8 copper wire 7.1 x 3 mm2
crimped by two methods: the first method uses one crimp indents and
the second is a proposed method with two crimp indents. The ferrule
is a parallel one. We study the influence of number and position of
crimp indents. The samples are heated in A.C. current at different
current values until steady state heating regime. After obtaining of
temperature values, we compare them and present the conclusion.
Abstract: Heating, cooling and lighting appliances in buildings
account for more than one third of the world’s primary energy
demand. Therefore, main components of the building heating systems
play an essential role in terms of energy consumption. In this context,
efficient energy and exergy utilization in HVAC-R systems has been
very essential, especially in developing energy policies towards
increasing efficiencies. The main objective of the present study is to
assess the performance of a family house with a volume of 326.7 m3
and a net floor area of 121 m2, located in the city of Izmir, Turkey in
terms of energetic, exergetic and sustainability aspects. The indoor
and exterior air temperatures are taken as 20°C and 1°C, respectively.
In the analysis and assessment, various metrics (indices or indicators)
such as exergetic efficiency, exergy flexibility ratio and sustainability
index are utilized. Two heating options (Case 1: condensing boiler
and Case 2: air heat pump) are considered for comparison purposes.
The total heat loss rate of the family house is determined to be
3770.72 W. The overall energy efficiencies of the studied cases are
calculated to be 49.4% for Case 1 and 54.7% for Case 2. The overall
exergy efficiencies, the flexibility factor and the sustainability index
of Cases 1 and 2 are computed to be around 3.3%, 0.17 and 1.034,
respectively.
Abstract: It is known that residual welding deformations give
negative effect to processability and operational quality of welded
structures, complicating their assembly and reducing strength.
Therefore, selection of optimal technology, ensuring minimum
welding deformations, is one of the main goals in developing a
technology for manufacturing of welded structures.
Through years, JSC SSTC has been developing a theory for
estimation of welding deformations and practical activities for
reducing and compensating such deformations during welding
process. During long time a methodology was used, based on analytic
dependence. This methodology allowed defining volumetric changes
of metal due to welding heating and subsequent cooling. However,
dependences for definition of structures deformations, arising as a
result of volumetric changes of metal in the weld area, allowed
performing calculations only for simple structures, such as units, flat
sections and sections with small curvature. In case of complex 3D
structures, estimations on the base of analytic dependences gave
significant errors.
To eliminate this shortage, it was suggested to use finite elements
method for resolving of deformation problem. Here, one shall first
calculate volumes of longitudinal and transversal shortenings of
welding joints using method of analytic dependences and further,
with obtained shortenings, calculate forces, which action is
equivalent to the action of active welding stresses. Further, a finiteelements
model of the structure is developed and equivalent forces
are added to this model. Having results of calculations, an optimal
sequence of assembly and welding is selected and special measures to
reduce and compensate welding deformations are developed and
taken.
Abstract: Biomass is renewable and sustainable. As an energy source, it will not release extra carbon dioxide into the atmosphere. Hence, tremendous efforts have been made to develop technologies capable of transforming biomass into suitable forms of bio-fuel. One of the viable technologies is gasifying biomass in supercritical water (SCW), a green medium for reactions. While previous studies overwhelmingly selected glucose as a model compound for biomass, the present study adopted fructose for the sake of comparison. The gasification of fructose in SCW was investigated experimentally to evaluate the applicability of supercritical water processes to biomass gasification. Experiments were conducted with an autoclave reactor. Gaseous product mainly consists of H2, CO, CO2, CH4 and C2H6. The effect of two major operating parameters, the reaction temperature (673-873 K) and the dosage of oxidizing agent (0-0.5 stoichiometric oxygen), on the product gas composition, yield and heating value was also examined, with the reaction pressure fixed at 25 MPa.