Abstract: Speaker recognition is performed in high Additive White Gaussian Noise (AWGN) environments using principals of Computational Auditory Scene Analysis (CASA). CASA methods often classify sounds from images in the time-frequency (T-F) plane using spectrograms or cochleargrams as the image. In this paper atomic decomposition implemented by matching pursuit performs a transform from time series speech signals to the T-F plane. The atomic decomposition creates a sparsely populated T-F vector in “weight space” where each populated T-F position contains an amplitude weight. The weight space vector along with the atomic dictionary represents a denoised, compressed version of the original signal. The arraignment or of the atomic indices in the T-F vector are used for classification. Unsupervised feature learning implemented by a sparse autoencoder learns a single dictionary of basis features from a collection of envelope samples from all speakers. The approach is demonstrated using pairs of speakers from the TIMIT data set. Pairs of speakers are selected randomly from a single district. Each speak has 10 sentences. Two are used for training and 8 for testing. Atomic index probabilities are created for each training sentence and also for each test sentence. Classification is performed by finding the lowest Euclidean distance between then probabilities from the training sentences and the test sentences. Training is done at a 30dB Signal-to-Noise Ratio (SNR). Testing is performed at SNR’s of 0 dB, 5 dB, 10 dB and 30dB. The algorithm has a baseline classification accuracy of ~93% averaged over 10 pairs of speakers from the TIMIT data set. The baseline accuracy is attributable to short sequences of training and test data as well as the overall simplicity of the classification algorithm. The accuracy is not affected by AWGN and produces ~93% accuracy at 0dB SNR.
Abstract: Vector-borne diseases are transmitted to humans by mosquitos, sandflies, bugs, ticks, and other vectors. Some are re-transmitted between vectors, if the infected human has a new contact when his levels of infection are high. The vector is infected for lifetime and can transmit infectious diseases not only between humans but also from animals to humans. Some vector borne diseases are very disabling and globally account for more than one million deaths worldwide. The mosquitoes from the complex Culex pipiens sl. are the most abundant in Portugal, and we dispose in this moment of a data set from the surveillance program that has been carried on since 2006 across the country. All mosquitos’ species are included, but the large coverage of Culex pipiens sl. and its importance for public health make this vector an interesting candidate to assess risk of disease amplification. This work focus on ports and airports identified as key areas of high density of vectors. Mosquitoes being ectothermic organisms, the main factor for vector survival and pathogen development is temperature. Minima and maxima local air temperatures for each area of interest are averaged by month from data gathered on a daily basis at the national network of meteorological stations, and interpolated in a geographic information system (GIS). The range of temperatures ideal for several pathogens are known and this work shows how to use it with the meteorological data in each port and airport facility, to focus an efficient implementation of countermeasures and reduce simultaneously risk transmission and mitigation costs. The results show an increased alert with decreasing latitude, which corresponds to higher minimum and maximum temperatures and a lower amplitude range of the daily temperature.
Abstract: The P300 from Event related potential (ERP) explains the psycho-physiological phenomenon in human body. The present study aims to identify the differences of amplitude and latency of P300 component from auditory stimuli, between ambiversion and extraversion types of personality. Ambivert (N=20) and extravert (N=20) undergoing ERP recording at the Hospital Universiti Sains Malaysia (HUSM) laboratory. Electroencephalogram data was recorded with oddball paradigm, counting auditory standard and target tones, from nine electrode sites (Fz, Cz, Pz, T3, T4, T5, T6, P3 and P4) by using the 128 HydroCel Geodesic Sensor Net. The P300 latency of the target tones at all electrodes were insignificant. Similarly, the P300 latency of the standard tones were also insignificant except at Fz and T3 electrode. Likewise, the P300 amplitude of the target and standard tone in all electrode sites were insignificant. Extravert and ambivert indicate similar characteristic in cognition processing from auditory task.
Abstract: Ground Penetrating Radar (GPR) is one of the most effective electromagnetic techniques for non-destructive non-invasive subsurface features investigation. Water leak from pipelines is the most common undesirable reason of potable water losses. Rapid detection of such losses is going to enhance the use of the Water Distribution Networks (WDN) and decrease threatens associated with water mains leaks. In this study, GPR approach was developed to detect leaks by implementing an appropriate imaging analyzing strategy based on image refinement, reflection polarity and reflection amplitude that would ease the process of interpreting the collected raw radargram image.
Abstract: The problem under research is that of unpredictable modes occurring in two-stage centrifugal hydraulic pump as a result of hydraulic processes caused by vibrations of structural components. Numerical, analytical and experimental approaches are considered. A hypothesis was developed that the problem of unpredictable pressure decrease at the second stage of centrifugal pumps is caused by cavitation effects occurring upon vibration. The problem has been studied experimentally and theoretically as of today. The theoretical study was conducted numerically and analytically. Hydroelastic processes in dynamic “liquid – deformed structure” system were numerically modelled and analysed. Using ANSYS CFX program engineering analysis complex and computing capacity of a supercomputer the cavitation parameters were established to depend on vibration parameters. An influence domain of amplitudes and vibration frequencies on concentration of cavitation bubbles was formulated. The obtained numerical solution was verified using CFM program package developed in PNRPU. The package is based on a differential equation system in hyperbolic and elliptic partial derivatives. The system is solved by using one of finite-difference method options – the particle-in-cell method. The method defines the problem solution algorithm. The obtained numerical solution was verified analytically by model problem calculations with the use of known analytical solutions of in-pipe piston movement and cantilever rod end face impact. An infrastructure consisting of an experimental fast hydro-dynamic processes research installation and a supercomputer connected by a high-speed network, was created to verify the obtained numerical solutions. Physical experiments included measurement, record, processing and analysis of data for fast processes research by using National Instrument signals measurement system and Lab View software. The model chamber end face oscillated during physical experiments and, thus, loaded the hydraulic volume. The loading frequency varied from 0 to 5 kHz. The length of the operating chamber varied from 0.4 to 1.0 m. Additional loads weighed from 2 to 10 kg. The liquid column varied from 0.4 to 1 m high. Liquid pressure history was registered. The experiment showed dependence of forced system oscillation amplitude on loading frequency at various values: operating chamber geometrical dimensions, liquid column height and structure weight. Maximum pressure oscillation (in the basic variant) amplitudes were discovered at loading frequencies of approximately 1,5 kHz. These results match the analytical and numerical solutions in ANSYS and CFM.
Abstract: To ensure the gas transmittal GCU's efficient operation, leakages through the labyrinth packings (LP) should be minimized. Leakages can be minimized by decreasing the LP gap, which in turn depends on thermal processes and possible rotor vibrations and is designed to ensure absence of mechanical contact. Vibration mitigation allows to minimize the LP gap. It is advantageous to research influence of processes in the dynamic gas-structure system on LP vibrations. This paper considers influence of rotor vibrations on LP gas dynamics and influence of the latter on the rotor structure within the FSI unidirectional dynamical coupled problem. Dependences of nonstationary parameters of gas-dynamic process in LP on rotor vibrations under various gas speeds and pressures, shaft rotation speeds and vibration amplitudes, and working medium features were studied. The programmed multi-processor ANSYS CFX was chosen as a numerical computation tool. The problem was solved using PNRPU high-capacity computer complex. Deformed shaft vibrations are replaced with an unyielding profile that moves in the fixed annulus "up-and-down" according to set harmonic rule. This solves a nonstationary gas-dynamic problem and determines time dependence of total gas-dynamic force value influencing the shaft. Pressure increase from 0.1 to 10 MPa causes growth of gas-dynamic force oscillation amplitude and frequency. The phase shift angle between gas-dynamic force oscillations and those of shaft displacement decreases from 3π/4 to π/2. Damping constant has maximum value under 1 MPa pressure in the gap. Increase of shaft oscillation frequency from 50 to 150 Hz under P=10 MPa causes growth of gas-dynamic force oscillation amplitude. Damping constant has maximum value at 50 Hz equaling 1.012. Increase of shaft vibration amplitude from 20 to 80 µm under P=10 MPa causes the rise of gas-dynamic force amplitude up to 20 times. Damping constant increases from 0.092 to 0.251. Calculations for various working substances (methane, perfect gas, air at 25 ˚С) prove the minimum gas-dynamic force persistent oscillating amplitude under P=0.1 MPa being observed in methane, and maximum in the air. Frequency remains almost unchanged and the phase shift in the air changes from 3π/4 to π/2. Calculations for various working substances (methane, perfect gas, air at 25 ˚С) prove the maximum gas-dynamic force oscillating amplitude under P=10 MPa being observed in methane, and minimum in the air. Air demonstrates surging. Increase of leakage speed from 0 to 20 m/s through LP under P=0.1 MPa causes the gas-dynamic force oscillating amplitude to decrease by 3 orders and oscillation frequency and the phase shift to increase 2 times and stabilize. Increase of leakage speed from 0 to 20 m/s in LP under P=1 MPa causes gas-dynamic force oscillating amplitude to decrease by almost 4 orders. The phase shift angle increases from π/72 to π/2. Oscillations become persistent. Flow rate proved to influence greatly on pressure oscillations amplitude and a phase shift angle. Work medium influence depends on operation conditions. At pressure growth, vibrations are mostly affected in methane (of working substances list considered), and at pressure decrease, in the air at 25 ˚С.
Abstract: At present, vibrations of rotors of gas transmittal unit evade sustainable forecasting. This paper describes elastic oscillation modes in resilient supports and rotor impellers modeled during computational experiments with regard to interference in the system of gas-dynamic flow and compressor rotor. Verification of aeroelastic approach was done on model problem of interaction between supersonic jet in shock tube with deformed plate. ANSYS 15.0 engineering analysis system was used as a modeling tool of numerical simulation in this paper. Finite volume method for gas dynamics and finite elements method for assessment of the strain stress state (SSS) components were used as research methods. Rotation speed and material’s elasticity modulus varied during calculations, and SSS components and gas-dynamic parameters in the dynamic system of gas-dynamic flow and compressor rotor were evaluated. The analysis of time dependence demonstrated that gas-dynamic parameters near the rotor blades oscillate at 200 Hz, and SSS parameters at the upper blade edge oscillate four times higher, i.e. with blade frequency. It has been detected that vibration amplitudes correction in the test points at magnetic bearings by aeroelasticity may correspond up to 50%, and about -π/4 for phases.
Abstract: This paper presents a SAC-OCDMA code with zero cross correlation property to minimize the Multiple Access Interface (MAI) as New Zero Cross Correlation code (NZCC), which is found to be more scalable compared to the other existing SAC-OCDMA codes. This NZCC code is constructed using address segment and data segment. In this work, the proposed NZCC code is implemented in an optical system using the Opti-System software for the spectral amplitude coded optical code-division multiple-access (SAC-OCDMA) scheme. The main contribution of the proposed NZCC code is the zero cross correlation, which reduces both the MAI and PIIN noises. The proposed NZCC code reveals properties of minimum cross-correlation, flexibility in selecting the code parameters and supports a large number of users, combined with high data rate and longer fiber length. Simulation results reveal that the optical code division multiple access system based on the proposed NZCC code accommodates maximum number of simultaneous users with higher data rate transmission, lower Bit Error Rates (BER) and longer travelling distance without any signal quality degradation, as compared to the former existing SAC-OCDMA codes.
Abstract: In recent years, non-invasive Focused Ultrasound (FU) has been utilized for generating bubbles (cavities) to ablate target tissue by mechanical fractionation. Intensities >10 kW/cm2 are required to generate the inertial cavities. The generation, rapid growth, and collapse of these inertial cavities cause tissue fractionation and the process is called Histotripsy. The ability to fractionate tissue from outside the body has many clinical applications including the destruction of the tumor mass. The process of tissue fractionation leaves a void at the treated site, where all the affected tissue is liquefied to particles at sub-micron size. The liquefied tissue will eventually be absorbed by the body. Histotripsy is a promising non-invasive treatment modality. This paper presents a technique for generating inertial cavities at lower intensities (< 1 kW/cm2). The technique (patent pending) is based on amplitude modulation (AM), whereby a low frequency signal modulates the amplitude of a higher frequency FU wave. Cavitation threshold is lower at low frequencies; the intensity required to generate cavitation in water at 10 kHz is two orders of magnitude lower than the intensity at 1 MHz. The Amplitude Modulation technique can operate in both continuous wave (CW) and pulse wave (PW) modes, and the percentage modulation (modulation index) can be varied from 0 % (thermal effect) to 100 % (cavitation effect), thus allowing a range of ablating effects from Hyperthermia to Histotripsy. Furthermore, changing the frequency of the modulating signal allows controlling the size of the generated cavities. Results from in vitro work demonstrate the efficacy of the new technique in fractionating soft tissue and solid calcium carbonate (Chalk) material. The technique, when combined with MR or Ultrasound imaging, will present a precise treatment modality for ablating diseased tissue without affecting the surrounding healthy tissue.
Abstract: The power generated by eight point absorber type wave energy converters each having a different buoy are calculated in order to investigate the performances of buoys in this study. The calculations are carried out by modeling three different sea states observed in two different locations in the Black Sea. The floats analyzed in this study have two basic geometries and four different draft/radius (d/r) ratios. The buoys possess the shapes of a semi-ellipsoid and a semi-elliptic paraboloid. Additionally, the draft/radius ratios range from 0.25 to 1 by an increment of 0.25. The radiation forces acting on the buoys due to the oscillatory motions of these bodies are evaluated by employing a 3D panel method along with a distribution of 3D pulsating sources in frequency domain. On the other hand, the wave forces acting on the buoys which are taken as the sum of Froude-Krylov forces and diffraction forces are calculated by using linear wave theory. Furthermore, the wave energy converters are assumed to be taut-moored to the seabed so that the secondary body which houses a power take-off system oscillates with much smaller amplitudes compared to the buoy. As a result, it is assumed that there is not any significant contribution to the power generation from the motions of the housing body and the only contribution to power generation comes from the buoy. The power take-off systems of the wave energy converters are high pressure oil hydraulic systems which are identical in terms of their characteristic parameters. The results show that the power generated by wave energy converters which have semi-ellipsoid floats is higher than that of those which have semi elliptic paraboloid floats in both locations and in all sea states. It is also determined that the power generated by the wave energy converters follow an unsteady pattern such that they do not decrease or increase with changing draft/radius ratios of the floats. Although the highest power level is obtained with a semi-ellipsoid float which has a draft/radius ratio equal to 1, other floats of which the draft/radius ratio is 0.25 delivered higher power that the floats with a draft/radius ratio equal to 1 in some cases.
Abstract: The exploitation of flow pulsation in micro- and
mini-channels is a potentially useful technique for enhancing cooling
of high-end photonics and electronics systems. It is thought that
pulsation alters the thickness of the hydrodynamic and thermal
boundary layers, and hence affects the overall thermal resistance
of the heat sink. Although the fluid mechanics and heat transfer
are inextricably linked, it can be useful to decouple the parameters
to better understand the mechanisms underlying any heat transfer
enhancement. Using two-dimensional, two-component particle image
velocimetry, the current work intends to characterize the heat transfer
mechanisms in pulsating flow with a mean Reynolds number of
48 by experimentally quantifying the hydrodynamics of a generic
liquid-cooled channel geometry. Flows circulated through the test
section by a gear pump are modulated using a controller to achieve
sinusoidal flow pulsations with Womersley numbers of 7.45 and
2.36 and an amplitude ratio of 0.75. It is found that the transient
characteristics of the measured velocity profiles are dependent on the
speed of oscillation, in accordance with the analytical solution for
flow in a rectangular channel. A large velocity overshoot is observed
close to the wall at high frequencies, resulting from the interaction
of near-wall viscous stresses and inertial effects of the main fluid
body. The steep velocity gradients at the wall are indicative of
augmented heat transfer, although the local flow reversal may reduce
the upstream temperature difference in heat transfer applications.
While unsteady effects remain evident at the lower frequency, the
annular effect subsides and retreats from the wall. The shear rate at
the wall is increased during the accelerating half-cycle and decreased
during deceleration compared to steady flow, suggesting that the flow
may experience both enhanced and diminished heat transfer during
a single period. Hence, the thickness of the hydrodynamic boundary
layer is reduced for positively moving flow during one half of the
pulsation cycle at the investigated frequencies. It is expected that the
size of the thermal boundary layer is similarly reduced during the
cycle, leading to intervals of heat transfer enhancement.
Abstract: Reinforced earth structures are generally subjected to cyclic loading generated from earthquakes. This paper presents a summary of the results and analyses of a testing program carried out in a large-scale multi-function geosynthetic testing apparatus that accommodates soil samples up to 1.0 m3. This apparatus performs different shear and pullout tests under both static and cyclic loading. The testing program was carried out to investigate the controlling factors affecting soil/geogrid interaction under cyclic loading. The extensibility of the geogrids, the applied normal stresses, the characteristics of the cyclic loading (frequency, and amplitude), and initial static load within the geogrid sheet were considered in the testing program. Based on the findings of the testing program, the effect of these parameters on the pullout resistance of geogrids, as well as the displacement mobility under cyclic loading were evaluated. Conclusions and recommendations for the design of reinforced earth walls under cyclic loading are presented.
Abstract: Ultrasonic metal welding has been the subject of ongoing research and development, most recently concentrating on metal joining in miniature devices, for example to allow solder-free wire bonding. As well as at the small scale, there are also opportunities to research the joining of thicker sheet metals and to widen the range of similar and dissimilar materials that can be successfully joined using this technology. This study presents the design, characterisation and test of a lateral-drive ultrasonic metal spot welding device. The ultrasonic metal spot welding horn is modelled using finite element analysis (FEA) and its vibration behaviour is characterised experimentally to ensure ultrasonic energy is delivered effectively to the weld coupon. The welding stack and fixtures are then designed and mounted on a test machine to allow a series of experiments to be conducted for various welding and ultrasonic parameters. Weld strength is subsequently analysed using tensile-shear tests. The results show how the weld strength is particularly sensitive to the combination of clamping force and ultrasonic vibration amplitude of the welding tip, but there are optimal combinations of these and also limits that must be clearly identified.
Abstract: Motion response of floating structures is of great
concern in marine engineering. Nonlinearity is an inherent property
of any floating bodies subjected to irregular waves. These floating
structures are continuously subjected to environmental loadings from
wave, current, wind etc. This can result in undesirable motions of the
vessel which may challenge the operability. For a floating body to
remain in its position, it should be able to induce a restoring force
when displaced. Mooring is provided to enable this restoring force.
This paper discusses the hydrodynamic performance and motion
characteristics of an 8 point spread mooring system applied to a pipe
laying barge operating in the West African sea. The modelling of the
barge is done using a computer aided-design (CAD) software
RHINOCEROS. Irregular waves are generated using a suitable wave
spectrum. Both frequency domain and time domain analysis is done.
Numerical simulations based on potential theory are carried out to
find the responses and hydrodynamic performance of the barge in
both free floating as well as moored conditions. Initially, potential
flow frequency domain analysis is done to obtain the Response
Amplitude Operator (RAO) which gives an idea about the structural
motion in free floating state. RAOs for different wave headings are
analyzed. In the following step, a time domain analysis is carried out
to obtain the responses of the structure in the moored condition. In
this study, wave induced motions are only taken into consideration.
Wind and current loads are ruled out and shall be included in further
studies. For the current study, 2000 seconds simulation is taken. The
results represent wave induced motion responses, mooring line
tensions and identify critical mooring lines.
Abstract: Journal bearings used in IC engines are prone to premature
failures and are likely to fail earlier than the rated life due to
highly impulsive and unstable operating conditions and frequent
starts/stops. Vibration signature extraction and wear debris analysis
techniques are prevalent in industry for condition monitoring of
rotary machinery. However, both techniques involve a great deal of
technical expertise, time, and cost. Limited literature is available on
the application of these techniques for fault detection in reciprocating
machinery, due to the complex nature of impact forces that
confounds the extraction of fault signals for vibration-based analysis
and wear prediction. In present study, a simulation model was developed to investigate
the bearing wear behaviour, resulting because of different operating
conditions, to complement the vibration analysis. In current
simulation, the dynamics of the engine was established first, based on
which the hydrodynamic journal bearing forces were evaluated by
numerical solution of the Reynold’s equation. In addition, the
essential outputs of interest in this study, critical to determine wear
rates are the tangential velocity and oil film thickness between the
journals and bearing sleeve, which if not maintained appropriately,
have a detrimental effect on the bearing performance. Archard’s wear prediction model was used in the simulation to
calculate the wear rate of bearings with specific location information
as all determinative parameters were obtained with reference to crank
rotation. Oil film thickness obtained from the model was used as a
criterion to determine if the lubrication is sufficient to prevent contact
between the journal and bearing thus causing accelerated wear. A
limiting value of 1 μm was used as the minimum oil film thickness
needed to prevent contact. The increased wear rate with growing
severity of operating conditions is analogous and comparable to the
rise in amplitude of the squared envelope of the referenced vibration
signals. Thus on one hand, the developed model demonstrated its
capability to explain wear behaviour and on the other hand it also
helps to establish a co-relation between wear based and vibration
based analysis. Therefore, the model provides a cost effective and
quick approach to predict the impending wear in IC engine bearings
under various operating conditions.
Abstract: Fluctuations of Schottky diode parameters in a
structure of the mixer are investigated. These fluctuations are
manifested in two ways. At the first, they lead to fluctuations in the
transfer factor that is lead to the amplitude fluctuations in the signal
of intermediate frequency. On the basis of the measurement data of
1/f noise of the diode at forward current, the estimation of a spectrum
of relative fluctuations in transfer factor of the mixer is executed.
Current dependence of the spectrum of relative fluctuations in
transfer factor of the mixer and dependence of the spectrum of
relative fluctuations in transfer factor of the mixer on the amplitude
of the heterodyne signal are investigated. At the second, fluctuations
in parameters of the diode lead to occurrence of 1/f noise in the
output signal of the mixer. This noise limits the sensitivity of the
mixer to the value of received signal.
Abstract: Brushless DC motors (BLDC) are widely used in
industrial areas. The BLDC motors are driven either by indirect ACAC
converters or by direct AC-AC converters. Direct AC-AC
converters i.e. matrix converters are used in this paper to drive the
three phase BLDC motor and it eliminates the bulky DC link energy
storage element. A matrix converter converts the AC power supply to
an AC voltage of variable amplitude and variable frequency. A
control technique is designed to generate the switching pulses for the
three phase matrix converter. For the control of speed of the BLDC
motor a separate PI controller and Fuzzy Logic Controller (FLC) are
designed and a hysteresis current controller is also designed for the
control of motor torque. The control schemes are designed and tested
separately. The simulation results of both the schemes are compared
and contrasted in this paper. The results show that the fuzzy logic
control scheme outperforms the PI control scheme in terms of
dynamic performance of the BLDC motor. Simulation results are
validated with the experimental results.
Abstract: Lateral Geniculate Nucleus (LGN) is the relay center
in the visual pathway as it receives most of the input information
from retinal ganglion cells (RGC) and sends to visual cortex. Low
threshold calcium currents (IT) at the membrane are the unique
indicator to characterize this firing functionality of the LGN neurons
gained by the RGC input. According to the LGN functional
requirements such as functional mapping of RGC to LGN, the
morphologies of the LGN neurons were developed. During the
neurological disorders like glaucoma, the mapping between RGC and
LGN is disconnected and hence stimulating LGN electrically using
deep brain electrodes can restore the functionalities of LGN. A
computational model was developed for simulating the LGN neurons
with three predominant morphologies each representing different
functional mapping of RGC to LGN. The firings of action potentials
at LGN neuron due to IT were characterized by varying the
stimulation parameters, morphological parameters and orientation. A
wide range of stimulation parameters (stimulus amplitude, duration
and frequency) represents the various strengths of the electrical
stimulation with different morphological parameters (soma size,
dendrites size and structure). The orientation (0-1800) of LGN
neuron with respect to the stimulating electrode represents the angle
at which the extracellular deep brain stimulation towards LGN
neuron is performed. A reduced dendrite structure was used in the
model using Bush–Sejnowski algorithm to decrease the
computational time while conserving its input resistance and total
surface area. The major finding is that an input potential of 0.4 V is
required to produce the action potential in the LGN neuron which is
placed at 100 μm distance from the electrode. From this study, it can
be concluded that the neuroprostheses under design would need to
consider the capability of inducing at least 0.4V to produce action
potentials in LGN.
Abstract: Introduction: Whole-Body Vibration (WBV) uses
high frequency mechanical stimuli generated by a vibration plate and
transmitted through bone, muscle and connective tissues to the whole
body. Research has shown that long-term vibration-plate training
improves neuromuscular facilitation, especially in afferent neural
pathways, responsible for the conduction of vibration and
proprioceptive stimuli, muscle function, balance and proprioception.
Some researchers suggest that the vibration stimulus briefly inhibits
the conduction of afferent signals from proprioceptors and can
interfere with the maintenance of body balance. The aim of this study
was to evaluate the influence of a single set of exercises associated
with whole-body vibration on the joint position sense and body
balance. Material and methods: The study enrolled 55 people aged
19-24 years. These individuals were randomly divided into a test
group (30 persons) and a control group (25 persons). Both groups
performed the same set of exercises on a vibration plate. The
following vibration parameters: frequency of 20Hz and amplitude of
3mm, were used in the test group. The control group performed
exercises on the vibration plate while it was off. All participants were
instructed to perform six dynamic exercises lasting 30 seconds each
with a 60-second period of rest between them. The exercises involved
large muscle groups of the trunk, pelvis and lower limbs.
Measurements were carried out before and immediately after
exercise. Joint position sense (JPS) was measured in the knee joint
for the starting position at 45° in an open kinematic chain. JPS error
was measured using a digital inclinometer. Balance was assessed in a
standing position with both feet on the ground with the eyes open and
closed (each test lasting 30 sec). Balance was assessed using Matscan
with FootMat 7.0 SAM software. The surface of the ellipse of
confidence and front-back as well as right-left swing were measured
to assess balance. Statistical analysis was performed using Statistica
10.0 PL software. Results: There were no significant differences
between the groups, both before and after the exercise (p> 0.05). JPS
did not change in both the test (10.7° vs. 8.4°) and control groups
(9.0° vs. 8.4°). No significant differences were shown in any of the
test parameters during balance tests with the eyes open or closed in
both the test and control groups (p> 0.05). Conclusions: 1.
Deterioration in proprioception or balance was not observed
immediately after the vibration stimulus. This suggests that vibrationinduced
blockage of proprioceptive stimuli conduction can have only
a short-lasting effect that occurs only as long as a vibration stimulus
is present. 2. Short-term use of vibration in treatment does not impair
proprioception and seems to be safe for patients with proprioceptive
impairment. 3. These results need to be supplemented with an
assessment of proprioception during the application of vibration
stimuli. Additionally, the impact of vibration parameters used in the
exercises should be evaluated.
Abstract: In this article, the radial displacement error correction
capability of a high precision spindle grinding caused by unbalance
force was investigated. The spindle shaft is considered as a flexible
rotor mounted on two sets of angular contact ball bearing. Finite
element methods (FEM) have been adopted for obtaining the
equation of motion of the spindle. In this paper, firstly, natural
frequencies, critical frequencies, and amplitude of the unbalance
response caused by residual unbalance are determined in order to
investigate the spindle behaviors. Furthermore, an optimization
design algorithm is employed to minimize radial displacement of the
spindle which considers dimension of the spindle shaft, the dynamic
characteristics of the bearings, critical frequencies and amplitude of
the unbalance response, and computes optimum spindle diameters
and stiffness and damping of the bearings. Numerical simulation
results show that by optimizing the spindle diameters, and stiffness
and damping in the bearings, radial displacement of the spindle can
be reduced. A spindle about 4 μm radial displacement error can be
compensated with 2 μm accuracy. This certainly can improve the
accuracy of the product of machining.