Abstract: This study was carried out for an underground subway station at Seoul Metro, Korea. The optimal set-points of the ventilation control system are determined every 3 hours, then, the ventilation controller adjusts the ventilation fan speed according to the optimal set-point changes. Compared to manual ventilation system which is operated irrespective of the OAQ, the IDP-based ventilation control system saves 3.7% of the energy consumption. Compared to the fixed set-point controller which is operated irrespective of the IAQ diurnal variation, the IDP-based controller shows better performance with a 2% decrease in energy consumption, maintaining the comfortable IAQ range inside the station.
Abstract: This paper presents the results obtained by numerical
simulation using the software ANSYS CFX-CFD for the air
pollutants dispersion in the atmosphere coming from the evacuation
of combustion gases resulting from the fuel combustion in an electric
thermal power plant. The model uses the Navier-Stokes equation to
simulate the dispersion of pollutants in the atmosphere. It is
considered as important factors in elaboration of simulation the
atmospheric conditions (pressure, temperature, wind speed, wind
direction), the exhaust velocity of the combustion gases, chimney
height and the obstacles (buildings). Using the air quality monitoring
stations it is measured the concentrations of main pollutants (SO2,
NOx and PM). The pollutants were monitored over a period of 3
months, after that the average concentration are calculated, which is
used by the software. The concentrations are: 8.915 μg/m3 (NOx),
9.587 μg/m3 (SO2) and 42 μg/m3 (PM). A comparison of test data
with simulation results demonstrated that CFX was able to describe
the dispersion of the pollutant as well the concentration of this
pollutants in the atmosphere.
Abstract: In this paper air quality conditions in Makkah and
Leeds are compared. These two cities have totally different climatic
conditions. Makkah climate is characterised as hot and dry (arid)
whereas that of Leeds is characterised as cold and wet (temperate).
This study uses air quality data from 2012 collected in Makkah,
Saudi Arabia and Leeds, UK. The concentrations of all pollutants,
except NO are higher in Makkah. Most notable, the concentrations of
PM10 are much higher in Makkah than in Leeds. This is probably due
to the arid nature of climatic conditions in Makkah and not solely due
to anthropogenic emission sources, otherwise like PM10 some of the
other pollutants, such as CO, NO, and SO2 would have shown much
greater difference between Leeds and Makkah. Correlation analysis is
performed between different pollutants at the same site and the same
pollutants at different sites. In Leeds the correlation between PM10
and other pollutants is significantly stronger than in Makkah. Weaker
correlation in Makkah is probably due to the fact that in Makkah
most of the gaseous pollutants are emitted by combustion processes,
whereas most of the PM10 is generated by other sources, such as
windblown dust, re-suspension, and construction activities. This is in
contrast to Leeds where all pollutants including PM10 are
predominantly emitted by combustions, such as road traffic.
Furthermore, in Leeds frequent rains wash out most of the
atmospheric particulate matter and suppress re-suspension of dust.
Temporal trends of various pollutants are compared and discussed.
This study emphasises the role of climatic conditions in managing air
quality, and hence the need for region-specific controlling strategies
according to the local climatic and meteorological conditions.
Abstract: The main objective of this study was to assess the
seasonal variation of atmospheric polycyclic aromatic hydrocarbon
(PAH) concentrations associated with PM10 in an urban site of Győr,
Hungary. A total of 112 PM10 aerosol samples were collected in the
years of 2012 and 2013 and analyzed for PAHs by gas
chromatography method. The total PAH concentrations (sum of the
concentrations of 19 individual PAH compounds) ranged from 0.19
to 70.16 ng/m3 with the mean value of 12.29 ng/m3. Higher
concentrations of both total PAHs and benzo[a]pyrene (BaP) were
detected in samples collected in the heating seasons. Using BaPequivalent
potency index on the carcinogenic PAH concentration
data, the local population appears to be exposed to significantly
higher cancer risk in the heating seasons. However, the comparison
of the BaP and total PAH concentrations observed for Győr with
other cities it was found that the PAH levels in Győr generally
corresponded to the EU average.
Abstract: The Figaro AM-1 sensor module which employs TGS
2600 model gas sensor in air quality assessment was used. The
system was coupled with a microprocessor that enables sensor
module to create warning message via telephone. This low cot sensor
system’s performance was compared with a DiagNose II commercial
electronic nose system. Both air quality sensor and electronic nose
system employ metal oxide chemical gas sensors. In the study
experimental setup, data acquisition methods for electronic nose
system, and performance of the low cost air quality system were
evaluated and explained.
Abstract: The main objective of this study was to assess the
annual concentration and seasonal variation of benzo(a)pyrene (BaP)
associated with PM10 in an urban site of Győr and in a rural site of
Sarród in the sampling period of 2008–2012. A total of 280 PM10
aerosol samples were collected in each sampling site and analyzed for
BaP by gas chromatography method. The BaP concentrations ranged
from undetected to 8 ng/m3 with the mean value of 1.01 ng/m3 in the
sampling site of Győr, and from undetected to 4.07 ng/m3 with the
mean value of 0.52 ng/m3 in the sampling site of Sarród, respectively.
Relatively higher concentrations of BaP were detected in samples
collected in both sampling sites in the heating seasons compared with
non-heating periods. The annual mean BaP concentrations were
comparable with the published data of different other Hungarian
sites.
Abstract: Based on an indoor environmental quality (IEQ) index established by previous work that indicates the overall IEQ acceptance from the prospect of an occupant in residential buildings in terms of four IEQ factors - thermal comfort, indoor air quality, visual and aural comforts, this study develops a user-friendly IEQ calculator for iOS and Android users to calculate the occupant acceptance and compare the relative performance of IEQ in apartments. “IEQ calculator” is easy to use and it preliminarily illustrates the overall indoor environmental quality on the spot. Users simply input indoor parameters such as temperature, number of people and windows are opened or closed for the mobile application to calculate the scores in four areas: the comforts of temperature, brightness, noise and indoor air quality. The calculator allows the prediction of the best IEQ scenario on a quantitative scale. Any indoor environments under the specific IEQ conditions can be benchmarked against the predicted IEQ acceptance range. This calculator can also suggest how to achieve the best IEQ acceptance among a group of residents.
Abstract: Prosperity of electronic equipment in photocopying
environment not only has improved work efficiency, but also has
changed indoor air quality. Considering the number of photocopying
employed, indoor air quality might be worse than in general office
environments. Determining the contribution from any type of
equipment to indoor air pollution is a complex matter. Non-methane
hydrocarbons are known to have an important role on air quality due
to their high reactivity. The presence of hazardous pollutants in
indoor air has been detected in one photocopying shop in Novi Sad,
Serbia. Air samples were collected and analyzed for five days, during
8-hr working time in three time intervals, whereas three different
sampling points were determined. Using multiple linear regression
model and software package STATISTICA 10 the concentrations of
occupational hazards and microclimates parameters were mutually
correlated. Based on the obtained multiple coefficients of
determination (0.3751, 0.2389 and 0.1975), a weak positive
correlation between the observed variables was determined. Small
values of parameter F indicated that there was no statistically
significant difference between the concentration levels of nonmethane
hydrocarbons and microclimates parameters. The results
showed that variable could be presented by the general regression
model: y = b0 + b1xi1+ b2xi2. Obtained regression equations allow to
measure the quantitative agreement between the variables and thus
obtain more accurate knowledge of their mutual relations.
Abstract: Emissions of atmospheric pollutants from ships and
harbour activities are a growing concern at international level given
their potential impacts on air quality and climate. These close-to-land
emissions have potential impact on local communities in terms of air
quality and health. Recent studies show that the impact of maritime
traffic to atmospheric particulate matter concentrations in several
coastal urban areas is comparable with the impact of road traffic of a
medium size town. However, several different approaches have been
used for these estimates making difficult a direct comparison of
results. In this work, an integrated approach based on emission
inventories and dedicated measurement campaigns has been applied
to give a comparable estimate of the impact of maritime traffic to
PM2.5 and particle number concentrations in three major harbours of
the Adriatic/Ionian Seas. The influences of local meteorology and of
the logistic layout of the harbours are discussed.
Abstract: Although there had been a many studies that shows
the impact of air pollution on physical health, comparatively less was
known of human behavioral responses and annoyance impacts.
Annoyance caused by air pollution is a public health problem because
it can be an ambient stressor causing stress and disease and can affect
quality of life. The objective of this work is to evaluate the
annoyance caused by air pollution in two different industrialized
urban areas, Dunkirk (France) and Vitoria (Brazil). The populations
of these cities often report feeling annoyed by dust. Surveys were
conducted, and the collected data were analyzed using statistical
analyses. The results show that sociodemographic variables,
importance of air quality, perceived industrial risk, perceived air
pollution and occurrence of health problems play important roles in
the perceived annoyance. These results show the existence of a
common problem in geographically distant areas and allow
stakeholders to develop prevention strategies.
Abstract: The aim of this paper is to give an assessment of
environmental effects of IPPC permit conditions of installations that
are in specific territory with high concentration of industrial
activities.
The IPPC permit is the permit that each operator should hold to
operate the installation as stated by the directive 2010/75/UE on
industrial emissions (integrated pollution prevention and control),
known as IED (Industrial Emissions Directive).
The IPPC permit includes all the measures necessary to achieve a
high level of protection of the environment as a whole, also defining
the monitoring requirements as measurement methodology,
frequency and evaluation procedure. The emissions monitoring of a
specific plant may also give indications of the contribution of these
emissions on the air quality of a definite area.
So, it is clear that the IPPC permits are important tools both to
improve the environmental framework and to achieve the air quality
standards, assisting to assess the possible industrial sources
contributions to air pollution.
Abstract: Member States shall establish zones and
agglomerations throughout their territory to assess and manage air
quality in order to comply with European directives.
In Italy decree 155/2010, transposing Directive 2008/50/EC on
ambient air quality and cleaner air for Europe, merged into a single
act the previous provisions on ambient air quality assessment and
management, including those resulting from the implementation of
Directive 2004/107/EC relating to arsenic, cadmium, nickel, mercury
and polycyclic aromatic hydrocarbons in ambient air.
Decree 155/2010 introduced stricter rules for identifying zones on
the basis of the characteristics of the territory in spite of considering
pollution levels, as it was in the past. The implementation of such
new criteria has reduced the great variability of the previous zoning,
leading to a significant reduction of the total number of zones and to
a complete and uniform ambient air quality assessment and
management throughout the Country.
The present document is related to the new zones definition in
Italy according to Decree 155/2010. In particular the paper contains
the description and the analysis of the outcome of zoning and
classification.
Abstract: Fugitive particulate matter (PM) is a major source of
airborne pollution in the Middle East countries. The meteorological
conditions and topography of the area makes it highly susceptible to
wind-blown particles which raise many air quality concerns. Air
quality tools such as field monitoring, emission factors and dispersion
modeling have been used in previous research studies to analyze the
release and impacts of fugitive PM in the region. However, these
tools have been originally developed based on experiments made for
European and North American regions. In this work, an experimental
campaign was conducted on April-May 2014 in a construction site in
Doha city, Qatar. The ultimate goal is to evaluate the applicability of
the existing emission factors for construction sites in dry and arid
areas like the Middle East.
Abstract: Sustainable tall buildings that provide comfortable,
healthy and efficient indoor environments are clearly desirable as the
densification of living and working space for the world’s increasing
population proceeds. For environmental concerns, these buildings
must also be energy efficient. One component of these tasks is the
provision of indoor air quality and thermal comfort, which can be
enhanced with natural ventilation by the supply of fresh air. Working
spaces can only be naturally ventilated with connections to the
outdoors utilizing operable windows, double facades, ventilation
stacks, balconies, patios, terraces and skygardens. Large amounts of
fresh air can be provided to the indoor spaces without mechanical
air-conditioning systems, which are widely employed in
contemporary tall buildings.
This paper tends to present the concept of natural ventilation for
sustainable tall office buildings in order to achieve healthy and
comfortable working spaces, as well as energy efficient
environments. Initially the historical evolution of ventilation
strategies for tall buildings is presented, beginning with natural
ventilation and continuing with the introduction of mechanical airconditioning
systems. Then the emergence of natural ventilation due
to the health and environmental concerns in tall buildings is handled,
and the strategies for implementing this strategy are revealed. In the
next section, a number of case studies that utilize this strategy are
investigated. Finally, how tall office buildings can benefit from this
strategy is discussed.
Abstract: This research aims to study the Zinc (Zn) concentration in fine particulate matter on Rajchawithee roadside in rush hour. 30 Samples were collected in Jun to August 2013 by 8 stage non-avaible cascade impactor. Each samples (filter paper) were digest with nitric acid and analyed by atomic absorption spectrophotometer for Zinc determination. The highest value for the mean fraction (18.00 ± 9.28%) is the size 9.0 – 110.0 micron follow by the range 3.3 – 4.7 micron (14.77 ± 14.66 %) and 1.1 – 2.1 micron (14.01 ± 11.77 %). The concentration of Zn in the particulate matter of range 0.43 – 0.7mm, 0.7 – 1.1 mm, 1.1 – 2.1 mm, 2.1 – 3.3 mm, 3.3 – 4.7 mm, 4.7 – 5.8 mm, 5.8 – 9.0 mm, 9.0 – 10.0 mm, were 41.56 – 217.62 mg/m3 (175.86 ±32.25 mg/m3), 152.60 – 217.24 mg/m3 (187.71 ± 17.42 mg/m3), 142.90 – 214.67 mg/m3(180.95 ± 18.71 mg/m3), 155.48 – 218.19 mg/m3(183.22 ± 19.94 mg/m3), 151.72 – 217.39 mg/m3(181.85 ± 17.57 mg/m3), 133.86 – 220.17 mg/m3 (178.78 ± 23.45 mg/m3), 160.00 – 220.35 mg/m3 (182.58 ± 18.08 mg/m3), 153.30 – 226.70 mg/m3 (181.52 ± 20.05 mg/m3), respectively. The Zn concentration in each size of particulate matter was not statistically significant different (p > .005)
Abstract: Nowadays harmonization of sanitary and hygienic standards of environmental quality with international standards is crucial part of integration of Russia into the international community. Harmonization of Russian and international ambient air quality standards may be realized by risk-based standards development. In this paper approaches to risk-based standards development and examples of these approaches implementation are presented.
Abstract: Displacement ventilation of a room with an occupant is modeled using CFD. The geometry of manikin is accurately represented in CFD model to minimize potential. Indoor zero equation turbulence model is used to simulate all cases and the effect of the thermal radiation from manikin is taken into account. After validation of the code, predicted mean vote, mean age of air, and ventilation effectiveness are used to predict the thermal comfort zones and indoor air quality. The effect of the inlet velocity and temperature on the thermal comfort and indoor air quality is investigated. The results show that the inlet velocity has great effect on the thermal comfort and indoor air quality and low inlet velocity is sufficient to establish comfortable conditions inside the room. In addition, the displacement ventilation system achieves not only thermal comfort in ventilated rooms, but also energy saving of fan power.
Abstract: The main objective of this study was to investigate particulate matter concentration on main and secondary roadsides in urban area and study the concentration of some heavy metals including lead (Pb), zinc (Zn), copper (Cu) and cadmium (Cd) in particulate matter in the Bangkok area.
The averaged particle concentration for main roadsides is higher than secondary roadsides. The particulate matter less than 10 micron concentration contribute the majority of the Total Suspended Particulate matter for main roads and zinc concentrations were higher than copper and lead for both sites.
Abstract: Understanding the behavior of airflow in a room is essential for building designers to provide the most efficient design of ventilation system, and having acceptable indoor air quality. This trend is the motive to solve the relationship between airflow parameters and thermal comfort. This paper investigates airflow characteristics, indoor air quality (IAQ), and the thermal comfort (TC) in a ventilated room with a displacement ventilation system using three dimensional CFD code [AirPak 2.0.6]. After validation of the code, a numerical study is executed for a typical room with dimensions of 5m by 3m by 3m height according to a variety of supply air velocities, supply air temperature and supply air relative humidity. The finite volume method and the indoor zero equation turbulence models are employed for solving the governing equations numerically. The temperature field and the mean age of air (MAA) in the modeled room for a displacement ventilation system are determined according to a variety of the above parameters. The variable air volume (VAV) systems with different supply air velocity are applicable to control room air temperature for a displacement ventilation system.
Abstract: Monitoring is essential to assessing the effectiveness of air pollution control actions. The goal of the air quality information system is through monitoring, to keep authorities, major polluters and the public informed on the short and long-term changes in air quality, thereby helping to raise awareness. Mathematical models are the best tools available for the prediction of the air quality management. The main objective of the work was to apply a Model that predicts the concentration levels of different pollutants at any instant of time. In this study, distribution of air pollutants concentration such as nitrogen dioxides (NO2), sulphur dioxides (SO2) and total suspended particulates (TSP) of industries are determined by using Gaussian model. Besides that, the effect of wind speed and its direction on the pollutant concentration within the affected area were evaluated. In order to determine the efficiency and percentage of error in the modeling, validation process of data was done. Sampling of air quality was conducted in getting existing air quality around a factory and the concentrations of pollutants in a plume were inversely proportional to wind velocity. The resultant ground level concentrations were then compared to the quality standards to determine if there could be a negative impact on health. This study concludes that concentration of pollutants can be significantly predicted using Gaussian Model. The data base management is developed for the air data of Hubli-Dharwad region.