Abstract: Seismic isolators have been utilized around the world to protect the structures, nonstructural components and contents from the damaging effects of earthquakes. In Structural Engineering, seismic isolation is used for protecting buildings and its vibration-sensitive contents from earthquakes. Seismic isolation is a passive control system that lowers effective earthquake forces by utilizing flexible bearings. One of the most significant isolation systems is seismic isolators. In this paper, double pendulum type Teflon coated seismic isolators utilized in a city hospital project by Guris Construction and Engineering Co. Inc, located in Kutahya, Turkey, have been investigated. Totally, 498 seismic isolators were applied in the project. These isolators are double friction pendulum type seismic isolation devices. The review of current practices is also examined in this study. The focus of this study is related to the application of passive seismic isolation systems for buildings as practiced in Kutahya City Hospital Project. Based on the study, the acceleration at the top floor will be 0.18 g and it will decrease 0.01 g in every floor. Therefore, seismic isolators are very important for buildings located in earthquake zones.
Abstract: This research examines the performance of a hybrid passive control device for enhancing the seismic response of steel frame structures. The device design comprises a damper which employs a viscoelastic material to control both shear and axial strain. In the design, energy is dissipated through the shear strain of a two-layer system of viscoelastic pads which are located between steel plates. In addition, viscoelastic blocks have been included on either side of the main shear damper which obtains compressive strains in the viscoelastic blocks. These dampers not only dissipate energy but also increase the stiffness of the steel frame structure, and the degree to which they increase the stiffness may be controlled by the size and shape. In this research, the cyclical behavior of the damper was examined both experimentally and numerically with finite element modeling. Cyclic loading results of the finite element modeling reveal fundamental characteristics of this hybrid viscoelastic damper. The results indicate that incorporating a damper of the design can significantly improve the seismic performance of steel frame structures.
Abstract: Determination of optimal parameters of a passive
control system device is the primary objective of this study.
Expanding upon the use of control devices in wind and earthquake
hazard reduction has led to development of various control systems.
The advantage of non-linearity characteristics in a passive control
device and the optimal control method using LQR algorithm are
explained in this study. Finally, this paper introduces a simple
approach to determine optimum parameters of a nonlinear viscous
damper for vibration control of structures. A MATLAB program is
used to produce the dynamic motion of the structure considering the
stiffness matrix of the SDOF frame and the non-linear damping
effect. This study concluded that the proposed system (variable
damping system) has better performance in system response control
than a linear damping system. Also, according to the energy
dissipation graph, the total energy loss is greater in non-linear
damping system than other systems.
Abstract: In the present paper, active control system is used in
different heights of the building and the most effective part was
studied where the active control system is applied. The mathematical
model of the building is established in MATLAB and in order to
active control the system FLC method was used. Three different
locations of the building are chosen to apply active control system,
namely at the lowest story, the middle height of the building, and at
the highest point of the building with TMD system. The equation of
motion was written for high rise building and it was solved by statespace
method. Also passive control was used with Tuned Mass
Damper (TMD) at the top floor of the building to show the robustness
of FLC method when compared with passive control system.