Abstract: Industrial Control Systems (ICS) such as Supervisory Control And Data Acquisition (SCADA) can be seen in many different critical infrastructures, from nuclear management to utility, medical equipment, power, waste and engine management on ships and planes. The role SCADA plays in critical infrastructure has resulted in a call to secure them. Many lives depend on it for daily activities and the attack vectors are becoming more sophisticated. Hence, the security of ICS is vital as malfunction of it might result in huge risk. This paper describes how the application of Prey Predator (PP) approach in flocks of birds could enhance the detection of malicious activities on ICS. The PP approach explains how these animals in groups or flocks detect predators by following some simple rules. They are not necessarily very intelligent animals but their approach in solving complex issues such as detection through corporation, coordination and communication worth emulating. This paper will emulate flocking behavior seen in birds in detecting predators. The PP approach will adopt six nearest bird approach in detecting any predator. Their local and global bests are based on the individual detection as well as group detection. The PP algorithm was designed following MapReduce methodology that follows a Split Detection Convergence (SDC) approach.
Abstract: This article presents an interactive system for data acquisition in vehicle testing according to the test process defined in automotive directive 2004/104/EC. The project has been designed and developed by authors for the Spanish company Applus-LGAI. The developed project will result in a new process, which will involve the creation of braking cycle test defined in the aforementioned automotive directive. It will also allow the analysis of new vehicle features that was not feasible, allowing an increasing interaction with the vehicle. Potential users of this system in the short term will be vehicle manufacturers and in a medium term the system can be extended to testing other automotive components and EMC tests.
Abstract: With 40% of total world energy consumption,
building systems are developing into technically complex large
energy consumers suitable for application of sophisticated power
management approaches to largely increase the energy efficiency
and even make them active energy market participants. Centralized
control system of building heating and cooling managed by
economically-optimal model predictive control shows promising
results with estimated 30% of energy efficiency increase. The research
is focused on implementation of such a method on a case study
performed on two floors of our faculty building with corresponding
sensors wireless data acquisition, remote heating/cooling units and
central climate controller. Building walls are mathematically modeled
with corresponding material types, surface shapes and sizes. Models
are then exploited to predict thermal characteristics and changes in
different building zones. Exterior influences such as environmental
conditions and weather forecast, people behavior and comfort
demands are all taken into account for deriving price-optimal climate
control. Finally, a DC microgrid with photovoltaics, wind turbine,
supercapacitor, batteries and fuel cell stacks is added to make the
building a unit capable of active participation in a price-varying
energy market. Computational burden of applying model predictive
control on such a complex system is relaxed through a hierarchical
decomposition of the microgrid and climate control, where the
former is designed as higher hierarchical level with pre-calculated
price-optimal power flows control, and latter is designed as lower
level control responsible to ensure thermal comfort and exploit
the optimal supply conditions enabled by microgrid energy flows
management. Such an approach is expected to enable the inclusion
of more complex building subsystems into consideration in order to
further increase the energy efficiency.
Abstract: Current transformers are an integral part of power
system because it provides a proportional safe amount of current for
protection and measurement applications. However, when the power
system experiences an abnormal situation leading to huge current
flow, then this huge current is proportionally injected to the
protection and metering circuit. Since the protection and metering
equipment’s are designed to withstand only certain amount of current
with respect to time, these high currents pose a risk to man and
equipment. Therefore, during such instances, the CT saturation
characteristics have a huge influence on the safety of both man and
equipment and on the reliability of the protection and metering
system. This paper shows the effect of burden on the Accuracy Limiting
factor/ Instrument security factor of current transformers and the
change in saturation characteristics of the CT’s. The response of the
CT to varying levels of overcurrent at different connected burden will
be captured using the data acquisition software LabVIEW. Analysis
is done on the real time data gathered using LabVIEW. Variation of
current transformer saturation characteristics with changes in burden
will be discussed.
Abstract: There are a number of Distributed Generations (DGs)
installed in microgrid, which may have diverse path and direction of
power flow or fault current. The overcurrent protection scheme for the
traditional radial type distribution system will no longer meet the
needs of microgrid protection. Integrating the Intelligent Electronic
Device (IED) and a Supervisory Control and Data Acquisition
(SCADA) with IEC 61850 communication protocol, the paper
proposes a Microgrid Protection Management System (MPMS) to
protect power system from the fault. In the proposed method, the
MPMS performs logic programming of each IED to coordinate their
tripping sequence. The GOOSE message defined in IEC 61850 is used
as the transmission information medium among IEDs. Moreover, to
cope with the difference in fault current of microgrid between
grid-connected mode and islanded mode, the proposed MPMS applies
the group setting feature of IED to protect system and robust
adaptability. Once the microgrid topology varies, the MPMS will
recalculate the fault current and update the group setting of IED.
Provided there is a fault, IEDs will isolate the fault at once. Finally, the
Matlab/Simulink and Elipse Power Studio software are used to
simulate and demonstrate the feasibility of the proposed method.
Abstract: An experimental investigation is carried out to
establish the performance characteristics of a compression ignition
engine while using cerium oxide nanoparticles as additive in neat
diesel and diesel-biodiesel blends. In the first phase of the
experiments, stability of neat diesel and diesel-biodiesel fuel blends
with the addition of cerium oxide nanoparticles is analyzed. After
series of experiments, it is found that the blends subjected to high
speed blending followed by ultrasonic bath stabilization improves the
stability. In the second phase, performance characteristics are studied
using the stable fuel blends in a single cylinder four stroke engine
coupled with an electrical dynamometer and a data acquisition
system. The cerium oxide acts as an oxygen donating catalyst and
provides oxygen for combustion. The activation energy of cerium
oxide acts to burn off carbon deposits within the engine cylinder at
the wall temperature and prevents the deposition of non-polar
compounds on the cylinder wall results reduction in HC emissions.
The tests revealed that cerium oxide nanoparticles can be used as
additive in diesel and diesel-biodiesel blends to improve complete
combustion of the fuel significantly.
Abstract: Implementation of advanced technologies requires
sophisticated instruments that deal with the operation, control,
restoration and protection of rapidly growing power system network
under normal and abnormal conditions. Presently, the applications of
Phasor Measurement Unit (PMU) are widely found in real time
operation, monitoring, controlling and analysis of power system
network as it eliminates the various limitations of supervisory control
and data acquisition system (SCADA) conventionally used in power
system. The use of PMU data is very rapidly increasing its
importance for online and offline analysis. Wide area measurement
system (WAMS) is developed as new technology by use of multiple
PMUs in power system. The present paper proposes a model of
Matlab based PMU using Discrete Fourier Transform (DFT)
algorithm and evaluation of its operation under different
contingencies. In this paper, PMU based two bus system having
WAMS network is presented as a case study.
Abstract: The Figaro AM-1 sensor module which employs TGS
2600 model gas sensor in air quality assessment was used. The
system was coupled with a microprocessor that enables sensor
module to create warning message via telephone. This low cot sensor
system’s performance was compared with a DiagNose II commercial
electronic nose system. Both air quality sensor and electronic nose
system employ metal oxide chemical gas sensors. In the study
experimental setup, data acquisition methods for electronic nose
system, and performance of the low cost air quality system were
evaluated and explained.
Abstract: High density electrical prospecting has been widely
used in groundwater investigation, civil engineering and
environmental survey. For efficient inversion, the forward modeling
routine, sensitivity calculation, and inversion algorithm must be
efficient. This paper attempts to provide a brief summary of the past
and ongoing developments of the method. It includes reviews of the
procedures used for data acquisition, processing and inversion of
electrical resistivity data based on compilation of academic literature.
In recent times there had been a significant evolution in field survey
designs and data inversion techniques for the resistivity method. In
general 2-D inversion for resistivity data is carried out using the
linearized least-square method with the local optimization technique
.Multi-electrode and multi-channel systems have made it possible to
conduct large 2-D, 3-D and even 4-D surveys efficiently to resolve
complex geological structures that were not possible with traditional
1-D surveys. 3-D surveys play an increasingly important role in very
complex areas where 2-D models suffer from artifacts due to off-line
structures. Continued developments in computation technology, as
well as fast data inversion techniques and software, have made it
possible to use optimization techniques to obtain model parameters to
a higher accuracy. A brief discussion on the limitations of the
electrical resistivity method has also been presented.
Abstract: The detection of the polymer melt state during
manufacture process is regarded as an efficient way to control the
molded part quality in advance. Online monitoring rheological
property of polymer melt during processing procedure provides an
approach to understand the melt state immediately. Rheological
property reflects the polymer melt state at different processing
parameters and is very important in injection molding process
especially. An approach that demonstrates how to calculate
rheological property of polymer melt through in-process
measurement, using injection molding as an example, is proposed in
this study. The system consists of two sensors and a data acquisition
module can process the measured data, which are used for the
calculation of rheological properties of polymer melt. The rheological
properties of polymer melt discussed in this study include shear rate
and viscosity which are investigated with respect to injection speed
and melt temperature. The results show that the effect of injection
speed on the rheological properties is apparent, especially for high
melt temperature and should be considered for precision molding
process.
Abstract: Non-linear FEM calculations are indispensable when
important technical information like operating performance of a
rubber component is desired. For example rubber bumpers built into
air-spring structures may undergo large deformations under load,
which in itself shows non-linear behavior. The changing contact
range between the parts and the incompressibility of the rubber
increases this non-linear behavior further. The material
characterization of an elastomeric component is also a demanding
engineering task.
The shape optimization problem of rubber parts led to the study of
FEM based calculation processes. This type of problems was posed
and investigated by several authors. In this paper the time demand of
certain calculation methods are studied and the possibilities of time
reduction is presented.
Abstract: In order to better understand the long term
implications of the grout wear failure mode in large-diameter plainsided
grouted connections, a numerical model has been developed
and calibrated that can take advantage of existing operational plant
data to predict the wear accumulation for the actual load conditions
experienced over a given period, thus limiting the requirement for
expensive monitoring systems. This model has been derived and
calibrated based on site structural condition monitoring (SCM) data
and supervisory control and data acquisition systems (SCADA) data
for two operational wind turbine generator substructures afflicted
with this challenge, along with experimentally derived wear rates.
Abstract: The operation of nuclear power plants involves
continuous monitoring of the environment in their area. This
monitoring is performed using a complex data acquisition system,
which collects status information about the system itself and values
of many important physical variables e.g. temperature, humidity,
dose rate etc. This paper describes a proposal and optimization of
communication that takes place in teledosimetric system between the
central control server responsible for the data processing and storing
and the decentralized measuring stations, which are measuring the
physical variables. Analyzes of ongoing communication were
performed and consequently the optimization of the system
architecture and communication was done.
Abstract: Current transformers (CTs) are used to transform large primary currents to a small secondary current. Since most standard equipment’s are not designed to handle large primary currents the CTs have an important part in any electrical system for the purpose of Metering and Protection both of which are integral in Power system. Now a days due to advancement in solid state technology, the operation times of the protective relays have come to a few cycles from few seconds. Thus, in such a scenario it becomes important to study the transient response of the current transformers as it will play a vital role in the operating of the protective devices.
This paper shows the steady state and transient behavior of current transformers and how it changes with change in connected burden. The transient and steady state response will be captured using the data acquisition software LabVIEW. Analysis is done on the real time data gathered using LabVIEW. Variation of current transformer characteristics with changes in burden will be discussed.
Abstract: High resolution seismic reflection has recently been carried out on Zaria batholith, with the aim of characterizing the granitic Zaria batholiths in terms of its lithology. The geology of the area has revealed that the older granite outcrops in the vicinity of Zaria are exposures of a syntectonics to late-tectonic granite batholiths which intruded a crystalline gneissic basement during the Pan-African Orogeny. During the data acquisition the geophone were placed at interval of 1 m, variable offset of 1 and 10 m was used. The common midpoint (CMP) method with 12 fold coverage was employed for the survey. Analysis of the generated 3D surface of the p wave velocities from different profiles for densities and bulk modulus revealed that the rock material is more consolidated in South East part of the batholith and less consolidated in the North Western part. This was in conformity with earlier identified geology of the area, with the South Eastern part majorly of granitic outcrop, while the North Western part is characterized with the exposure of gneisses and thick overburden cover. The difference in lithology was also confirmed by the difference in seismic sections and Arial satellite photograph. Hence two major lithologies were identified, the granitic and gneisses complex which are characterized by gradational boundaries.
Abstract: Tsunami early detection and warning systems have proved to be of ultimate importance, especially after the destructive tsunami that hit Japan in March 2012. Such systems are crucial to inform the authorities of any risk of a tsunami and of the degree of its danger in order to make the right decision and notify the public of the actions they need to take to save their lives. The purpose of this research is to enhance existing tsunami detection and warning systems. We first propose an automated and miniaturized model of an early tsunami detection and warning system. The model for the operation of a tsunami warning system is simulated using the data acquisition toolbox of Matlab and measurements acquired from specified internet pages due to the lack of the required real-life sensors, both seismic and hydrologic, and building a graphical user interface for the system. In the second phase of this work, we implement various satellite image filtering schemes to enhance the acquired synthetic aperture radar images of the tsunami affected region that are masked by speckle noise. This enables us to conduct a post-tsunami damage extent study and calculate the percentage damage. We conclude by proposing improvements to the existing telecommunication infrastructure of existing warning tsunami systems using a migration to IP-based networks and fiber optics links.
Abstract: Time base maintenance (TBM) is conventionally applied by the power utilities to maintain circuit breakers (CBs), transformers, bus bars and cables, which may result in under maintenance or over maintenance. As information and communication technology (ICT) industry develops, the maintenance policies of many power utilities have gradually changed from TBM to condition base maintenance (CBM) to improve system operating efficiency, operation cost and power supply reliability. This paper discusses the feasibility of using intelligent electronic devices (IEDs) to construct a CB CBM management platform. CBs in power substations can be monitored using IEDs with additional logic configuration and wire connections. The CB monitoring data can be sent through intranet to a control center and be analyzed and integrated by the Elipse Power Studio software. Finally, a human-machine interface (HMI) of supervisory control and data acquisition (SCADA) system can be designed to construct a CBM management platform to provide maintenance decision information for the maintenance personnel, management personnel and CB manufacturers.
Abstract: This paper presents MOSFET based analog to digital converter which is simple in design, has high resolution, and conversion rate better than dual slope ADC. It has no DAC which will limit the performance, no error in conversion, can operate for wide range of inputs and never become unstable. One of the industrial applications, where the proposed high resolution MOSFET ADC can be used is, for the positioning of control valves in a multi channel data acquisition and control system (DACS), using stepper motors as actuators of control valves. It is observed that in a DACS having ten control valves, 0.02% of positional accuracy of control valves can be achieved with the data update period of 250ms and with stepper motors of maximum pulse rate 20 Kpulses per sec. and minimum pulse width of 2.5 μsec. The reported accuracy so far by other authors is 0.2%, with update period of 255 ms and with 8 bit DAC. The accuracy in the proposed configuration is limited by the available precision stepper motor and not by the MOSFET based ADC.
Abstract: This paper describes a software approach for modeling inverter fed induction motor drive using Laboratory Virtual Instrument Engineering Workbench (LabVIEW). The reason behind the selection of LabVIEW software is because of its strong graphical interface, flexibility of its programming language combined with built-in tools designed specifically for test, measurement and control. LabVIEW is generally used in most of the applications for data acquisition, test and control. In this paper, inverter and induction motor are modeled using LabVIEW toolkits. Simulation results are presented and are validated.
Abstract: To support design process for launching the product on time, reverse engineering (RE) process has been introduced for quickly generating 3D CAD model from its physical object. The accuracy of the 3D CAD model depends upon the data acquisition technique selected, contact or non-contact methods. In order to reduce times used for acquiring surface and eliminating noises, the automated selective acquisition system has been developed and presented in this research as the alternative channel for non-contact acquisition technique where the data is selectively and locally scanned contour by contour without performing data reduction process. The results present as the organized contour points which are directly used to generate 3D virtual model. The comparison between the proposed technique and another non-contact scanning technique has been presented and discussed.