Abstract: The perfect operation of common Active Filters is depended on accuracy of identification system distortion. Also, using a suitable method in current injection and reactive power compensation, leads to increased filter performance. Due to this fact, this paper presents a method based on predictive current control theory in shunt active filter applications. The harmonics of the load current is identified by using o–d–q reference frame on load current and eliminating the DC part of d–q components. Then, the rest of these components deliver to predictive current controller as a Threephase reference current by using Park inverse transformation. System is modeled in discreet time domain. The proposed method has been tested using MATLAB model for a nonlinear load (with Total Harmonic Distortion=20%). The simulation results indicate that the proposed filter leads to flowing a sinusoidal current (THD=0.15%) through the source. In addition, the results show that the filter tracks the reference current accurately.
Abstract: This paper proposes a feed-forward control in
resonant dc link inverter. The feed-forward control configuration is
based on synchronous sigma-delta modulation. The simulation
results showing the proposed technique can reject non-ideal dc bus
improving the total harmonic distortion.
Abstract: Nowadays in applications of renewable energy sources
it is important to develop powerful and energy-saving photovoltaic
converters and to keep the prescriptions of the standards. In grid
connected PV converters the obvious solution to increase the
efficiency is to reduce the switching losses. Our new developed
control method reduces the switching losses and keeps the limitations
of the harmonic distortion standards. The base idea of the method is
the utilization of 3-state control causing discontinuous current mode
at low input power. In the following sections the control theory, the
realizations and the simulation results are presented.
Abstract: This paper proposes different methods for estimation
of the harmonic currents of the single-phase diode bridge rectifier. Both simple and advanced methods are compared and the models are
put into a context of practical use for calculating the harmonic distortion in a typical application. Finally, the different models are
compared to measurements of a real application and convincing results are achieved.
Abstract: This paper presents a low-voltage low-power differential linear transconductor with near rail-to-rail input swing. Based on the current-mirror OTA topology, the proposed transconductor combines the Flipped Voltage Follower (FVF) technique to linearize the transconductor behavior that leads to class- AB linear operation and the virtual transistor technique to lower the effective threshold voltages of the transistors which offers an advantage in terms of low supply requirement. Design of the OTA has been discussed. It operates at supply voltages of about ±0.8V. Simulation results for 0.18μm TSMC CMOS technology show a good input range of 1Vpp with a high DC gain of 81.53dB and a total harmonic distortion of -40dB at 1MHz for an input of 1Vpp. The main aim of this paper is to present and compare new OTA design with high transconductance, which has a potential to be used in low voltage applications.
Abstract: Power Factor (PF) is one of the most important parameters in the electrical systems, especially in the water pumping station. The low power factor value of the water pumping stations causes penalty for the electrical bill. There are many methods use for power factor improvement. Each one of them uses a capacitor on the electrical power network. The position of the capacitors is varied depends on many factors such as; voltage level and capacitors rating. Adding capacitors on the motor terminals increase the supply power factor from 0.8 to more than 0.9 but these capacitors cause some problems for the electrical grid network, such as increasing the harmonic contents of the grid line voltage. In this paper the effects of using capacitors in the water pumping stations to improve the power factor value on the harmonic contents of the electrical grid network are studied. One of large water pumping stations in Kafr El-Shikh Governorate in Egypt was used, as a case study. The effect of capacitors on the line voltage harmonic contents is measured. The station uses capacitors to improve the PF values at the 1 lkv grid network. The power supply harmonics values are measured by a power quality analyzer at different loading conditions. The results showed that; the capacitors improved the power factor value of the feeder and its value increased than 0.9. But the THD values are increased by adding these capacitors. The harmonic analysis showed that; the 13th, 17th, and 19th harmonics orders are increased also by adding the capacitors.
Abstract: Active power filter continues to be a powerful tool to control harmonics in power systems thereby enhancing the power quality. This paper presents a fuzzy tuned PID controller based shunt active filter to diminish the harmonics caused by non linear loads like thyristor bridge rectifiers and imbalanced loads. Here Fuzzy controller provides the tuning of PID, based on firing of thyristor bridge rectifiers and variations in input rms current. The shunt APF system is implemented with three phase current controlled Voltage Source Inverter (VSI) and is connected at the point of common coupling for compensating the current harmonics by injecting equal but opposite filter currents. These controllers are capable of controlling dc-side capacitor voltage and estimating reference currents. Hysteresis Current Controller (HCC) is used to generate switching signals for the voltage source inverter. Simulation studies are carried out with non linear loads like thyristor bridge rectifier along with unbalanced loads and the results proved that the APF along with fuzzy tuned PID controller work flawlessly for different firing angles of non linear load.
Abstract: This paper presents a pulse doubling technique in a 12-pulse ac-dc converter which supplies direct torque controlled motor drives (DTCIMD-s) in order to have better power quality conditions at the point of common coupling. The proposed technique increases the number of rectification pulses without significant changes in the installations and yields in harmonic reduction in both ac and dc sides. The 12-pulse rectified output voltage is accomplished via two paralleled six-pulse ac-dc converters each of them consisting of three-phase diode bridge rectifier. An autotransformer is designed to supply the rectifiers. The design procedure of magnetics is in a way such that makes it suitable for retrofit applications where a six-pulse diode bridge rectifier is being utilized. Independent operation of paralleled diode-bridge rectifiers, i.e. dc-ripple re-injection methodology, requires a Zero Sequence Blocking Transformer (ZSBT). Finally, a tapped interphase reactor is connected at the output of ZSBT to double the pulse numbers of output voltage up to 24 pulses. The aforementioned structure improves power quality criteria at ac mains and makes them consistent with the IEEE-519 standard requirements for varying loads. Furthermore, near unity power factor is obtained for a wide range of DTCIMD operation. A comparison is made between 6- pulse, 12-pulse, and proposed converters from view point of power quality indices. Results show that input current total harmonic distortion (THD) is less than 5% for the proposed topology at various loads.
Abstract: Direct Torque Control is a control technique in AC
drive systems to obtain high performance torque control. The
conventional DTC drive contains a pair of hysteresis comparators.
DTC drives utilizing hysteresis comparators suffer from high torque
ripple and variable switching frequency. The most common solution
to those problems is to use the space vector depends on the reference
torque and flux. In this Paper The space vector modulation technique
(SVPWM) is applied to 2 level inverter control in the proposed
DTC-based induction motor drive system, thereby dramatically
reducing the torque ripple. Then the controller based on space vector
modulation is designed to be applied in the control of Induction
Motor (IM) with a three-level Inverter. This type of Inverter has
several advantages over the standard two-level VSI, such as a greater
number of levels in the output voltage waveforms, Lower dV/dt, less
harmonic distortion in voltage and current waveforms and lower
switching frequencies. This paper proposes a general SVPWM
algorithm for three-level based on standard two-level SVPWM. The
proposed scheme is described clearly and simulation results are
reported to demonstrate its effectiveness. The entire control scheme is
implemented with Matlab/Simulink.
Abstract: A new low-voltage floating gate MOSFET (FGMOS)
based squarer using square law characteristic of the FGMOS is
proposed in this paper. The major advantages of the squarer are simplicity,
rail-to-rail input dynamic range, low total harmonic distortion,
and low power consumption. The proposed circuit is biased without
body effect. The circuit is designed and simulated using SPICE in
0.25μm CMOS technology. The squarer is operated at the supply
voltages of ±0.75V . The total harmonic distortion (THD) for the
input signal 0.75Vpp at 25 KHz, and maximum power consumption
were found to be less than 1% and 319μW respectively.
Abstract: This paper present the harmonic elimination of hybrid
multilevel inverters (HMI) which could be increase the number of
output voltage level. Total Harmonic Distortion (THD) is one of the
most important requirements concerning performance indices.
Because of many numbers output levels of HMI, it had numerous
unknown variables of eliminate undesired individual harmonic and
THD nonlinear equations set. Optimized harmonic stepped waveform
(OHSW) is solving switching angles conventional method, but most
complicated for solving as added level. The artificial intelligent
techniques are deliberation to solve this problem. This paper presents
the Particle Swarm Optimization (PSO) technique for solving
switching angles to get minimum THD and eliminate undesired
individual harmonics of 15-levels hybrid multilevel inverters.
Consequently it had many variables and could eliminate numerous
harmonics. Both advantages including high level of inverter and
Particle Swarm Optimization (PSO) are used as powerful tools for
harmonics elimination.
Abstract: Properly sized capacitor banks are connected across induction motors for several reasons including power factor correction, reducing distortions, increasing capacity, etc. Total harmonic distortion (THD) and power factor (PF) are used in such cases to quantify the improvements obtained through connection of the external capacitor banks. On the other hand, one of the methods for assessing the motor internal condition is by the use of Park-s pattern analysis. In spite of taking adequate precautionary measures, the capacitor banks may sometimes malfunction. Such a minor fault in the capacitor bank is often not apparently discernible. This may however, give rise to substantial degradation of power factor correction performance and may also damage the supply profile. The case is more severe with the fact that the Park-s pattern gets distorted due to such external capacitor faults, and can give anomalous results about motor internal fault analyses. The aim of this paper is to present simulation and hardware laboratory test results to have an understanding of the anomalies in harmonic distortion and Park-s pattern analyses in induction motors due to capacitor bank defects.
Abstract: Multi-level voltage source inverters offer several
advantages such as; derivation of a refined output voltage with
reduced total harmonic distortion (THD), reduction of voltage ratings
of the power semiconductor switching devices and also the reduced
electro-magnetic-interference problems etc. In this paper, new
carrier-overlapped phase-disposition or sub-harmonic sinusoidal
pulse width modulation (CO-PD-SPWM) and also the carrieroverlapped
phase-disposition space vector modulation (CO-PDSVPWM)
schemes for a six-level diode-clamped inverter topology
are proposed. The principle of the proposed PWM schemes is similar
to the conventional PD-PWM with a little deviation from it in the
sense that the triangular carriers are all overlapped. The overlapping
of the triangular carriers on one hand results in an increased number
of switchings, on the other hand this facilitates an improved spectral
performance of the output voltage. It is demonstrated through
simulation studies that the six-level diode-clamped inverter with the
use of CO-PD-SPWM and CO-PD-SVPWM proposed in this paper is
capable of generating multiple levels in its output voltage. The
advantages of the proposed PWM schemes can be derived to benefit,
especially at lower modulation indices of the inverter and hence this
aspect of the proposed PWM schemes can be well exploited in high
power applications requiring low speeds of operation of the drive.
Abstract: Active Power Filters (APFs) are today the most
widely used systems to eliminate harmonics compensate power
factor and correct unbalanced problems in industrial power plants.
We propose to improve the performances of conventional APFs by
using artificial neural networks (ANNs) for harmonics estimation.
This new method combines both the strategies for extracting the
three-phase reference currents for active power filters and DC link
voltage control method. The ANNs learning capabilities to
adaptively choose the power system parameters for both to compute
the reference currents and to recharge the capacitor value requested
by VDC voltage in order to ensure suitable transit of powers to
supply the inverter. To investigate the performance of this
identification method, the study has been accomplished using
simulation with the MATLAB Simulink Power System Toolbox. The
simulation study results of the new (SAPF) identification technique
compared to other similar methods are found quite satisfactory by
assuring good filtering characteristics and high system stability.
Abstract: This paper presents a fuzzy logic controlled shunt
active power filter used to compensate for harmonic distortion in three-phase four-wire systems. The shunt active filter employs a
simple method for the calculation of the reference compensation current based of Fast Fourier Transform. This presented filter is able
to operate in both balanced and unbalanced load conditions. A fuzzy
logic based current controller strategy is used to regulate the filter current and hence ensure harmonic free supply current. The validity
of the presented approach in harmonic mitigation is verified via
simulation results of the proposed test system under different loading
conditions.
Abstract: This paper presents a novel sinusoidal modulation
scheme that features least correlated noise and high linearity. The
modulation circuit, which is composed of a quantizer, a resonator, and
a comparator, is capable of eliminating correlated modulation noise
while doing modulation. The proposed modulation scheme combined
with the linear quadratic optimal control is applied to a single-phase
voltage source inverter and validated with the experiment results. The
experiments show that the inverter supplies stable 60Hz 110V AC
power with a total harmonic distortion of less than 1%, under the DC
input variation from 190 V to 300 V and the output power variation
from 0 to 600 W.
Abstract: A 10bit, 40 MSps, sample and hold, implemented in 0.18-μm CMOS technology with 3.3V supply, is presented for application in the front-end stage of an analog-to-digital converter. Topology selection, biasing, compensation and common mode feedback are discussed. Cascode technique has been used to increase the dc gain. The proposed opamp provides 149MHz unity-gain bandwidth (wu), 80 degree phase margin and a differential peak to peak output swing more than 2.5v. The circuit has 55db Total Harmonic Distortion (THD), using the improved fully differential two stage operational amplifier of 91.7dB gain. The power dissipation of the designed sample and hold is 4.7mw. The designed system demonstrates relatively suitable response in different process, temperature and supply corners (PVT corners).
Abstract: As wind, solar and other clean and green energy
sources gain popularity worldwide, engineers are seeking ways to
make renewable energy systems more affordable and to integrate
them with existing ac power grids. In the present paper an attempt
has been made for integrating the PV arrays to the smart nano grid
using an artificial intelligent (AI) based solar powered cascade multilevel
inverter. The AI based controller switching scheme has been
used for improving the power quality by reducing the Total Harmonic
Distortion (THD) of the multi-level inverter output voltage.
Abstract: In this paper, we consider a designed and
implemented phase-cutting dimmer. In fact, the dimmer is closed
loop and a microcontroller calculates and then regulates the firing
delay angles of each channel. Depending on the firing angle, the
harmonic distortion in the input current will not comply with
international standards, such as IEC 61000-3-2 (class C equipments).
For solving this problem, eight harmonic compensators have been
added to the dimmer. So, the proposed dimmer has a little harmonic
distortion in the input current whereas conventional phase-cutting
dimmers are not so. Sensitivity and removed THD of the proposed
dimmer will be presented.
Abstract: Nowadays Multilevel inverters are widely using in various applications. Modulation strategy at fundamental switching frequency like, SHEPWM is prominent technique to eliminate lower order of harmonics with less switching losses and better harmonic profile. The equations which are formed by SHE are highly nonlinear transcendental in nature, there may exist single, multiple or even no solutions for a particular MI. However, some loads such as electrical drives, it is required to operate in whole range of MI. In order to solve SHE equations for whole range of MI, intelligent techniques are well suited to solve equations so as to produce lest %THDV. Hence, this paper uses Continuous genetic algorithm for minimising harmonics. This paper also presents wavelet based analysis of harmonics. The developed algorithm is simulated and %THD from FFT analysis and Wavelet analysis are compared. MATLAB programming environment and SIMULINK models are used whenever necessary.