Abstract: Current transformers are an integral part of power
system because it provides a proportional safe amount of current for
protection and measurement applications. However, when the power
system experiences an abnormal situation leading to huge current
flow, then this huge current is proportionally injected to the
protection and metering circuit. Since the protection and metering
equipment’s are designed to withstand only certain amount of current
with respect to time, these high currents pose a risk to man and
equipment. Therefore, during such instances, the CT saturation
characteristics have a huge influence on the safety of both man and
equipment and on the reliability of the protection and metering
system. This paper shows the effect of burden on the Accuracy Limiting
factor/ Instrument security factor of current transformers and the
change in saturation characteristics of the CT’s. The response of the
CT to varying levels of overcurrent at different connected burden will
be captured using the data acquisition software LabVIEW. Analysis
is done on the real time data gathered using LabVIEW. Variation of
current transformer saturation characteristics with changes in burden
will be discussed.
Abstract: Un-doped GaN film of thickness 1.90 mm, grown on
sapphire substrate were uniformly implanted with 325 keV Mn+ ions
for various fluences varying from 1.75 x 1015 - 2.0 x 1016 ions cm-2 at
3500 C substrate temperature. The structural, morphological and
magnetic properties of Mn ion implanted gallium nitride samples
were studied using XRD, AFM and SQUID techniques. XRD of the
sample implanted with various ion fluences showed the presence of
different magnetic phases of Ga3Mn, Ga0.6Mn0.4 and Mn4N.
However, the compositions of these phases were found to be
depended on the ion fluence. AFM images of non-implanted sample
showed micrograph with rms surface roughness 2.17 nm. Whereas
samples implanted with the various fluences showed the presence of
nano clusters on the surface of GaN. The shape, size and density of
the clusters were found to vary with respect to ion fluence. Magnetic
moment versus applied field curves of the samples implanted with
various fluences exhibit the hysteresis loops. The Curie temperature
estimated from zero field cooled and field cooled curves for the
samples implanted with the fluence of 1.75 x 1015, 1.5 x 1016 and 2.0
x 1016 ions cm-2 was found to be 309 K, 342 K and 350 K
respectively.