Abstract: Human mobility exoskeletons have been in development for several years and are becoming increasingly efficient. Unfortunately, user comfort was not always a priority design criterion throughout their development. To further improve this technology, exoskeletons should operate and deliver assistance without causing discomfort to the user. For this, improvements are necessary from an ergonomic point of view. The device’s control method is important when endeavoring to enhance user comfort. Exoskeleton or rehabilitation device controllers use methods of control called interaction controls (admittance and impedance controls). This paper proposes an extended version of an admittance controller to enhance user comfort. The control method used consists of adding an inner loop that is controlled by a proportional-integral-derivative (PID) controller. This allows the interaction force to be kept as close as possible to the desired force trajectory. The force-tracking admittance controller modifies the actuation force of the system in order to follow both the desired motion trajectory and the desired relative force between the user and the exoskeleton.
Abstract: This paper presents design and analysis of an electrothermally symmetrical actuated microgripper applicable for performing micro assembly or biological cell manipulation. Integration of micro-optics with microdevice leads to achieve extremely precise control over the operation of the device. Geometry, material, actuation, control, accuracy in measurement and temperature distribution are important factors which have to be taken into account for designing the efficient microgripper device. In this work, analyses of four different geometries are performed by means of COMSOL Multiphysics 5.2 with implementing Finite Element Methods. Then, temperature distribution along the fingertip, displacement of gripper site as well as optical efficiency vs. displacement and electrical potential are illustrated. Results show in addition to the industrial application of this device, the usage of that as a cell manipulator is possible.
Abstract: Characterizing the fatigue and fracture properties of nanostructures is one of the most challenging tasks in nanoscience and nanotechnology due to lack of a MEMS/NEMS device for generating uniform cyclic loadings at high frequencies. Here, the dynamic response of a recently proposed MEMS/NEMS device under different inputs signals is completely investigated. This MEMS/NEMS device is designed and modeled based on the electromagnetic force induced between paired parallel wires carrying electrical currents, known as Ampere’s Force Law (AFL). Since this MEMS/NEMS device only uses two paired wires for actuation part and sensing part, it represents highly sensitive and linear response for nanostructures with any stiffness and shapes (single or arrays of nanowires, nanotubes, nanosheets or nanowalls). In addition to studying the maximum gains at different resonance frequencies of the MEMS/NEMS device, its dynamical responses are investigated for different inputs and nanostructure properties to demonstrate the capability, usability, and reliability of the device for wide range of nanostructures. This MEMS/NEMS device can be readily integrated into SEM/TEM instruments to provide real time study of the fatigue and fracture properties of nanostructures as well as their softening or hardening behaviors, and initiation and/or propagation of nanocracks in them.
Abstract: This paper presents a MEMS/NEMS device for fatigue and fracture characterization of nanomaterials. This device can apply static loads, cyclic loads, and their combinations in nanomechanical experiments. It is based on the electromagnetic force induced between paired parallel wires carrying electrical currents. Using this concept, the actuator and sensor parts of the device were designed and analyzed while considering the practical limitations. Since the PWCC device only uses two wires for actuation part and sensing part, its fabrication process is extremely easier than the available MEMS/NEMS devices. The total gain and phase shift of the MEMS/NEMS device were calculated and investigated. Furthermore, the maximum gain and sensitivity of the MEMS/NEMS device were studied to demonstrate the capability and usability of the device for wide range of nanomaterials samples. This device can be readily integrated into SEM/TEM instruments to provide real time study of the mechanical behaviors of nanomaterials as well as their fatigue and fracture properties, softening or hardening behaviors, and initiation and propagation of nanocracks.
Abstract: The utilization of pneumatic muscles in the actuation of industrial systems is still in its early stages, hence studies on the constructive solutions which include an assessment of their functional performance with a focus on one of the most important characteristics-energy efficiency are required. A quality indicator that adequately reflects the energy efficiency of an actuator is the energy-to-mass ratio. This ratio is computed in the paper for various types and sizes of pneumatic muscles manufactured by Festo, and is subsequently compared to the similar ratios determined for two categories of pneumatic cylinders.
Abstract: This paper presents the effect of actuation schemes on the performance of parallel manipulators and also how the singularity loci have been changed in the reachable workspace of the manipulator with the choice of actuation scheme to drive the manipulator. The performance of the eight possible actuation schemes of 3RRR planar parallel manipulator is compared with each other. The optimal design problem is formulated to find the manipulator geometry that maximizes the singularity free conditioned workspace for all the eight actuation cases, the optimization problem is solved by using genetic algorithms.
Abstract: This paper addresses the control problem of a class of hyper-redundant arms. In order to avoid discrepancy between the mathematical model and the actual dynamics, the dynamic model with uncertain parameters of this class of manipulators is inferred. A procedure to design a feedback controller which stabilizes the uncertain system has been proposed. A PD boundary control algorithm is used in order to control the desired position of the manipulator. This controller is easy to implement from the point of view of measuring techniques and actuation. Numerical simulations verify the effectiveness of the presented methods. In order to verify the suitability of the control algorithm, a platform with a 3D flexible manipulator has been employed for testing. Experimental tests on this platform illustrate the applications of the techniques developed in the paper.
Abstract: The objective of this work is to carryout critical
comparison of different actuation mechanisms like electrostatic,
thermal, piezoelectric, and magnetic with reference to a micro
cantilever. The relevant parameters like force generated,
displacement are compared in actuation methods. With these results,
helps in choosing the best actuation method for a particular
application. In this study, Comsol/Multiphysics software is used.
Modeling and simulation is done by considering the micro cantilever
of same dimensions as an actuator using all the above mentioned
actuation techniques. In addition to their small size, micro actuators
consume very little power and are capable of accurate results. In this
work, a comparison of actuation mechanisms is done to decide the
efficient system in micro domain.
Abstract: We propose new multiple-channel piezoelectric (PZT)
actuated tunable optical filter based on racetrack multi-ring
resonators for wavelength de-multiplexing network applications. We
design tunable eight-channel wavelength de-multiplexer consisting of
eight cascaded PZT actuated tunable multi-ring resonator filter with a
channel spacing of 1.6nm. The filter for each channel is basically
structured on a suspended beam, sandwiched with piezoelectric
material and built in integrated ring resonators which are placed on
the middle of the beam to gain uniform stress and linearly varying
longitudinal strain. A reference single mode serially coupled multi
stage racetrack ring resonator with the same radii and coupling length
is designed with a line width of 0.8974nm with a flat top pass band at
1dB of 0.5205nm and free spectral range of about 14.9nm. In each
channel, a small change in the perimeter of the rings is introduced to
establish the shift in resonance wavelength as per the defined channel
spacing. As a result, when a DC voltage is applied, the beams will
elongate, which involves mechanical deformation of the ring
resonators that induces a stress and a strain, which brings a change in
refractive index and perimeter of the rings leading to change in the
output spectrum shift providing the tunability of central wavelength
in each channel. Simultaneous wave length shift as high as
45.54pm/
Abstract: The efficiency of the actuation system of exoskeletons
and active orthoses for lower limbs is a significant aspect of the
design of such devices because it affects their efficacy. The F-IVT is
an innovative actuation system to power artificial knee joint with
energy recovery capabilities. Its key and non-conventional elements
are a flywheel that acts as a mechanical energy storage system, and
an Infinitely Variable Transmission (IVT). The design of the F-IVT
can be optimized for a certain walking condition, resulting in a heavy
reduction of both the electric energy consumption and of the electric
peak power. In this work, by means of simulations of level ground
walking at different speeds, it is demonstrated that the F-IVT is still
an advantageous actuator which permits to save energy consumption
and to downsize the electric motor even when it does not work in
nominal conditions.
Abstract: This paper presents development of the light-weight manipulator with series elastic actuation for medical telediagnostics (USG examination). General structure of realized impedance control algorithm was shown. It was described how to perform force measurements based mainly on elasticity of manipulator links.
Abstract: An optimisation method using both global and local
optimisation is implemented to determine the flapping profile which
will produce the most lift for an experimental wing-actuation system.
The optimisation method is tested using a numerical quasi-steady
analysis. Results of an optimised flapping profile show a 20% increase
in lift generated as compared to flapping profiles obtained by high
speed cinematography of a Sympetrum frequens dragonfly. Initial
optimisation procedures showed 3166 objective function evaluations.
The global optimisation parameters - initial sample size and stage
one sample size, were altered to reduce the number of function
evaluations. Altering the stage one sample size had no significant
effect. It was found that reducing the initial sample size to 400
would allow a reduction in computational effort to approximately
1500 function evaluations without compromising the global solvers
ability to locate potential minima. To further reduce the optimisation
effort required, we increase the local solver’s convergence tolerance
criterion. An increase in the tolerance from 0.02N to 0.05N decreased
the number of function evaluations by another 20%. However, this
potentially reduces the maximum obtainable lift by up to 0.025N.
Abstract: A mechanically-resonant torsional spring scanner was developed in a recent study. Various methods were developed to improve the angular displacement of the scanner while maintaining the scanner frequency. However the effects of rotor magnet radial position on scanner characteristics were not well investigated. In this study, the relationships between the magnet position and the scanner characteristics such as natural frequency, angular displacement and stress level were studied. A finite element model was created and an average deviation of 3.18% was found between the simulation and experimental results, qualifying the simulation results as a guide for further investigations. Three magnet positions on the transverse oscillating suspended plate were investigated by finite element analysis (FEA) and one of the positions were selected as the design position. The magnet position with the longest distance from the twist axis of mirror was selected since it attains minimum stress level, while exceeding the minimum critical flicker frequency and delivering the targeted angular displacement to the scanner.
Abstract: The Ambidextrous Robot Hand is a robotic device with the purpose to mimic either the gestures of a right or a left hand. The symmetrical behavior of its fingers allows them to bend in one way or another keeping a compliant and anthropomorphic shape. However, in addition to gestures they can reproduce on both sides, an asymmetrical mechanical design with a three tendons routing has been engineered to reduce the number of actuators. As a consequence, control algorithms must be adapted to drive efficiently the ambidextrous fingers from one position to another and to include grasping features. These movements are controlled by pneumatic muscles, which are nonlinear actuators. As their elasticity constantly varies when they are under actuation, the length of pneumatic muscles and the force they provide may differ for a same value of pressurized air. The control algorithms introduced in this paper take both the fingers asymmetrical design and the pneumatic muscles nonlinearity into account to permit an accurate control of the Ambidextrous Robot Hand. The finger motion is achieved by combining a classic PID controller with a phase plane switching control that turns the gain constants into dynamic values. The grasping ability is made possible because of a sliding mode control that makes the fingers adapt to the shape of an object before strengthening their positions.
Abstract: We present in this work the performances of a mobile omnidirectional robot through evaluating its management of the redundancy of actuation. Thus we come to the predictive control implemented.
The distribution of the wringer on the robot actions, through the inverse pseudo of Moore-Penrose, corresponds to a « geometric ›› distribution of efforts. We will show that the load on vehicle wheels would not be equi-distributed in terms of wheels configuration and of robot movement.
Thus, the threshold of sliding is not the same for the three wheels of the vehicle. We suggest exploiting the redundancy of actuation to reduce the risk of wheels sliding and to ameliorate, thereby, its accuracy of displacement. This kind of approach was the subject of study for the legged robots.
Abstract: Continuously variable transmission (CVT) is a type of
automatic transmission that can change the gear ratio to any arbitrary
setting within the limits. The most common type of CVT operates on
a pulley system that allows an infinite variability between highest and
lowest gears with no discrete steps. However, the current CVT
system with hydraulic actuation method suffers from the power loss.
It needs continuous force for the pulley to clamp the belt and hold the
torque resulting in large amount of energy consumption. This study
focused on the development of an electromechanical actuated control
CVT to eliminate the problem that faced by the existing CVT. It is
conducted with several steps; computing and selecting the
appropriate sizing for stroke length, lead screw system and etc. From
the visual observation it was found that the CVT system of this
research is satisfactory.
Abstract: Due to environmental concerns, the recent regulation on automobile fuel economy has been strengthened. The market demand for efficient vehicles is growing and automakers to improve engine fuel efficiency in the industry have been paying a lot of effort. To improve the fuel efficiency, it is necessary to reduce losses or to improve combustion efficiency of the engine. VVA (Variable Valve Actuation) technology enhances the engine's intake air flow, reduce pumping losses and mechanical friction losses. And also, VVA technology is the engine's low speed and high speed operation to implement each of appropriate valve lift. It improves the performance of engine in the entire operating range. This paper presents a design procedure of DC motor and drive for VVA system and shows the validity of the design result by experimental result with prototype.
Abstract: This paper addresses the problem of asymptotic tracking
control of a linear parabolic partial differential equation with indomain
point actuation. As the considered model is a non-standard
partial differential equation, we firstly developed a map that allows
transforming this problem into a standard boundary control problem
to which existing infinite-dimensional system control methods can
be applied. Then, a combination of energy multiplier and differential
flatness methods is used to design an asymptotic tracking controller.
This control scheme consists of stabilizing state-feedback derived
from the energy multiplier method and feed-forward control based
on the flatness property of the system. This approach represents
a systematic procedure to design tracking control laws for a class
of partial differential equations with in-domain point actuation. The
applicability and system performance are assessed by simulation
studies.
Abstract: This paper presents a synthetic jet air blower actuated
by PZT for air blowing for air-breathing micro PEM fuel cell. The
several factors to affect the performance of air-breathing PEM fuel cell
such as air flow rate, opening ratio and cathode open type in the
cathode side were studied. Especially, an air flow rate is critical
condition to improve its performance. In this paper, we developed a
synthetic jet air blower to supply a high stoichiometric air flow. The
synthetic jet mechanism is a zero mass flux device that converts
electrical energy into the momentum. The synthetic jet actuation is
usually generated by a traditional PZT actuator, which consists of a
small cylindrical cavity, in/outlet channel and PZT diaphragms. The
flow rate of the fabricated synthetic jet air blower was 400cc/min at
550Hz and its power consumption was very low under 0.3W. The
proposed air-breathing PEM fuel cell which installed synthetic jet air
blower was higher performance and stability during continuous
operation than the air-breathing fuel cell without auxiliary device to
supply the air. The results showed that the maximum power density
was 188mW/cm2 at 400mA/cm2. This maximum power density and
durability were improved more than 40% and 20%, respectively.
Abstract: The problem of controlling a two link robotic manipulator, consisting of a rotating and a prismatic links, is addressed. The actuations of both links are assumed to have unknown dead zone nonlinearities and friction torques modeled by LuGre friction model. Because of the existence of the unknown dead zone and friction torque at the actuations, unknown parameters and unmeasured states would appear to be part of the overall system dynamics that need for estimation. Unmeasured states observer, unknown parameters estimators, and robust adaptive control laws have been derived such that closed loop global stability is achieved. Simulation results have been performed to show the efficacy of the suggested approach.