Abstract: Objective: Acute coronary syndrome is a clinical
condition encompassing ST segments elevation myocardial
infraction, Non ST segment is elevation myocardial infraction and un
stable angina is characterized by ruptured coronary plaque, stress and
myocardial injury. Angina pectoris is a pressure like pain in the chest
that is induced by exertion or stress and relived with in the minute
after cessation of effort or using sublingual nitroglycerin. The present
research was undertaken to study the drug utilization pattern of
antiplatelet drugs for the ischemic heart disease in a tertiary care
hospital. Method: The present study is retrospective drug utilization
study and study period is 6months. The data is collected from the
discharge case sheet of general medicine department from medical
department Rajiv Gandhi institute of medical sciences, Kadapa. The
tentative sample size fixed was 250 patients. Out of 250 cases 19
cases was excluded because of unrelated data. Results: A total of 250
prescriptions were collected for the study according to the inclusion
criteria 233 prescriptions were diagnosed with ischemic heart disease
17 prescriptions were excluded due to unrelated information. out of
233 prescriptions 128 are male (54.9%) and 105 patients are were
female (45%). According to the gender distribution, the prevalence of
ischemic heart disease in males are 90 (70.31%) and females are 39
(37.1%). In the same way the prevalence of ischemic heart disease
along with cerebrovascular disease in males are 39 (29.6%) and
females are 66 (62.6%). Conclusion: We found that 94.8% of drug
utilization of antiplatelet drugs was achieved in the Rajiv Gandhi
institute of medical sciences, Kadapa from 2011-2012.
Abstract: This paper aims to analysis the behavior of DC corona
discharge in wire-to-plate electrostatic precipitators (ESP). Currentvoltage
curves are particularly analyzed. Experimental results show
that discharge current is strongly affected by the applied voltage. The proposed method of current identification is to use the method
of least squares. Least squares problems that of into two categories:
linear or ordinary least squares and non-linear least squares,
depending on whether or not the residuals are linear in all unknowns.
The linear least-squares problem occurs in statistical regression
analysis; it has a closed-form solution. A closed-form solution (or
closed form expression) is any formula that can be evaluated in a
finite number of standard operations. The non-linear problem has no
closed-form solution and is usually solved by iterative.
Abstract: The main purpose of this study is to assess the
sediment quality and potential ecological risk in marine sediments in
Gymea Bay located in south Sydney, Australia. A total of 32 surface
sediment samples were collected from the bay. Current track
trajectories and velocities have also been measured in the bay. The
resultant trace elements were compared with the adverse biological
effect values Effect Range Low (ERL) and Effect Range Median
(ERM) classifications. The results indicate that the average values of
chromium, arsenic, copper, zinc, and lead in surface sediments all
reveal low pollution levels and are below ERL and ERM values. The
highest concentrations of trace elements were found close to
discharge points and in the inner bay, and were linked with high
percentages of clay minerals, pyrite and organic matter, which can
play a significant role in trapping and accumulating these elements.
The lowest concentrations of trace elements were found to be on the
shoreline of the bay, which contained high percentages of sand
fractions. It is postulated that the fine particles and trace elements are
disturbed by currents and tides, then transported and deposited in
deeper areas. The current track velocities recorded in Gymea Bay had
the capability to transport fine particles and trace element pollution
within the bay. As a result, hydrodynamic measurements were able to
provide useful information and to help explain the distribution of
sedimentary particles and geochemical properties. This may lead to
knowledge transfer to other bay systems, including those in remote
areas. These activities can be conducted at a low cost, and are
therefore also transferrable to developing countries. The advent of
portable instruments to measure trace elements in the field has also
contributed to the development of these lower cost and easily applied
methodologies available for use in remote locations and low-cost
economies.
Abstract: Laura Island, which is located about 50 km away from
downtown, is a source of water supply in Majuro atoll, which is the
capital of the Republic of the Marshall Islands. Low and flat Majuro
atoll has neither river nor lake. It is very important for Majuro atoll to
ensure the conservation of its water resources. However, upconing,
which is the process of partial rising of the freshwater-saltwater
boundary near the water-supply well, was caused by the excess
pumping from it during the severe drought in 1998. Upconing will
make the water usage of the freshwater lens difficult. Thus,
appropriate water usage is required to prevent up coning in the
freshwater lens because there is no other water source during drought. Numerical simulation of water usage applying SEAWAT model
was conducted at the central part of Laura Island, including the water
supply well, which was affected by upconing. The freshwater lens was
created as a result of infiltration of consistent average rainfall. The lens
shape was almost the same as the one in 1985. 0 of monthly rainfall
and variable daily pump discharge were used to calculate the
sustainable pump discharge from the water supply well. Consequently,
the total amount of pump discharge was increased as the daily pump
discharge was increased, indicating that it needs more time to recover
from upconing. Thus, a pump standard to reduce the pump intensity is
being proposed, which is based on numerical simulation concerning
the occurrence of the up-coning phenomenon in Laura Island during
the drought.
Abstract: Within this paper, latest results on processing of energetic nanomaterials by means of the Spray Flash Evaporation technique are presented. This technology constitutes a highly effective and continuous way to prepare fascinating materials on the nano- and micro-scale. Within the process, a solution is set under high pressure and sprayed into an evacuated atomization chamber. Subsequent ultrafast evaporation of the solvent leads to an aerosol stream, which is separated by cyclones or filters. No drying gas is required, so the present technique should not be confused with spray dying. Resulting nanothermites, insensitive explosives or propellants and compositions are foreseen to replace toxic (according to REACH) and very sensitive matter in military and civil applications. Diverse examples are given in detail: nano-RDX (n-Cyclotrimethylentrinitramin) and nano-aluminum based systems, mixtures (n-RDX/n-TNT - trinitrotoluene) or even cocrystalline matter like n-CL-20/HMX (Hexanitrohexaazaisowurtzitane/ Cyclotetra-methylentetranitramin). These nanomaterials show reduced sensitivity by trend without losing effectiveness and performance. An analytical study for material characterization was performed by using Atomic Force Microscopy, X-Ray Diffraction, and combined techniques as well as spectroscopic methods. As a matter of course, sensitivity tests regarding electrostatic discharge, impact, and friction are provided.
Abstract: The post-rain puddles problem that occurs in the first
yard of Prambanan Temple are often disturbing visitor activity. A
poodle layer and a drainage system had ever built to avoid such a
problem, but puddles still did not stop appearing after rain.
Permeability parameter needs to be determined by using a simpler
procedure to find exact method of solution. The instrument modelling
was proposed according to the development of field permeability
testing instrument. This experiment used a proposed Constant
Discharge method. Constant Discharge method used a tube poured
with constant water flow from unsaturated until saturated soil
condition. Volumetric water content (θ) were monitored by soil
moisture measurement device. The results were correlations between
k and θ which were drawn by numerical approach from Van
Genutchen model. Parameters θr optimum value obtained from the
test was at very dry soil. Coefficient of permeability with a density of
19.8 kN/m3 for unsaturated conditions was in range of 3 x 10-6
cm/sec (Sr=68%) until 9.98 x 10-4 cm/sec (Sr=82%). The equipment
and testing procedure developed in this research was quite effective,
simple and easy to be implemented on determining field soil
permeability coefficient value of sandy soil. Using constant discharge
method in proposed permeability test, value of permeability
coefficient under unsaturated condition can be obtained without
establish soil water characteristic curve.
Abstract: The current statuses of lifetime test of LaB6 hollow
cathode at the Lanzhou Institute of Physics (LIP), China, was
described. 5A LaB6 hollow cathode was design for LIPS-200 40mN
Xenon ion thruster, and it could be used for LHT-100 80 mN Hall
thruster, too. Life test of the discharge and neutralizer modes of LHC-5
hollow cathode were stared in October 2011, and cumulative operation
time reached 17,300 and 16,100 hours in April 2015, respectively. The
life of cathode was designed more than 11,000 hours. Parameters of
discharge and key structure dimensions were monitored in different
stage of life test indicated that cathodes were health enough. The test
will continue until the cathode cannot work or operation parameter is
not in normally. The result of the endurance test of cathode
demonstrated that the LaB6 hollow cathode is satisfied for the required
of thruster in life and performance.
Abstract: This study aims at improving the urban hydrological
cycle of the Orléans agglomeration (France) and understanding the
relationship between physical and chemical parameters of urban
surface runoff and the hydrological conditions. In particular water
quality parameters such as pH, conductivity, total dissolved solids,
major dissolved cations and anions, and chemical and biological
oxygen demands were monitored for three types of urban water
discharges (wastewater treatment plant output (WWTP), storm
overflow and stormwater outfall) under two hydrologic scenarios (dry
and wet weather). The first results were obtained over a period of five
months. Each investigated (Ormes, l’Egoutier and La Corne) outfall
represents an urban runoff source that receives water from runoff
roads, gutters, the irrigation of gardens and other sources of flow over
the Earth’s surface that drains in its catchments and carries it to the
Loire River. In wet weather conditions there is rain water runoff and
an additional input from the roof gutters that have entered the
stormwater system during rainfall. For the comparison the results La
Chilesse is a storm overflow that was selected in our study as a
potential source of waste water which is located before the (WWTP). The comparison of the physical-chemical parameters (total
dissolved solids, turbidity, pH, conductivity, dissolved organic
carbon (DOC), concentration of major cations and anions) together
with the chemical oxygen demand (COD) and biological oxygen
demand (BOD) helped to characterize sources of runoff waters in the
different watersheds. It also helped to highlight the infiltration of
wastewater in some stormwater systems that reject directly in the
Loire River. The values of the conductivity measured in the outflow
of Ormes were always higher than those measured in the other two
outlets. The results showed a temporal variation for the Ormes outfall
of conductivity from 1465 μS cm-1 in the dry weather flow to 650 μS
cm-1 in the wet weather flow and also a spatial variation in the wet
weather flow from 650 μS cm-1 in the Ormes outfall to 281 μS cm-1
in L’Egouttier outfall. The ultimate BOD (BOD28) showed a
significant decrease in La Corne outfall from 181 mg L-1 in the wet
weather flow to 95 mg L-1 in the dry weather flow because of the
nutrient load that was transported by the runoff.
Abstract: This study and the field test comparisons were carried
out on the Algerian Derguna – Setif transmission systems. The
transmission line of normal voltage 225 kV is 65 km long,
transported and uses twin bundle conductors protected with two
shield wires of transposed galvanized steel. An iterative finite-element method is used to solve Poisons
equation. Two algorithms are proposed for satisfying the current
continuity condition and updating the space-charge density. A new approach to the problem of corona discharge in
transmission system has been described in this paper. The effect of
varying the configurations and wires number is also investigated. The
analysis of this steady is important in the design of HVDC
transmission lines. The potential and electric field have been
calculating in locations singular points of the system.
Abstract: Mineral oil is commonly used for high voltage
transformer insulation. The insulation quality of mineral oil is
affecting the operation process of high voltage transformer. There are
many contaminations which could decrease the insulation quality of
mineral oil. One of them is water. This research talks about the effect
of water content on dielectric properties, physic properties, and
partial discharge pattern on mineral oil. Samples were varied with 10
varieties of water content value. And then all samples would be tested
to measure the dielectric properties, physic properties, and partial
discharge pattern. The result of this research showed that an
increment of water content value would decrease the insulation
quality of mineral oil.
Abstract: Piezoelectric actuator is treated as RC load when it is
modeled electrically. For some piezoelectric actuator applications,
arbitrary voltage is required to actuate. Especially for unidirectional
arbitrary voltage driving like as sine wave, some special inverter with
circuit that can charge and discharge the capacitive energy can be
used. In this case, the difference between power supply level and the
object voltage level for RC load is varied. Because the control gain is
constant, the controlled output is not uniform according to the voltage
difference. In this paper, for charge and discharge circuit for
unidirectional arbitrary voltage driving for piezoelectric actuator, the
controller gain is controlled according to the voltage difference. With
the proposed simple idea, the load voltage can have controlled
smoothly although the voltage difference is varied. The
appropriateness is proved from the simulation of the proposed circuit.
Abstract: Wire Electric Discharge Machining (WEDM) is
thermal machining process capable of machining very hard
electrically conductive material irrespective of their hardness.
WEDM is being widely used to machine micro scale parts with the
high dimensional accuracy and surface finish. The objective of this
paper is to optimize the process parameters of wire EDM to fabricate
the micro channels and to calculate the surface finish and material
removal rate of micro channels fabricated using wire EDM. The
material used is aluminum 6061 alloy. The experiments were
performed using CNC wire cut electric discharge machine. The effect
of various parameters of WEDM like pulse on time (TON) with the
levels (100, 150, 200), pulse off time (TOFF) with the levels (25, 35,
45) and current (IP) with the levels (105, 110, 115) were investigated
to study the effect on output parameter i.e. Surface Roughness and
Material Removal Rate (MRR). Each experiment was conducted
under different conditions of pulse on time, pulse off time and peak
current. For material removal rate, TON and Ip
were the most significant process parameter. MRR increases with the increase in
TON and Ip and decreases with the increase in TOFF. For surface
roughness, TON and Ip have the maximum effect and TOFF was found
out to be less effective.
Abstract: The current tools for real time management of sewer
systems are based on two software tools: the software of weather
forecast and the software of hydraulic simulation. The use of the first
ones is an important cause of imprecision and uncertainty, the use of
the second requires temporal important steps of decision because of
their need in times of calculation. This way of proceeding fact that
the obtained results are generally different from those waited. The major idea of this project is to change the basic paradigm by
approaching the problem by the "automatic" face rather than by that
"hydrology". The objective is to make possible the realization of a
large number of simulations at very short times (a few seconds)
allowing to take place weather forecasts by using directly the real
time meditative pluviometric data. The aim is to reach a system
where the decision-making is realized from reliable data and where
the correction of the error is permanent. A first model of control laws was realized and tested with different
return-period rainfalls. The gains obtained in rejecting volume vary
from 19 to 100 %. The development of a new algorithm was then
used to optimize calculation time and thus to overcome the
subsequent combinatorial problem in our first approach. Finally, this
new algorithm was tested with 16- year-rainfall series. The obtained
gains are 40 % of total volume rejected to the natural environment
and of 65 % in the number of discharges.
Abstract: Present study was aimed to develop a discharge
measuring device for irrigation and laboratory channels. Experiments
were conducted on sharp edged constricted flow meters having four
types of width constrictions namely 2:1, 1.5:1, 1:1 and 90o in the
direction of flow. These devices were made of MS sheets and
installed separately in a rectangular flume. All these four devices
were tested under free and submerged flow conditions. Eight
different discharges varying from 2 lit/sec to 30 lit/sec were passed
through each device. In total around 500 observations of upstream
and downstream depths were taken in the present work. For each
discharge, free submerged and critical submergence under different
flow conditions were noted and plotted. Once the upstream and
downstream depths of flow over any of the device are known, the
discharge can be easily calculated with the help of the curves
developed for free and submerged flow conditions. The device
having contraction 2:1 is the most efficient one as it allows maximum
critical submergence.
Abstract: The present paper attempts to investigate the
prediction of air entrainment rate and aeration efficiency of a free
overfall jets issuing from a triangular sharp crested weir by using
regression based modelling. The empirical equations, Support vector
machine (polynomial and radial basis function) models and the linear
regression techniques were applied on the triangular sharp crested
weirs relating the air entrainment rate and the aeration efficiency to
the input parameters namely drop height, discharge, and vertex angle.
It was observed that there exists a good agreement between the
measured values and the values obtained using empirical equations,
Support vector machine (Polynomial and rbf) models and the linear
regression techniques. The test results demonstrated that the SVM
based (Poly & rbf) model also provided acceptable prediction of the
measured values with reasonable accuracy along with empirical
equations and linear regression techniques in modelling the air
entrainment rate and the aeration efficiency of a free overfall jets
issuing from triangular sharp crested weir. Further sensitivity analysis
has also been performed to study the impact of input parameter on the
output in terms of air entrainment rate and aeration efficiency.
Abstract: The application of cold Radio-Frequency (RF) plasma
in the conservation of cultural heritage became important in the last
decades due to the positive results obtained in decontamination
treatments. This paper presents an equipment especially designed for cold RF
plasma application on paper documents, developed within a research
project. The equipment consists in two modules: the first one is
designed for decontamination and cleaning treatments of any type of
paper supports, while the second one can be used for coating friable
papers with adequate polymers, for protection purposes. All these
operations are carried out in cold radio-frequency plasma, working in
gaseous nitrogen, at low pressure. In order to optimize the equipment parameters ancient paper
samples infested with microorganisms have been treated in nitrogen
plasma and the decontamination effects, as well as changes in surface
properties (color, pH) were assessed. The microbiological analysis
revealed complete decontamination at 6 minutes treatment duration;
only minor modifications of the surface pH were found and the
colorimetric analysis showed a slight yellowing of the support.
Abstract: Industries produce millions of cubic meters of effluent
every year and the wastewater produced may be released into the
surrounding water bodies, treated on-site or at municipal treatment
plants. The determination of organic matter in the wastewater
generated is very important to avoid any negative effect on the
aquatic ecosystem. The scope of the present work is to assess the
physicochemical composition of the wastewater produced from one
of the brewery industry in South Africa. This is to estimate the
environmental impact of its discharge into the receiving water bodies
or the municipal treatment plant. The parameters monitored for the
quantitative analysis of brewery wastewater include biological
oxygen demand (BOD5), chemical oxygen demand (COD), total
suspended solids, volatile suspended solids, ammonia, total oxidized
nitrogen, nitrate, nitrite, phosphorus and alkalinity content. In
average, the COD concentration of the brewery effluent was 5340.97
mg/l with average pH values of 4.0 to 6.7. The BOD5 and the solids
content of the wastewater from the brewery industry were high. This
means that the effluent is very rich in organic content and its
discharge into the water bodies or the municipal treatment plant could
cause environmental pollution or damage the treatment plant. In
addition, there were variations in the wastewater composition
throughout the monitoring period. This might be as a result of
different activities that take place during the production process, as
well as the effects of peak period of beer production on the water
usage.
Abstract: Distillery spentwash contains high chemical oxygen
demand (COD), biological oxygen demand (BOD), color, total
dissolved solids (TDS) and other contaminants even after biological
treatment. The effluent can’t be discharged as such in the surface
water bodies or land without further treatment. Reverse osmosis (RO)
treatment plants have been installed in many of the distilleries at
tertiary level in many of the distilleries in India, but are not properly
working due to fouling problem which is caused by the presence of
high concentration of organic matter and other contaminants in
biologically treated spentwash. In order to make the membrane
treatment a proven and reliable technology, proper pre-treatment is
mandatory. In the present study, ultra-filtration (UF) for pretreatment
of RO at tertiary stage has been performed. Operating
parameters namely initial pH (pHo: 2–10), trans-membrane pressure
(TMP: 4-20 bars) and temperature (T: 15-43°C) were used for
conducting experiments with UF system. Experiments were
optimized at different operating parameters in terms of COD, color,
TDS and TOC removal by using response surface methodology
(RSM) with central composite design. The results showed that
removal of COD, color and TDS was 62%, 93.5% and 75.5%
respectively, with UF, at optimized conditions with increased
permeate flux from 17.5 l/m2/h (RO) to 38 l/m2/h (UF-RO). The
performance of the RO system was greatly improved both in term of
pollutant removal as well as water recovery.
Abstract: The goal of this experiment is to evaluate the
effectiveness of different leachate pre-treatment options in terms of
COD and ammonia removal. This research focused on the evaluation
of physical-chemical methods for pre-treatment of leachate that
would be effective and rapid in order to satisfy the requirements of
the sewer discharge by-laws. The four pre-treatment options
evaluated were: air stripping, chemical coagulation, electrocoagulation
and advanced oxidation with sodium ferrate. Chemical
coagulation reported the best COD removal rate at 43%, compared to
18% for both air stripping and electro-coagulation, and 20% for
oxidation with sodium ferrate. On the other hand, air stripping was
far superior to the other treatment options in terms of ammonia
removal with 86%. Oxidation with sodium ferrate reached only 16%,
while chemical coagulation and electro-coagulation removed less
than 10%. When combined, air stripping and chemical coagulation
removed up to 50% COD and 85% ammonia.
Abstract: Waste Load Allocation (WLA) strategies usually
intend to find economic policies for water resource management.
Water quality trading (WQT) is an approach that uses discharge
permit market to reduce total environmental protection costs. This
primarily requires assigning discharge limits known as total
maximum daily loads (TMDLs). These are determined by monitoring
organizations with respect to the receiving water quality and
remediation capabilities. The purpose of this study is to compare two
approaches of TMDL assignment for WQT policy in small catchment
area of Haraz River, in north of Iran. At first, TMDLs are assigned
uniformly for the whole point sources to keep the concentrations of
BOD and dissolved oxygen (DO) at the standard level at checkpoint
(terminus point). This was simply simulated and controlled by
Qual2kw software. In the second scenario, TMDLs are assigned
using multi objective particle swarm optimization (MOPSO) method
in which the environmental violation at river basin and total treatment
costs are minimized simultaneously. In both scenarios, the equity
index and the WLA based on trading discharge permits (TDP) are
calculated. The comparative results showed that using economically
optimized TMDLs (2nd scenario) has slightly more cost savings rather
than uniform TMDL approach (1st scenario). The former annually
costs about 1 M$ while the latter is 1.15 M$. WQT can decrease
these annual costs to 0.9 and 1.1 M$, respectively. In other word,
these approaches may save 35 and 45% economically in comparison
with command and control policy. It means that using multi objective
decision support systems (DSS) may find more economical WLA,
however its outcome is not necessarily significant in comparison with
uniform TMDLs. This may be due to the similar impact factors of
dischargers in small catchments. Conversely, using uniform TMDLs
for WQT brings more equity that makes stakeholders not feel that
much envious of difference between TMDL and WQT allocation. In
addition, for this case, determination of TMDLs uniformly would be
much easier for monitoring. Consequently, uniform TMDL for TDP
market is recommended as a sustainable approach. However,
economical TMDLs can be used for larger watersheds.