Abstract: A loading factor performance is necessary for the modeling of centrifugal compressor gas dynamic performance curve. Measured loading factors are linear function of a flow coefficient at an impeller exit. The performance does not depend on the compressibility criterion. To simulate loading factor performances, the authors present two parameters: a loading factor at zero flow rate and an angle between an ordinate and performance line. The calculated loading factor performances of non-viscous are linear too and close to experimental performances. Loading factor performances of several dozens of impellers with different blade exit angles, blade thickness and number, ratio of blade exit/inlet height, and two different type of blade mean line configuration. There are some trends of influence, which are evident – comparatively small blade thickness influence, and influence of geometry parameters is more for impellers with bigger blade exit angles, etc. Approximating equations for both parameters are suggested. The next phase of work will be simulating of experimental performances with the suggested approximation equations as a base.
Abstract: The 6th version of Universal modeling method for
centrifugal compressor stage calculation is described. Identification
of the new mathematical model was made. As a result of
identification the uniform set of empirical coefficients is received.
The efficiency definition error is 0,86 % at a design point. The
efficiency definition error at five flow rate points (except a point of
the maximum flow rate) is 1,22 %. Several variants of the stage with
3D impellers designed by 6th version program and quasi threedimensional
calculation programs were compared by their gas
dynamic performances CFD (NUMECA FINE TURBO).
Performance comparison demonstrated general principles of design
validity and leads to some design recommendations.
Abstract: Universal modeling method well proven for industrial
compressors was applied for design of the high flow rate supersonic
stage. Results were checked by ANSYS CFX and NUMECA Fine
Turbo calculations. The impeller appeared to be very effective at
transonic flow velocities. Stator elements efficiency is acceptable at
design Mach numbers too. Their loss coefficient versus inlet flow
angle performances correlates well with Universal modeling
prediction. The impeller demonstrates ability of satisfactory operation
at design flow rate. Supersonic flow behavior in the impeller inducer
at the shroud blade to blade surface Φ des deserves additional study.