Abstract: Numerical investigation into convective heat transfer of CuO-Water based nanofluid in a pipe with return bend under laminar flow conditions has been done. The impacts of Reynolds number and the volume concentration of nanoparticles on the flow and the convective heat transfer behaviour are investigated. The results indicate that the increase in Reynolds number leads to the enhancement of average Nusselt number, and the increase in specific heat in the presence of the nanofluid results in improvement in heat transfer. Also, the presence of the secondary flow in the curve plays a key role in increasing the average Nusselt number and it appears higher than the inlet and outlet tubes. However, the pressure drop curve increases significantly in the tubes with the increase in nanoparticles concentration.
Abstract: Present study investigates the effect of unsteady wakes on heat transfer in blade tip. Heat/mass transfer was measured in blade tip region depending on a variety of strouhal number by naphthalene sublimation technique. Naphthalene sublimation technique measures heat transfer using a heat/mass transfer analogy. Experiments are performed in linear cascade which is composed of five turbine blades and rotating rods. Strouhal number of inlet flow are changed ranging from 0 to 0.22. Reynolds number is 100,000 based on 11.4 m/s of outlet flow and axial chord length. Three different squealer tip geometries such as base squealer tip, vertical rib squealer tip, and camber line squealer tip are used to study how unsteady wakes affect heat transfer on a blade tip. Depending on squealer tip geometry, different flow patterns occur on a blade tip. Also, unsteady wakes cause reduced tip leakage flow and turbulent flow. As a result, as strouhal number increases, heat/mass transfer coefficients decrease due to the reduced leakage flow. As strouhal number increases, heat/ mass transfer coefficients on a blade tip increase in vertical rib squealer tip.
Abstract: The large karstic Bell spring with a discharge ranging between 250 and 5300 lit/ sec is one of the most important springs of Kermanshah Province. This spring supplies drinking water of Nodsheh City and its surrounding villages. The spring is located in the reservoir of Daryan Dam and its mouth would be submerged after impounding under a water column of about 110 m height. This paper has aimed to render an account of the karstification pattern around the spring under consideration with the intention of preventing Bell Spring from being submerged in Daryan Dam Reservoir. The studies comprise engineering geology and hydrogeology investigations. Some geotechnical activities included in these studies include geophysical studies, drilling, excavation of exploratory gallery and shaft and diving. The results depict that Bell is a single-conduit siphon spring with 4 m diameter and 85 m height that 32 m of the conduit is located below the spring outlet. To survive the spring, it was decided to plug the outlet and convey the water to upper elevations under the natural pressure of the aquifer. After plugging, water was successfully conveyed to elevation 837 meter above sea level (about 120 m from the outlet) under the natural pressure of the aquifer. This signifies the accuracy of the studies done and proper recognition of the karstification pattern of Bell Spring. This is a unique experience in karst problems in Iran.
Abstract: Solar thermal cooling system was installed on Mechanical Research Center (MRC) Building that is located in Universitas Indonesia, Depok, Indonesia. It is the first cooling system in Indonesia that utilizes solar energy as energy input combined with natural gas; therefore, the control system must be appropriated with the climates. In order to stabilize the cooling capacity and also to maximize the use of solar energy, the system applies some controllers. Constant flow rate and on/off controller are applied for the hot water, chilled water and cooling water pumps. The hot water circulated by pump when the solar radiation is over than 400W/m2, and the chilled water is continually circulated by pump and its temperature is kept constant 7 °C by absorption chiller. The cooling water is also continually circulated until the outlet temperature of cooling tower below than 27 oC. Furthermore, the three-way valve is used to control the hot water for generate vapor on absorption chiller. The system performance using that control system is shown in this study results.
Abstract: The objective of this work was to develop a theoretical model to study the dynamic thermal behavior of a flat plate solar collector integrated with a phase change material (PCM). The PCM acted as a heat source for the solar system during low intensity solar radiation and night. The energy balance equations for the various components of the collector as well as for the PCM were formulated and numerically solved using Matlab computational program. The effect of natural convection on heat during the melting process was taken into account by using an effective thermal conductivity. The model was used to investigate the effect of inlet water temperature, water mass flow rate, and PCM thickness on the outlet water temperature and the melt fraction during charging and discharging modes. A comparison with a collector without PCM was made. Results showed that charging and discharging processes of PCM have six stages. The adding of PCM caused a decrease in temperature during charge and an increase during discharge. The rise was most enhanced for higher inlet water temperature, PCM thickness and for lower mass flow rate. Analysis indicated that the complete melting time was shorter than the solidification time due to the high heat transfer coefficient during melting. The increases in PCM height and mass flow rate were not linear with the melting and solidification times.
Abstract: Parallel Compressor Model (PCM) is a simplified approach to predict compressor performance with inlet distortions. In PCM calculation, it is assumed that the sub-compressors’ outlet static pressure is uniform and therefore simplifies PCM calculation procedure. However, if the compressor’s outlet duct is not long and straight, such assumption frequently induces error ranging from 10% to 15%. This paper provides a revised calculation method of PCM that can correct the error. The revised method employs energy equation, momentum equation and continuity equation to acquire needed parameters and replace the equal static pressure assumption. Based on the revised method, PCM is applied on two compression system with different blades types. The predictions of their performance in non-uniform inlet conditions are yielded through the revised calculation method and are employed to evaluate the method’s efficiency. Validating the results by experimental data, it is found that although little deviation occurs, calculated result agrees well with experiment data whose error ranges from 0.1% to 3%. Therefore, this proves the revised calculation method of PCM possesses great advantages in predicting the performance of the distorted compressor with limited exhaust duct.
Abstract: This research aims to develop ways of lodging
business management of Bang Khonthi community in Samut
Songkram province that are appropriate with the cultural context of
the Bang Khonthi community.
Eight lodging business owners were interviewed. It was found that
lodging business that are family business must be done with passion,
correct understanding of self, culture, nature, Thai way of life,
thorough, professional development, environmentally concerned,
building partnerships with various networks both community level,
and public sector and business cohorts. Public relations should be
done through media both traditional and modern outlets, such as
websites and social networks to provide customers convenience,
security, happiness, knowledge, love and value when travel to Bang
Khonthi. This will also help them achieve sustainability in business,
in line with the 10 Home Stay Standard Thailand.
Suggestions for operators are as follows: Operators need to
improve their public relations work. They need to use technology in
public relations such as the internet. Management standards must be
improved. Souvenir and local products shops should be arranged in
the compound. Product pricing must be set accordingly. They need to
join hands to help each other. Quality of the business operation
should be raised to meet the standards. Educational measures to
reduce the impact caused by tourism on the community such as
efforts to reduce energy consumption.
Abstract: Flash flood is occurred in short time rainfall interval:
from 1 hour to 12 hours in small and medium basins. Flash floods
typically have two characteristics: large water flow and big flow
velocity. Flash flood is occurred at hill valley site (strip of lowland of
terrain) in a catchment with large enough distribution area, steep
basin slope, and heavy rainfall. The risk of flash floods is determined
through Gridded Basin Flash Flood Potential Index (GBFFPI). Flash
Flood Potential Index (FFPI) is determined through terrain slope
flash flood index, soil erosion flash flood index, land cover flash
floods index, land use flash flood index, rainfall flash flood index.
Determining GBFFPI, each cell in a map can be considered as outlet
of a water accumulation basin. GBFFPI of the cell is determined as
basin average value of FFPI of the corresponding water accumulation
basin. Based on GIS, a tool is developed to compute GBFFPI using
ArcObjects SDK for .NET. The maps of GBFFPI are built in two
types: GBFFPI including rainfall flash flood index (real time flash
flood warning) or GBFFPI excluding rainfall flash flood index.
GBFFPI Tool can be used to determine a high flash flood potential
site in a large region as quick as possible. The GBFFPI is improved
from conventional FFPI. The advantage of GBFFPI is that GBFFPI is
taking into account the basin response (interaction of cells) and
determines more true flash flood site (strip of lowland of terrain)
while conventional FFPI is taking into account single cell and does
not consider the interaction between cells. The GBFFPI Map of
QuangNam, QuangNgai, DaNang, Hue is built and exported to
Google Earth. The obtained map proves scientific basis of GBFFPI.
Abstract: Result from the constant dwindle in natural resources,
the alternative way to reduce the costs in our daily life would be urgent
to be found in the near future. As the ancient technique based on the
theory of solar chimney since roman times, the double-skin façade are
simply composed of two large glass panels in purpose of daylighting
and also natural ventilation in the daytime. Double-skin façade is
generally installed on the exterior side of buildings as function as the
window, so there is always a huge amount of passive solar energy the
façade would receive to induce the airflow every sunny day. Therefore,
this article imposes a domestic double-skin window for residential
usage and attempts to improve the volume flow rate inside the cavity
between the panels by the frame geometry design, the installation of
outlet guide plate and the solar energy collection system. Note that the
numerical analyses are applied to investigate the characteristics of flow
field, and the boundary conditions in the simulation are totally based
on the practical experiment of the original prototype. Then we
redesign the prototype from the knowledge of the numerical results
and fluid dynamic theory, and later the experiments of modified
prototype will be conducted to verify the simulation results. The
velocities at the inlet of each case are increase by 5%, 45% and 15%
from the experimental data, and also the numerical simulation results
reported 20% improvement in volume flow rate both for the frame
geometry design and installation of outlet guide plate.
Abstract: Mineral product, waste concrete (fine aggregates),
waste in the optical field, industry, and construction employ separators
to separate solids and classify them according to their size. Various
sorting machines are used in the industrial field such as those operating
under electrical properties, centrifugal force, wind power, vibration,
and magnetic force. Study on separators has been carried out to
contribute to the environmental industry. In this study, we perform
CFD analysis for understanding the basic mechanism of the separation
of waste concrete (fine aggregate) particles from air with a machine
built with a rotor with blades. In CFD, we first performed
two-dimensional particle tracking for various particle sizes for the
model with 1 degree, 1.5 degree, and 2 degree angle between each
blade to verify the boundary conditions and the method of rotating
domain method to be used in 3D. Then we developed 3D numerical
model with ANSYS CFX to calculate the air flow and track the
particles. We judged the capability of particle separation for given size
by counting the number of particles escaping from the domain toward
the exit among 10 particles issued at the inlet. We confirm that
particles experience stagnant behavior near the exit of the rotating
blades where the centrifugal force acting on the particles is in balance
with the air drag force. It was also found that the minimum particle
size that can be separated by the machine with the rotor is determined
by its capability to stay at the outlet of the rotor channels.
Abstract: A Multi-dimensional computational fluid dynamics
(CFD) two-phase model was developed with the aim to simulate
the in-core coolant circuit of a pressurized heavy water reactor
(PHWR) of a commercial nuclear power plant (NPP). Due to the
fact that this PHWR is a Reactor Pressure Vessel type (RPV),
three-dimensional (3D) detailed modelling of the large reservoirs of
the RPV (the upper and lower plenums and the downcomer) were
coupled with an in-house finite volume one-dimensional (1D) code
in order to model the 451 coolant channels housing the nuclear fuel.
Regarding the 1D code, suitable empirical correlations for taking into
account the in-channel distributed (friction losses) and concentrated
(spacer grids, inlet and outlet throttles) pressure losses were used.
A local power distribution at each one of the coolant channels
was also taken into account. The heat transfer between the coolant
and the surrounding moderator was accurately calculated using a
two-dimensional theoretical model. The implementation of subcooled
boiling and condensation models in the 1D code along with the use
of functions for representing the thermal and dynamic properties of
the coolant and moderator (heavy water) allow to have estimations
of the in-core steam generation under nominal flow conditions for a
generic fission power distribution. The in-core mass flow distribution
results for steady state nominal conditions are in agreement with the
expected from design, thus getting a first assessment of the coupled
1/3D model. Results for nominal condition were compared with
those obtained with a previous 1/3D single-phase model getting more
realistic temperature patterns, also allowing visualize low values of
void fraction inside the upper plenum. It must be mentioned that the
current results were obtained by imposing prescribed fission power
functions from literature. Therefore, results are showed with the aim
of point out the potentiality of the developed model.
Abstract: Kurtbogazi Dam has gained special meaning for Ankara, Turkey for the last decade due to the rapid depletion of nearby resources of drinking water. In this study, the results of the analyses of Kurtbogazi Dam outlet water and the rivers flowing into the Kurtbogazi Dam were discussed for the period of last five years between 2008 and 2012. Some physical and chemical properties (pH, temperature, biochemical oxygen demand (BOD5), nitrate, phosphate and chlorine) of these water resources were evaluated. They were classified according to the Council Directive (75/440/EEC). Moreover, the properties of these surface waters were assessed to determine the quality of water for drinking and irrigation purposes using Piper, US Salinity Laboratory and Wilcox diagrams. The results showed that all the water resources are acceptable level as surface water except for Pazar Stream in terms of ortho-phosphate and BOD5 concentration for 2008.
Abstract: This study aims at improving the urban hydrological
cycle of the Orléans agglomeration (France) and understanding the
relationship between physical and chemical parameters of urban
surface runoff and the hydrological conditions. In particular water
quality parameters such as pH, conductivity, total dissolved solids,
major dissolved cations and anions, and chemical and biological
oxygen demands were monitored for three types of urban water
discharges (wastewater treatment plant output (WWTP), storm
overflow and stormwater outfall) under two hydrologic scenarios (dry
and wet weather). The first results were obtained over a period of five
months. Each investigated (Ormes, l’Egoutier and La Corne) outfall
represents an urban runoff source that receives water from runoff
roads, gutters, the irrigation of gardens and other sources of flow over
the Earth’s surface that drains in its catchments and carries it to the
Loire River. In wet weather conditions there is rain water runoff and
an additional input from the roof gutters that have entered the
stormwater system during rainfall. For the comparison the results La
Chilesse is a storm overflow that was selected in our study as a
potential source of waste water which is located before the (WWTP). The comparison of the physical-chemical parameters (total
dissolved solids, turbidity, pH, conductivity, dissolved organic
carbon (DOC), concentration of major cations and anions) together
with the chemical oxygen demand (COD) and biological oxygen
demand (BOD) helped to characterize sources of runoff waters in the
different watersheds. It also helped to highlight the infiltration of
wastewater in some stormwater systems that reject directly in the
Loire River. The values of the conductivity measured in the outflow
of Ormes were always higher than those measured in the other two
outlets. The results showed a temporal variation for the Ormes outfall
of conductivity from 1465 μS cm-1 in the dry weather flow to 650 μS
cm-1 in the wet weather flow and also a spatial variation in the wet
weather flow from 650 μS cm-1 in the Ormes outfall to 281 μS cm-1
in L’Egouttier outfall. The ultimate BOD (BOD28) showed a
significant decrease in La Corne outfall from 181 mg L-1 in the wet
weather flow to 95 mg L-1 in the dry weather flow because of the
nutrient load that was transported by the runoff.
Abstract: The comprehensive CFD models have been used to
represent and study the heterogeneous combustion of biomass. In the
present work, the operation of a global flue gas circuit in the sugarcane
bagasse combustion, from wind boxes below primary air grate
supply, passing by bagasse insertion in swirl burners and boiler
furnace, to boiler bank outlet is simulated. It uses five different
meshes representing each part of this system located in sequence:
wind boxes and grate, boiler furnace, swirl burners, superheaters and
boiler bank. The model considers turbulence using standard k-ε,
combustion using EDM, radiation heat transfer using DTM with 16
ray directions and bagasse particle tracking represented by Schiller-
Naumann model. The results showed good agreement with expected
behavior found in literature and equipment design. The more detailed
results view in separated parts of flue gas system allows observing
some flow behaviors that cannot be represented by usual
simplifications like bagasse supply under homogeneous axial and
rotational vectors and others that can be represented using new
considerations like the representation of 26 thousand grate orifices by
144 rectangular inlets.
Abstract: The separation of Hg (II) from produced water by
hollow fiber contactors (HFC) was investigation. This system
included of two hollow fiber modules in the series connecting. The
first module used for the extraction reaction and the second module
for stripping reaction. Aliquat336 extractant was fed from the organic
reservoirs into the shell side of the first hollow fiber module and
continuous to the shell side of the second module. The organic liquid
was continuously feed recirculate and back to the reservoirs. The feed
solution was pumped into the lumen (tube side) of the first hollow
fiber module. Simultaneously, the stripping solution was pumped in
the same way in tube side of the second module. The feed and
stripping solution was fed which had a countercurrent flow. Samples
were kept in the outlet of feed and stripping solution at 1 hour and
characterized concentration of Hg (II) by Inductively Couple Plasma
Atomic Emission Spectroscopy (ICP-AES). Feed solution was
produced water from natural gulf of Thailand. The extractant was
Aliquat336 dissolved in kerosene diluent. Stripping solution used was
nitric acid (HNO3) and thiourea (NH2CSNH2). The effect of carrier
concentration and type of stripping solution were investigated.
Results showed that the best condition were 10 % (v/v) Aliquat336
and 1.0 M NH2CSNH2. At the optimum condition, the extraction and
stripping of Hg (II) were 98% and 44.2%, respectively.
Abstract: In wastewater treatment processes, aeration introduces
air into a liquid. In these systems, air is introduced by different
devices submerged in the wastewater. Smaller bubbles result in more
bubble surface area per unit of volume and higher oxygen transfer
efficiency. Jet pumps are devices that use air bubbles and are widely
used in wastewater treatment processes. The principle of jet pumps is
their ability to transfer energy of one fluid, called primary or motive,
into a secondary fluid or gas. These pumps have no moving parts and
are able to work in remote areas under extreme conditions. The
objective of this work is to study experimentally the characteristics of
the jet pump and the size of air bubbles in the laboratory water tank.
The effect of flow rate ratio on pump performance is investigated in
order to have a better understanding about pump behavior under
various conditions, in order to determine the efficiency of receiving
air bubbles different sizes. The experiments show that we should take
care when increasing the flow rate ratio while seeking to decrease
bubble size in the outlet flow. This study will help improve and
extend the use of the jet pump in many practical applications.
Abstract: The thermal performance of a solar water heating with
1.00 m2 flat plate collectors in Cascavel - PR, is which presented in
this article, paper presents the solution to leverage the marketing of
solar heating systems through detailed constituent materials of the
solar collector studies, these abundant materials in construction, such
as expanded polyethylene, PVC, aluminum and glass tubes, mixing
them with new materials to minimize loss of efficiency while
decreasing its cost. The system was tested during months and the
collector obtained maximum recorded temperature of outlet fluid of
55°C, while the maximum temperature of the water at the bottom of
the hot water tank was 35°C. The average daily energy collected was
19.6 MJ/d; the energy supplied by the solar plate was 16.2 MJ/d; the
loss in the feed pipe was 3.2 MJ/d; the solar fraction was 32.2%, the
efficiency of the collector was 45.6% and the efficiency of the system
was 37.8%.
Abstract: The formulated problem of optimization of the
technological process of water treatment for thermal power plants is
considered in this article. The problem is of multiparametric nature.
To optimize the process, namely, reduce the amount of waste water, a
new technology was developed to reuse such water. A mathematical
model of the technology of wastewater reuse was developed.
Optimization parameters were determined. The model consists of a
material balance equation, an equation describing the kinetics of ion
exchange for the non-equilibrium case and an equation for the ion
exchange isotherm. The material balance equation includes a
nonlinear term that depends on the kinetics of ion exchange. A direct
problem of calculating the impurity concentration at the outlet of the
water treatment plant was numerically solved. The direct problem
was approximated by an implicit point-to-point computation
difference scheme. The inverse problem was formulated as relates to
determination of the parameters of the mathematical model of the
water treatment plant operating in non-equilibrium conditions. The
formulated inverse problem was solved. Following the results of
calculation the time of start of the filter regeneration process was
determined, as well as the period of regeneration process and the
amount of regeneration and wash water. Multi-parameter
optimization of water treatment process for thermal power plants
allowed decreasing the amount of wastewater by 15%.
Abstract: Organic Rankine Cycle (ORC) is the most commonly used method for recovering energy from small sources of heat. The investigation of the ORC in supercritical condition is a new research area as it has a potential to generate high power and thermal efficiency in a waste heat recovery system. This paper presents a steady state ORC model in supercritical condition and its simulations with a real engine’s exhaust data. The key component of ORC, evaporator, is modelled using finite volume method, modelling of all other components of the waste heat recovery system such as pump, expander and condenser are also presented. The aim of this paper is to investigate the effects of mass flow rate and evaporator outlet temperature on the efficiency of the waste heat recovery process. Additionally, the necessity of maintaining an optimum evaporator outlet temperature is also investigated. Simulation results show that modification of mass flow rate is the key to changing the operating temperature at the evaporator outlet.
Abstract: The objective of the study was to select the survival of
probiotic strains when exposed to acidic and bile salts condition. Four
probiotic strains Lactobacillus casei subsp. rhamnosus TISTR 047,
Lactobacillus casei TISTR 1500, Lactobacillus acidophilus TISTR
1338 and Lactobacillus plantarum TISTR 1465 were cultured in
MRS broth and incubated at 35ºC for 15 hours before being inoculated
into acidic condition 5 M HCl, pH 2 for 2 hours and bile salt 0.3%,
pH 5.8 for 8 hour. The survived probiotics were counted in MRS agar.
Among four stains, Lactobacillus casei subsp. rhamnosus TISTR 047
was the highest tolerance specie. Lactobacillus casei subsp.
rhamnosus TISTR 047 reduced 6.74±0.07 log CFU/ml after growing
in acid and 5.52±0.05 log CFU/ml after growing in bile salt. Then,
double emulsion of microorganisms was chosen to encapsulate before
spray drying. Spray drying was done with the inlet temperature 170ºC
and outlet temperature 80ºC. The results showed that the survival of
encapsulated Lactobacillus casei subsp. rhamnosus TISTR 047 after
spray drying decreased from 9.63 ± 0.32 to 8.31 ± 0.11 log CFU/ml
comparing with non-encapsulated, 9.63 ± 0.32 to 4.06 ± 0.08 log
CFU/ml. Therefore, Lactobacillus casei subsp. rhamnosus TISTR 047
would be able to survive in gastrointestinal and spray drying condition.