Abstract: One of the most challenging times in operation of big industrial plant or utilities is the time that alert lamp of Bently Nevada connection in main board substation turn on and show the alert condition of machine. All of the maintenance groups usually make a lot of discussion with operation and together rather this alert signal is real or fake. This will be more challenging when condition monitoring vibrationdata shows 1X(X=current rotor frequency) in fast Fourier transform(FFT) and vibration phase trends show 90 degree shift between two non-contact probedirections with overall high radial amplitude amounts. In such situations, CM (condition monitoring) groups usually suspicious about unbalance in rotor. In this paper, four critical case histories related to SIEMENS V94.2 Gas Turbines in Iran power industry discussed in details. Furthermore, probe looseness and fake (unreal) trip in gas turbine power plants discussed. In addition, critical operation decision in alert condition in power plants discussed in details.
Abstract: Vibration analysis is the most important factor in preventive maintenance. Gas turbine vibration analysis is also one of the most challenging categories in most critical equipment monitoring systems. Utilities are heart of the process in big industrial plants like petrochemical zones. Vibration analysis methods and condition monitoring systems of this kind of equipment developed too much in recent years. On the other hand, too much operation condition consideration in this kind of equipment should be adjusted properly like inlet and outlet pressure and temperature for both turbine and compressor. In this paper the most important tools and hypothesis used for analyzing of gas turbine power plants discussed in details through a real case history related to an Alstom Typhoon gas turbine power plant in Iran oil industries. In addition, the basic principal of vibration behavior caused by mechanical unbalance in gas turbine rotor discussed in details.
Abstract: This paper deals with modeling and optimization of two NP-hard problems in production planning of flexible manufacturing system (FMS), part type selection problem and loading problem. The part type selection problem and the loading problem are strongly related and heavily influence the system’s efficiency and productivity. These problems have been modeled and solved simultaneously by using real coded genetic algorithms (RCGA) which uses an array of real numbers as chromosome representation. The novel proposed chromosome representation produces only feasible solutions which minimize a computational time needed by GA to push its population toward feasible search space or repair infeasible chromosomes. The proposed RCGA improves the FMS performance by considering two objectives, maximizing system throughput and maintaining the balance of the system (minimizing system unbalance). The resulted objective values are compared to the optimum values produced by branch-and-bound method. The experiments show that the proposed RCGA could reach near optimum solutions in a reasonable amount of time.
Abstract: Real-time or in-line process monitoring frameworks are designed to give early warnings for a fault along with meaningful identification of its assignable causes. In artificial intelligence and machine learning fields of pattern recognition various promising approaches have been proposed such as kernel-based nonlinear machine learning techniques. This work presents a kernel-based empirical monitoring scheme for batch type production processes with small sample size problem of partially unbalanced data. Measurement data of normal operations are easy to collect whilst special events or faults data are difficult to collect. In such situations, noise filtering techniques can be helpful in enhancing process monitoring performance. Furthermore, preprocessing of raw process data is used to get rid of unwanted variation of data. The performance of the monitoring scheme was demonstrated using three-dimensional batch data. The results showed that the monitoring performance was improved significantly in terms of detection success rate of process fault.
Abstract: Power quality is used to describe the degree of consistency of electrical energy expected from generation source to point of use. The term power quality refers to a wide variety of electromagnetic phenomena that characterize the voltage and current at a given time and at a given location on the power system. Power quality problems can be defined as problem that results in failure of customer equipments, which manifests itself as an economic burden to users, or produces negative impacts on the environment. Voltage stability, power factor, harmonics pollution, reactive power and load unbalance are some of the factors that affect the consistency or the quality level. This research proposal proposes to investigate and analyze the causes and effects of power quality to homes and industries in Sarawak. The increasing application of electronics equipment used in the industries and homes has caused a big impact on the power quality. Many electrical devices are now interconnected to the power network and it can be observed that if the power quality of the network is good, then any loads connected to it will run smoothly and efficiently. On the other hand, if the power quality of the network is bad, then loads connected to it will fail or may cause damage to the equipments and reduced its lifetime. The outcome of this research will enable better and novel solutions of poor power quality to small industries and reduce damage of electrical devices and products in the industries.
Abstract: This paper presents a simple three phase power flow
method for solution of three-phase unbalanced radial distribution
system (RDN) with voltage dependent loads. It solves a simple
algebraic recursive expression of voltage magnitude, and all the data
are stored in vector form. The algorithm uses basic principles of
circuit theory and can be easily understood. Mutual coupling between
the phases has been included in the mathematical model. The
proposed algorithm has been tested with several unbalanced radial
distribution networks and the results are presented in the article. 8-
bus and IEEE 13 bus unbalanced radial distribution system results
are in agreements with the literature and show that the proposed
model is valid and reliable.
Abstract: This paper presents an efficient approach to feeder
reconfiguration for power loss reduction and voltage profile
imprvement in unbalanced radial distribution systems (URDS). In
this paper Genetic Algorithm (GA) is used to obtain solution for
reconfiguration of radial distribution systems to minimize the losses.
A forward and backward algorithm is used to calculate load flows in
unbalanced distribution systems. By simulating the survival of the
fittest among the strings, the optimum string is searched by
randomized information exchange between strings by performing
crossover and mutation. Results have shown that proposed algorithm
has advantages over previous algorithms The proposed method is
effectively tested on 19 node and 25 node unbalanced radial
distribution systems.
Abstract: Software development has experienced remarkable progress in the past decade. However, due to the rising complexity and magnitude of the project the development productivity has not been consistently improved. By analyzing the latest ISBSG data repository with 4106 projects, we discovered that software development productivity has actually undergone irregular variations between the years 1995 and 2005. Considering the factors significant to the productivity, we found its variations are primarily caused by the variations of average team size and the unbalanced uses of the less productive language 3GL.
Abstract: This paper deals with the effect of a power transformer’s vector group on the basic voltage sag characteristics during unbalanced faults at a meshed or radial power network. Specifically, the propagation of voltage sags through a power transformer is studied with advanced short-circuit analysis. A smart method to incorporate this effect on analytical mathematical expressions is proposed. Based on this methodology, the positive effect of transformers of certain vector groups on the mitigation of the expected number of voltage sags per year (sag frequency) at the terminals of critical industrial customers can be estimated.
Abstract: Nonlinear and unbalance loads in three phase
networks create harmonics and losses. Active and passive filters are
used for elimination or reduction of these effects. Passive filters have
some limitations. For example, they are designed only for a specific
frequency and they may cause to resonance in the network at the
point of common coupling. The other drawback of a passive filter is
that the sizes of required elements are normally large. The active
filter can improve some of limitations of passive filter for example;
they can eliminate more than one harmonic and don't cause resonance
in the network. In this paper inverter analysis have been done
simultaneously in three phase and the RL impedance of the line have
been considered. A sliding mode control based on energy feedback of
capacitors is employed in the design with this method, the dynamic
speed of the filter is improved effectively and harmonics and load
unbalance is compensating quickly.
Abstract: An effective approach for unbalanced three-phase
distribution power flow solutions is proposed in this paper. The
special topological characteristics of distribution networks have been
fully utilized to make the direct solution possible. Two matrices–the
bus-injection to branch-current matrix and the branch-current to busvoltage
matrix– and a simple matrix multiplication are used to
obtain power flow solutions. Due to the distinctive solution
techniques of the proposed method, the time-consuming LU
decomposition and forward/backward substitution of the Jacobian
matrix or admittance matrix required in the traditional power flow
methods are no longer necessary. Therefore, the proposed method is
robust and time-efficient. Test results demonstrate the validity of the
proposed method. The proposed method shows great potential to be
used in distribution automation applications.
Abstract: Dynamic bandwidth allocation in EPONs can be
generally separated into inter-ONU scheduling and intra-ONU scheduling. In our previous work, the active intra-ONU scheduling
(AS) utilizes multiple queue reports (QRs) in each report message to cooperate with the inter-ONU scheduling and makes the granted
bandwidth fully utilized without leaving unused slot remainder (USR).
This scheme successfully solves the USR problem originating from the
inseparability of Ethernet frame. However, without proper setting of
threshold value in AS, the number of QRs constrained by the IEEE
802.3ah standard is not enough, especially in the unbalanced traffic
environment. This limitation may be solved by enlarging the threshold
value. The large threshold implies the large gap between the adjacent QRs, thus resulting in the large difference between the best granted bandwidth and the real granted bandwidth. In this paper, we integrate
AS with a cooperative prediction mechanism and distribute multiple
QRs to reduce the penalty brought by the prediction error.
Furthermore, to improve the QoS and save the usage of queue reports,
the highest priority (EF) traffic which comes during the waiting time is
granted automatically by OLT and is not considered in the requested
bandwidth of ONU. The simulation results show that the proposed
scheme has better performance metrics in terms of bandwidth
utilization and average delay for different classes of packets.
Abstract: DSTATCOM is one of the equipments for voltage sag mitigation in power systems. In this paper a new control method for balanced and unbalanced voltage sag mitigation using DSTATCOM is proposed. The control system has two loops in order to regulate compensator current and load voltage. Delayed signal cancellation has been used for sequence separation. The compensator should protect sensitive loads against different types of voltage sag. Performance of the proposed method is investigated under different types of voltage sags for linear and nonlinear loads. Simulation results show appropriate operation of the proposed control system.
Abstract: Rolling element bearings are widely used in industry,
especially where high load capacity is required. The diagnosis of
their conditions is essential matter for downtime reduction and saving
cost of maintenance. Therefore, an intensive analysis of frequency
spectrum of their faults must be carried out in order to determine the
main reason of the fault. This paper focus on a beating phenomena
observed in the waveform (time domain) of a cylindrical rolling
element bearing. The beating frequencies were not related to any
sources nearby the machine nor any other malfunctions (unbalance,
misalignment ...etc). More investigation on the spike energy and the
frequency spectrum indicated a problem with races of the bearing.
Multi-harmonics of the fundamental defects frequencies were
observed. Two of them were close to each other in magnitude those
were the source of the beating phenomena.
Abstract: The productivity of software development is one of the major concerns for project managers. Given the increasing complexity of the software being developed and the concomitant rise in the typical project size, the productivity has not consistently improved. By analyzing the latest release of ISBSG data repository with 4106 projects ever developed, we report on the factors found to significantly influence productivity, and present an original model for the estimation of productivity during project design. We further illustrate that software development productivity has experienced irregular variations between the years 1995 and 2005. Considering the factors significant to productivity, we found its variations are primarily caused by the variations of average team size for the development and the unbalanced use of the less productive development language 3GL.
Abstract: Because of architectural condition and structure application, sometimes mass source and stiffness source are not coincidence, and the structure is irregular. The structure is also might be asymmetric as an asymmetric bracing in plan which leads to unbalance distribution of stiffness or because of unbalance distribution of the mass. Both condition lead to eccentricity and torsion in the structure. The deficiency of ordinary code to evaluate the performance of steel structures against earthquake has been caused designing based on performance level or capacity spectrum be used. By using the mentioned methods it is possible to design a structure that its behavior against different earthquakes be predictive. In this article 5- story buildings with different percentage of asymmetric which is because of stiffness changes and kind of bracing (x and chevron bracing) have been designed. The static and dynamic nonlinear analysis under three acceleration recording has been done. Finally performance level of the structure has been evaluated.
Abstract: Point quad tree is considered as one of the most
common data organizations to deal with spatial data & can be used to
increase the efficiency for searching the point features. As the
efficiency of the searching technique depends on the height of the
tree, arbitrary insertion of the point features may make the tree
unbalanced and lead to higher time of searching. This paper attempts
to design an algorithm to make a nearly balanced quad tree. Point
pattern analysis technique has been applied for this purpose which
shows a significant enhancement of the performance and the results
are also included in the paper for the sake of completeness.
Abstract: A multiphase harmonic load flow algorithm is developed based on backward/forward sweep to examine the effects of various factors on the neutral to earth voltage (NEV), including unsymmetrical system configuration, load unbalance and harmonic injection. The proposed algorithm composes fundamental frequency and harmonic frequencies power flows. The algorithm and the associated models are tested on IEEE 13 bus system. The magnitude of NEV is investigated under various conditions of the number of grounding rods per feeder lengths, the grounding rods resistance and the grounding resistance of the in feeding source. Additionally, the harmonic injection of nonlinear loads has been considered and its influences on NEV under different conditions are shown.
Abstract: Active power filter continues to be a powerful tool to control harmonics in power systems thereby enhancing the power quality. This paper presents a fuzzy tuned PID controller based shunt active filter to diminish the harmonics caused by non linear loads like thyristor bridge rectifiers and imbalanced loads. Here Fuzzy controller provides the tuning of PID, based on firing of thyristor bridge rectifiers and variations in input rms current. The shunt APF system is implemented with three phase current controlled Voltage Source Inverter (VSI) and is connected at the point of common coupling for compensating the current harmonics by injecting equal but opposite filter currents. These controllers are capable of controlling dc-side capacitor voltage and estimating reference currents. Hysteresis Current Controller (HCC) is used to generate switching signals for the voltage source inverter. Simulation studies are carried out with non linear loads like thyristor bridge rectifier along with unbalanced loads and the results proved that the APF along with fuzzy tuned PID controller work flawlessly for different firing angles of non linear load.
Abstract: Linear induction motors are used in various industries
but they have some specific phenomena which are the causes for
some problems. The most important phenomenon is called end effect.
End effect decreases efficiency, power factor and output force and
unbalances the phase currents. This phenomenon is more important
in medium and high speeds machines. In this paper a factor, EEF , is
obtained by an accurate equivalent circuit model, to determine the
end effect intensity. In this way, all of effective design parameters on
end effect is described. Accuracy of this equivalent circuit model is
evaluated by two dimensional finite-element analysis using ANSYS.
The results show the accuracy of the equivalent circuit model.