Abstract: Alongside the rapid expansion of Seawater Reverse Osmosis technologies there is a concurrent increase in the production of hypersaline brine by-products. To minimize environmental impact, these by-products are commonly disposed into open-coastal environments via submerged diffuser systems as inclined dense jet outfalls. Despite the widespread implementation of this process, diffuser designs are typically based on small-scale laboratory experiments under idealistic quiescent conditions. Studies concerning diffuser performance in the field are limited. A set of experiments were conducted to assess the near field characteristics of brine disposal at the Gold Coast Desalination Plant offshore multiport diffuser. The aim of the field experiments was to determine the trajectory and dilution characteristics of the plume under various discharge configurations with production ranging 66 – 100% of plant operative capacity. The field monitoring system employed an unprecedented static array of temperature and electrical conductivity sensors in a three-dimensional grid surrounding a single diffuser port. Complimenting these measurements, Acoustic Doppler Current Profilers were also deployed to record current variability over the depth of the water column and wave characteristics. Recorded data suggested the open-coastal environment was highly active over the experimental duration with ambient velocities ranging 0.0 – 0.5 m∙s-1, with considerable variability over the depth of the water column observed. Variations in background electrical conductivity corresponding to salinity fluctuations of ± 1.7 g∙kg-1 were also observed. Increases in salinity were detected during plant operation and appeared to be most pronounced 10 – 30 m from the diffuser, consistent with trajectory predictions described by existing literature. Plume trajectories and respective dilutions extrapolated from salinity data are compared with empirical scaling arguments. Discharge properties were found to adequately correlate with modelling projections. Temporal and spatial variation of background processes and their subsequent influence upon discharge outcomes are discussed with a view to incorporating the influence of waves and ambient currents in the design of brine outfalls into the future.
Abstract: The subject of this paper is the investigation of the
best efficiency design of a compressor diffuser applied in new
lightweight, ultra efficient micro-gas turbine engines for vehicles. The
Computational Fluid Dynamics (CFD) results are obtained utilizing
steady state simulations for a wedge and an ”oval” type pipe diffuser
in an effort to identify the beneficial effects of the pipe diffuser
design. The basic flow features are presented with particular focus
on the optimization of the pipe diffuser leading to higher efficiencies
for the compressor stage. The optimised pipe diffuser is designed to
exploit the 3D freedom enabled by Selective Laser Melting, hence
purposely involves an investigation of geometric characteristics that
do not follow the traditional diffuser concept.
Abstract: Temperature distribution investigation in a conical diffuser fitted with helical screw-tape with and without center-rod is studied numerically. A helical screw-tape is inserted in the diffuser to create swirl flow that helps to enhance the temperature distribution rate with inlet Reynolds number 4.3 x 104. Three pitch lengths ratios (Y/L = 0.153, 0.23 and 0.307) for the helical screw-tape with and without center-rod are simulated and compared. The geometry of the conical diffuser and the inlet condition for both arrangements are kept constant. Numerical findings show that the helical screw-tape inserts without center-rod perform significantly better than the helical tape inserts with center-rod in the conical diffuser.
Abstract: Universal modeling method well proven for industrial
compressors was applied for design of the high flow rate supersonic
stage. Results were checked by ANSYS CFX and NUMECA Fine
Turbo calculations. The impeller appeared to be very effective at
transonic flow velocities. Stator elements efficiency is acceptable at
design Mach numbers too. Their loss coefficient versus inlet flow
angle performances correlates well with Universal modeling
prediction. The impeller demonstrates ability of satisfactory operation
at design flow rate. Supersonic flow behavior in the impeller inducer
at the shroud blade to blade surface Φ des deserves additional study.
Abstract: In this paper the supersonic ejectors are
experimentally and analytically studied. Ejector is a device that
uses the energy of a fluid to move another fluid. This device works
like a vacuum pump without usage of piston, rotor or any other
moving component. An ejector contains an active nozzle, a passive
nozzle, a mixing chamber and a diffuser. Since the fluid viscosity
is large, and the flow is turbulent and three dimensional in the
mixing chamber, the numerical methods consume long time and
high cost to analyze the flow in ejectors. Therefore this paper
presents a simple analytical method that is based on the precise
governing equations in fluid mechanics. According to achieved
analytical relations, a computer code has been prepared to analyze
the flow in different components of the ejector. An experiment has
been performed in supersonic regime 1.5
Abstract: The article deals with experimental and numerical
investigation of axi-symmetric subsonic air to air ejector with
diffuser adapted for boundary layer suction. The diffuser, which is
placed behind the mixing chamber of the ejector, has high divergence
angle and therefore low efficiency. To increase the efficiency, the
diffuser is equipped with slot enabling boundary layer suction. The
effect of boundary layer suction on flow in ejector, static pressure
distribution on the mixing chamber wall and characteristic were
measured and studied numerically. Both diffuser and ejector
efficiency were evaluated. The diffuser efficiency was increased,
however, the efficiency of ejector itself remained low.
Abstract: This paper presents a computational study of the separated flow in a planer asymmetric diffuser. The steady RANS equations for turbulent incompressible fluid flow and six turbulence closures are used in the present study. The commercial software code, FLUENT 6.3.26, was used for solving the set of governing equations using various turbulence models. Five of the used turbulence models are available directly in the code while the v2-f turbulence model was implemented via User Defined Scalars (UDS) and User Defined Functions (UDF). A series of computational analysis is performed to assess the performance of turbulence models at different grid density. The results show that the standard k-ω, SST k-ω and v2-f models clearly performed better than other models when an adverse pressure gradient was present. The RSM model shows an acceptable agreement with the velocity and turbulent kinetic energy profiles but it failed to predict the location of separation and attachment points. The standard k-ε and the low-Re k- ε delivered very poor results.
Abstract: Aircraft propulsion systems often use Y-shaped
subsonic diffusing ducts as twin air-intakes to supply the ambient air
into the engine compressor for thrust generation. Due to space
constraint, the diffusers need to be curved, which causes severe flow
non-uniformity at the engine face. The present study attempt to
control flow in a mild-curved Y-duct diffuser using trapezoidalshaped
vortex generators (VG) attached on either both the sidewalls
or top and bottom walls of the diffuser at the inflexion plane. A
commercial computational fluid dynamics (CFD) code is modified
and is used to simulate the effects of SVG in flow of a Y-duct
diffuser. A few experiments are conducted for CFD code validation,
while the rest are done computationally. The best combination of Yduct
diffuser is found with VG-2 arranged in co-rotating sequence
and attached to both the sidewalls, which ensures highest static
pressure recovery, lowest total pressure loss, minimum flow
distortion and less flow separation in Y-duct diffuser. The decrease in
VG height while attached to top and bottom walls further improves
axial flow uniformity at the diffuser outlet by a great margin as
compared to the bare duct.
Abstract: The operation performance of a valveless micro-pump
is strongly dependent on the shape of connected nozzle/diffuser and
Reynolds number. The aims of present work are to compare the
performance curves of micropump with the original straight
nozzle/diffuser and contoured nozzle/diffuser under different back
pressure conditions. The tested valveless micropumps are assembled
of five pieces of patterned PMMA plates with hot-embracing
technique. The structures of central chamber, the inlet/outlet
reservoirs and the connected nozzle/diffuser are fabricated with laser
cutting machine. The micropump is actuated with circular-type PZT
film embraced on the bottom of central chamber. The deformation of
PZT membrane with various input voltages is measured with a
displacement laser probe. A simple testing facility is also constructed
to evaluate the performance curves for comparison.
In order to observe the evaluation of low Reynolds number
multiple vortex flow patterns within the micropump during suction
and pumping modes, the unsteady, incompressible laminar
three-dimensional Reynolds-averaged Navier-Stokes equations are
solved. The working fluid is DI water with constant thermo-physical
properties. The oscillating behavior of PZT film is modeled with the
moving boundary wall in way of UDF program. With the dynamic
mesh method, the instants pressure and velocity fields are obtained
and discussed.Results indicated that the volume flow rate is not
monotony increased with the oscillating frequency of PZT film,
regardless of the shapes of nozzle/diffuser. The present micropump
can generate the maximum volume flow rate of 13.53 ml/min when
the operation frequency is 64Hz and the input voltage is 140 volts.
The micropump with contoured nozzle/diffuser can provide 7ml/min
flow rate even when the back pressure is up to 400 mm-H2O. CFD
results revealed that the flow central chamber was occupied with
multiple pairs of counter-rotating vortices during suction and
pumping modes. The net volume flow rate over a complete
oscillating periodic of PZT
Abstract: This paper investigates experimental and numerical study of the airflow characteristics for vortex, round and square ceiling diffusers and its effect on the thermal comfort in a ventilated room. Three different thermal comfort criteria namely; Mean Age of the Air (MAA), ventilation effectiveness (E), and Effective Draft Temperature (EDT) have been used to predict the thermal comfort zone inside the room. In experimental work, a sub-scale room is set-up to measure the temperature field in the room. In numerical analysis, unstructured grids have been used to discretize the numerical domain. Conservation equations are solved using FLUENT commercial flow solver. The code is validated by comparing the numerical results obtained from three different turbulence models with the available experimental data. The comparison between the various numerical models shows that the standard k-ε turbulence model can be used to simulate these cases successfully. After validation of the code, effect of supply air velocity on the flow and thermal field could be investigated and hence the thermal comfort. The results show that the pressure coefficient created by the square diffuser is 1.5 times greater than that created by the vortex diffuser. The velocity decay coefficient is nearly the same for square and round diffusers and is 2.6 times greater than that for the vortex diffuser.
Abstract: This paper reports on the results of experimental investigations on the performance of a jet pump operated under selected primary flows to optimize the related parameters. For this purpose a two-phase flow jet pump was used employing various profiles of nozzles as the primary device which was designed, fabricated and used along with the combination of mixing tube and diffuser. The profiles employed were circular, conical, and elliptical. The diameter of the nozzle used was 4 mm. The area ratio of the jet pump was 0.16. The test facility created for this purpose was an open loop continuous circulation system. Performance of the jet pump was obtained as iso-efficiency curves on characteristic curves drawn for various water flow rates. To perform the suction capability, evacuation test was conducted at best efficiency point for all the profiles.
Abstract: The flow field in a centrifugal fan is highly complex
with flow reversal taking place on the suction side of impeller and
diffuser vanes. Generally performance of the centrifugal fan could be
enhanced by judiciously introducing splitter vanes so as to improve
the diffusion process. An extensive numerical whole field analysis on
the effect of splitter vanes placed in discrete regions of suspected
separation points is possible using CFD. This paper examines the
effect of splitter vanes corresponding to various geometrical
locations on the impeller and diffuser. The analysis shows that the
splitter vanes located near the diffuser exit improves the static
pressure recovery across the diffusing domain to a larger extent. Also
it is found that splitter vanes located at the impeller trailing edge and
diffuser leading edge at the mid-span of the circumferential distance
between the blades show a marginal improvement in the static
pressure recovery across the fan. However, splitters provided near to
the suction side of the impeller trailing edge (25% of the
circumferential gap between the impeller blades towards the suction
side), adversely affect the static pressure recovery of the fan.