Performance Evaluation of a Prioritized, Limited Multi-Server Processor-Sharing System That Includes Servers with Various Capacities

We present a prioritized, limited multi-server processor sharing (PS) system where each server has various capacities, and N (≥2) priority classes are allowed in each PS server. In each prioritized, limited server, different service ratio is assigned to each class request, and the number of requests to be processed is limited to less than a certain number. Routing strategies of such prioritized, limited multi-server PS systems that take into account the capacity of each server are also presented, and a performance evaluation procedure for these strategies is discussed. Practical performance measures of these strategies, such as loss probability, mean waiting time, and mean sojourn time, are evaluated via simulation. In the PS server, at the arrival (or departure) of a request, the extension (shortening) of the remaining sojourn time of each request receiving service can be calculated by using the number of requests of each class and the priority ratio. Utilising a simulation program which executes these events and calculations, the performance of the proposed prioritized, limited multi-server PS rule can be analyzed. From the evaluation results, most suitable routing strategy for the loss or waiting system is clarified.

Managers’ Capacity Building for Institutional Sustainability Performance

The Institutional Sustainability Performance (ISP) of State Universities and Colleges (SUCs) in the Philippines reveals the level of compliance and fidelity of the latter to the mandates of the state. This performance evaluation procedure aims to perpetually monitor and sustain the quality of services provided by the state institutions in the country. Importantly, the SUC level rating is one of the key indicators of the merit system adopted by the state to give incentives to government institutions. With the crucial role of the ISP and SUC level in the performance of an institution and in sustaining quality assurance, this study theorized that the top managers’ capacity to influence is the critical factor in meeting the expectations of the state. This study assessed the top managers’ capacity to influence. The hypothesis in this study proved that leadership style of top managers has significant relationship to the managers’ capacity to influence for institutional sustainability performance. Thus, the subjects of this study were restricted only to the State Universities and Colleges (SUC) that qualified in the top 20 Institutional Sustainability Performance; the digital governance performance, and the SUC leveling status nationwide. The top managers and their subordinates with doctorate of Bulacan State University and Bataan Peninsula State University whose programs have been consistently submitted to accreditation and were ranked Levels III and IV were subjected and participated to the study. This study assessed the top managers’ capacity to influence. The hypothesis in this study proved that leadership style of top managers has significant relationship to the managers’ capacity to influence for institutional sustainability performance. Thus, the subjects of this study were restricted only to the State Universities and Colleges (SUC) that qualified in the top 20 Institutional Sustainability Performance; the digital governance performance, and the SUC leveling status nationwide. The top managers and their subordinates with doctorate of Bulacan State University and Bataan Peninsula State University whose programs have been consistently submitted to accreditation and were ranked Levels III and IV were subjected and participated to the study.

Performance Evaluation of an Aboveground LNG Storage Tank Cover using Nondestructive and Destructive Tests

In this study, a new procedure for inspecting damages on LNG storage tanks was proposed with the use of structural diagnostic techniques: i.e., nondestructive inspection techniques such as macrography, the hammer sounding test, the Schmidt hammer test, and the ultrasonic pulse velocity test, and destructive inspection techniques such as the compressive strength test, the chloride penetration test, and the carbonation test. From the analysis of all the test results, it was concluded that the LNG storage tank cover was in good condition. Such results were also compared with the Korean concrete standard specifications and design values. In addition, the remaining life of the LNG storage tank was estimated by using existing models. Based on the results, an LNG storage tank cover performance evaluation procedure was suggested.