Abstract: Retinal prostheses have been successful in eliciting
visual responses in implanted subjects. As these prostheses progress,
one of their major limitations is the need for increased resolution. As
an alternative to increasing the number of electrodes, virtual
electrodes may be used to increase the effective resolution of current
electrode arrays. This paper presents a virtual electrode technique
based upon time-offsets between stimuli. Two adjacent electrodes are
stimulated with identical pulses with too short of pulse widths to
activate a neuron, but one has a time offset of one pulse width. A
virtual electrode of twice the pulse width was then shown to appear in
the center, with a total width capable of activating a neuron. This can
be used in retinal implants by stimulating electrodes with pulse
widths short enough to not elicit responses in neurons, but with their
combined pulse width adequate to activate a neuron in between them.
Abstract: In a transcutanious inductive coupling of a biomedical
implant, a new formula is given for the study of the Radio Frequency
power attenuation by the biological tissue. The loss of the signal
power is related to its interaction with the biological tissue and the
composition of this one. A confrontation with the practical
measurements done with a synthetic muscle into a Faraday cage,
allowed a checking of the obtained theoretical results. The
supply/data transfer systems used in the case of biomedical implants,
can be well dimensioned by taking in account this type of power
attenuation.
Abstract: The aim of this retrospective study was to evaluate the
parameters of dental implants such as patient gender, number of
implant, failed implant before prosthetic restorations and failed
implant after implantation and failed implant after prosthetic
restorations. 135 male and 99 female patients, total 234 implant
patients which have been treated with 450 implant between 2005-
2009 years in GATA Haydarpasa Training Hospital Dental Service.
Twelve implants were failed before prosthetic restorations. Four
implant were failed after fixed prosthetic restorations. Cumulative
survival rate after prostheses were 97.56 % during 6 years period.
Abstract: An implant elicits a biological response in the
surrounding tissue which determines the acceptance and long-term
function of the implant. Dental implants have become one of the
main therapy methods in clinic after teeth lose. A successful implant
is in contact with bone and soft tissue represent by fibroblasts. In our
study we focused on the interaction between six different chemically
and physically modified titanium implants (Tis-MALP, Tis-O, Tis-
OA, Tis-OPAAE, Tis-OZ, Tis-OPAE) with alveolar fibroblasts as
well as with five type of microorganisms (S. epidermis, S.mutans, S.
gordonii, S. intermedius, C.albicans). The analysis of microorganism
adhesion was determined by CFU (colony forming unite) and biofilm
formation. The presence of α3β1 and vinculin expression on alveolar
fibroblasts was demonstrated using phospho specific cell based
ELISA (PACE). Alveolar fibroblasts have the highest expression of
these proteins on Tis-OPAAE and Tis-OPAE. It corresponds with
results from bacterial adhesion and biofilm formation and it was
related to the lowest production of collagen I by alveolar fibroblasts
on Tis-OPAAE titanium disc.
Abstract: Magnesium is used implant material potentially for
non-toxicity to the human body. Due to the excellent
bio-compatibility, Mg alloys is applied to implants avoiding removal
second surgery. However, it is found commercial magnesium alloys
including aluminum has low corrosion resistance, resulting
subcutaneous gas bubbles and consequently the approach as
permanent bio-materials. Generally, Aluminum is known to pollution
substance, and it raises toxicity to nervous system. Therefore
especially Mg-35Zn-3Ca alloy is prepared for new biodegradable
materials in this study. And the pulsed power is used in
constant-current mode of DC power kinds of anodization. Based on
the aforementioned study, it examines corrosion resistance and
biocompatibility by effect of current and frequency variation. The
surface properties and thickness were compared using scanning
electronic microscopy. Corrosion resistance was assessed via
potentiodynamic polarization and the effect of oxide layer on the body
was assessed cell viability. Anodized Mg-35Zn-3Ca alloy has good
biocompatibility in vitro by current and frequency variation.
Abstract: RFID (Radio Frequency IDentification) system has
been widely used in our life, such as transport systems, passports,
automotive, animal tracking, human implants, library, and so on.
However, the RFID authentication protocols between RF (Radio
Frequency) tags and the RF readers have been bring about various
privacy problems that anonymity of the tags, tracking, eavesdropping,
and so on. Many researchers have proposed the solution of the
problems. However, they still have the problem, such as location
privacy, mutual authentication. In this paper, we show the problems of
the previous protocols, and then we propose a more secure and
efficient RFID authentication protocol.
Abstract: In this study, stress distributions on dental implants
made of functionally graded biomaterials (FGBM) are investigated
numerically. The implant body is considered to be subjected to axial
compression loads. Numerical problem is assumed to be 2D, and
ANSYS commercial software is used for the analysis. The cross
section of the implant thread varies as varying the height (H) and the
width (t) of the thread. According to thread dimensions of implant
and material properties of FGBM, equivalent stress distribution on
the implant is determined and presented with contour plots along
with the maximum equivalent stress values. As a result, with
increasing material gradient parameter (n), the equivalent stress
decreases, but the minimum stress distribution increases. Maximum
stress values decrease with decreasing implant radius (r). Maximum
von Mises stresses increases with decreasing H when t is constant.
On the other hand, the stress values are not affected by variation of t
in the case of H = constant.
Abstract: To understand complex living system an effort has
made by mechanical engineers and dentists to deliver prompt
products and services to patients concerned about their aesthetic look.
Since two decades various bracket systems have designed involving
techniques like milling, injection molding which are technically not
flexible for the customized dental product development. The aim of
this paper to design, develop a customized system which is
economical and mainly emphasizes the expertise design and
integration of engineering and dental fields. A custom made selfadjustable
lingual bracket and customized implants are designed and
developed using computer aided design (CAD) and rapid prototyping
technology (RPT) to improve the smiles and to overcome the
difficulties associated with conventional ones. Lengthy orthodontic
treatment usually not accepted by the patients because the patient
compliance is lost. Patient-s compliance can be improved by
facilitating faster tooth movements by designing a localized dental
vibrator using advanced engineering principles.
Abstract: A series of Ti based shape memory alloys with
composition of Ti50Ni49Cr1, Ti50Ni47Cr3 and Ti50Ni45Cr5 were
developed by vacuum arc-melting under a purified argon atmosphere.
The histometric and corrosion evaluation of Ti-Ni-Cr shape memory
alloys have been considered in this research work. The alloys were
developed by vacuum arc melting and implanted subcutaneously in
rabbits for 4, 8 and 12 weeks. Metallic implants were embedded in
order to determine the outcome of implantation on histometric and
corrosion evaluation of Ti-Ni-Cr metallic strips. Encapsulating
membrane formation around the alloys was minimal in the case of all
materials. After histomorphometric analyses it was possible to
demonstrate that there were no statistically significant differences
between the materials. Corrosion rate was also determined in this
study which is within acceptable range. The results showed the Ti-
Ni-Cr alloy was neither cytotoxic, nor have any systemic reaction on
living system in any of the test performed. Implantation shows good
compatibility and a potential of being used directly in vivo system.
Abstract: The estrus female Etawah cross bred goats were
synchronized estrus by controlled internal drug release (CIDR)
implants for 10 days combined with PGF2α injection, and continued
by artificial insemination (AI) within the hours of 24 period. Vaginal
epithelium was taken to determine estrus cycle of the goats without
estrus synchronization. The estrus responds (the puffy of vulva and
vaginal pH) and percentage of pregnancy were investigated. The data
were analyzed descriptively and Independent Sample T-Test. The
results showed that the puffy of vulva and vaginal pH were
significantly different in synchronized estrus goats and control goats
(2.18 ± 0.33 cm vs. 1.20 ± 0.16 cm and 8.55 ± 0.63 vs. 8.22 ± 0.22).
Percentage of pregnancy was higher in synchronized estrus goats
(73.33%) than in control (53.3%). Estrus synchronization by using
CIDR implants and PGF2, continued by AI was effective to improve
reproduction performance of Etawah cross bred goats.
Abstract: In this study, the powders of Ni and Ti with 50.5 at.%
Ni for 12 h were blended and cold pressed at the different pressures
(50, 75 and100 MPa).The porous product obtained after Ni-Ti
compacts were synthesized by SHS (self-propagating hightemperature
synthesis) in the different preheating temperatures (200,
250 and 300oC) and heating rates (30, 60 and 90oC/min). The effects
of the pressure, preheating temperature and heating rate were
investigated on biocompatibility in vivo. The porosity in the
synthesized products was in the range of 50.7–59.7 vol. %. The
pressure, preheating temperature and heating rate were found to have
an important effect on the biocompatibility in-vivo of the synthesized
products. Max. fibrotic tissue within the porous implant was found in
vivo periods (6 months), in which compacting pressure 100MPa.
Abstract: Rapid Prototyping (RP) is a technology that produces models and prototype parts from 3D CAD model data, CT/MRI scan data, and model data created from 3D object digitizing systems. There are several RP process like Stereolithography (SLA), Solid Ground Curing (SGC), Selective Laser Sintering (SLS), Fused Deposition Modeling (FDM), 3D Printing (3DP) among them SLS and FDM RP processes are used to fabricate pattern of custom cranial implant. RP technology is useful in engineering and biomedical application. This is helpful in engineering for product design, tooling and manufacture etc. RP biomedical applications are design and development of medical devices, instruments, prosthetics and implantation; it is also helpful in planning complex surgical operation. The traditional approach limits the full appreciation of various bony structure movements and therefore the custom implants produced are difficult to measure the anatomy of parts and analyze the changes in facial appearances accurately. Cranioplasty surgery is a surgical correction of a defect in cranial bone by implanting a metal or plastic replacement to restore the missing part. This paper aims to do a comparative study on the dimensional error of CAD and SLS RP Models for reconstruction of cranial defect by comparing the virtual CAD with the physical RP model of a cranial defect.