Abstract: The objective of this work is to carryout critical
comparison of different actuation mechanisms like electrostatic,
thermal, piezoelectric, and magnetic with reference to a micro
cantilever. The relevant parameters like force generated,
displacement are compared in actuation methods. With these results,
helps in choosing the best actuation method for a particular
application. In this study, Comsol/Multiphysics software is used.
Modeling and simulation is done by considering the micro cantilever
of same dimensions as an actuator using all the above mentioned
actuation techniques. In addition to their small size, micro actuators
consume very little power and are capable of accurate results. In this
work, a comparison of actuation mechanisms is done to decide the
efficient system in micro domain.
Abstract: The porous silicon (PS), formed from the anodization
of a p+ type substrate silicon, consists of a network organized in a
pseudo-column as structure of multiple side ramifications. Structural
micro-topology can be interpreted as the fraction of the interconnected
solid phase contributing to thermal transport. The
reduction of dimensions of silicon of each nanocristallite during the
oxidation induced a reduction in thermal conductivity. Integration of
thermal sensors in the Microsystems silicon requires an effective
insulation of the sensor element. Indeed, the low thermal conductivity
of PS consists in a very promising way in the fabrication of integrated
thermal Microsystems.In this work we are interesting in the
measurements of thermal conductivity (on the surface and in depth)
of PS by the micro-Raman spectroscopy. The thermal conductivity is
studied according to the parameters of anodization (initial doping and
current density. We also, determine porosity of samples by
spectroellipsometry.
Abstract: Iran is one of the greatest producers of date in the
world. However due to lack of information about its viscoelastic
properties, much of the production downgraded during harvesting
and postharvesting processes. In this study the effect of temperature
and moisture content of product were investigated on stress
relaxation characteristics. Therefore, the freshly harvested date
(kabkab) at tamar stage were put in controlled environment chamber
to obtain different temperature levels (25, 35, 45, and 55 0C) and
moisture contents (8.5, 8.7, 9.2, 15.3, 20, 32.2 %d.b.). A texture
analyzer TAXT2 (Stable Microsystems, UK) was used to apply
uniaxial compression tests. A chamber capable to control temperature
was designed and fabricated around the plunger of texture analyzer to
control the temperature during the experiment. As a new approach a
CCD camera (A4tech, 30 fps) was mounted on a cylindrical glass
probe to scan and record contact area between date and disk.
Afterwards, pictures were analyzed using image processing toolbox
of Matlab software. Individual date fruit was uniaxially compressed
at speed of 1 mm/s. The constant strain of 30% of thickness of date
was applied to the horizontally oriented fruit. To select a suitable
model for describing stress relaxation of date, experimental data were
fitted with three famous stress relaxation models including the
generalized Maxwell, Nussinovitch, and Pelege. The constant in
mentioned model were determined and correlated with temperature
and moisture content of product using non-linear regression analysis.
It was found that Generalized Maxwell and Nussinovitch models
appropriately describe viscoelastic characteristics of date fruits as
compared to Peleg mode.
Abstract: This paper presented a modified efficient inductive
powering link based on ASK modulator and proposed efficient class-
E power amplifier. The design presents the external part which is
located outside the body to transfer power and data to the implanted
devices such as implanted Microsystems to stimulate and monitoring
the nerves and muscles. The system operated with low band
frequency 10MHZ according to industrial- scientific – medical (ISM)
band to avoid the tissue heating. For external part, the modulation
index is 11.1% and the modulation rate 7.2% with data rate 1 Mbit/s
assuming Tbit = 1us. The system has been designed using 0.35-μm
fabricated CMOS technology. The mathematical model is given and
the design is simulated using OrCAD P Spice 16.2 software tool and
for real-time simulation, the electronic workbench MULISIM 11 has
been used.
Abstract: What influences microsystems (MEMS) and nanosystems (NEMS) innovation teams apart from technology complexity? Based on in-depth interviews with innovators, this research explores the key influences on innovation teams in the early phases of MEMS/NEMS. Projects are rare and may last from 5 to 10 years or more from idea to concept. As fundamental technology development in MEMS/NEMS is highly complex and interdisciplinary by involving expertise from different basic and engineering disciplines, R&D is rather a 'testing of ideas' with many uncertainties than a clearly structured process. The purpose of this study is to explore the innovation teams- environment and give specific insights for future management practices. The findings are grouped into three major areas: people, know-how and experience, and market. The results highlight the importance and differences of innovation teams- composition, transdisciplinary knowledge, project evaluation and management compared to the counterparts from new product development teams.
Abstract: This paper presented a proposed design for
transcutaneous inductive powering links. The design used to transfer
power and data to the implanted devices such as implanted
Microsystems to stimulate and monitoring the nerves and muscles.
The system operated with low band frequency 13.56 MHZ according
to industrial- scientific – medical (ISM) band to avoid the tissue
heating. For external part, the modulation index is 13 % and the
modulation rate 7.3% with data rate 1 Mbit/s assuming Tbit=1us. The
system has been designed using 0.35-μm fabricated CMOS
technology. The mathematical model is given and the design is
simulated using OrCAD P Spice 16.2 software tool and for real-time
simulation the electronic workbench MULISIM 11 has been used.
The novel circular plane (pancake) coils was simulated using
ANSOFT- HFss software.