Abstract: With Power system movement toward restructuring along with factors such as life environment pollution, problems of transmission expansion and with advancement in construction technology of small generation units, it is expected that small units like wind turbines, fuel cells, photovoltaic, ... that most of the time connect to the distribution networks play a very essential role in electric power industry. With increase in developing usage of small generation units, management of distribution networks should be reviewed. The target of this paper is to present a new method for optimal management of active and reactive power in distribution networks with regard to costs pertaining to various types of dispersed generations, capacitors and cost of electric energy achieved from network. In other words, in this method it-s endeavored to select optimal sources of active and reactive power generation and controlling equipments such as dispersed generations, capacitors, under load tapchanger transformers and substations in a way that firstly costs in relation to them are minimized and secondly technical and physical constraints are regarded. Because the optimal management of distribution networks is an optimization problem with continuous and discrete variables, the new evolutionary method based on Ant Colony Algorithm has been applied. The simulation results of the method tested on two cases containing 23 and 34 buses exist and will be shown at later sections.
Abstract: This paper presents the results of a comprehensive
investigation of five blackouts that occurred on 28 August to 8
September 2011 due to bushing failures of the 132/33 kV, 125 MVA
transformers at JBB Ali Grid station. The investigation aims to
explore the root causes of the bushing failures and come up with
recommendations that help in rectifying the problem and avoiding the
reoccurrence of similar type of incidents. The incident reports about
the failed bushings and the SCADA reports at this grid station were
examined and analyzed. Moreover, comprehensive power quality
field measurements at ten 33/11 kV substations (S/Ss) in JBB Ali
area were conducted, and frequency scans were performed to verify
any harmonic resonance frequencies due to power factor correction
capacitors. Furthermore, the daily operations of the on-load tap
changers (OLTCs) of both the 125 MVA and 20 MVA transformers
at JBB Ali Grid station have been analyzed. The investigation
showed that the five bushing failures were due to a local problem, i.e.
internal degradation of the bushing insulation. This has been
confirmed by analyzing the time interval between successive OLTC
operations of the faulty grid transformers. It was also found that
monitoring the number of OLTC operations can help in predicting
bushing failure.
Abstract: This work presents a new algorithm based on a combination of fuzzy (FUZ), Dynamic Programming (DP), and Genetic Algorithm (GA) approach for capacitor allocation in distribution feeders. The problem formulation considers two distinct objectives related to total cost of power loss and total cost of capacitors including the purchase and installation costs. The novel formulation is a multi-objective and non-differentiable optimization problem. The proposed method of this article uses fuzzy reasoning for sitting of capacitors in radial distribution feeders, DP for sizing and finally GA for finding the optimum shape of membership functions which are used in fuzzy reasoning stage. The proposed method has been implemented in a software package and its effectiveness has been verified through a 9-bus radial distribution feeder for the sake of conclusions supports. A comparison has been done among the proposed method of this paper and similar methods in other research works that shows the effectiveness of the proposed method of this paper for solving optimum capacitor planning problem.
Abstract: A universal current-mode biquad is described which
represents an economical variant of well-known KHN (Kerwin,
Huelsman, Newcomb) voltage-mode filter. The circuit consists of
two multiple-output OTAs and of two grounded capacitors. Utilizing
simple splitter of the input current and a pair of jumpers, all the basic
2nd-order transfer functions can be implemented. The principle is
verified by Spice simulation on the level of a CMOS structure of
OTAs.
Abstract: The realization of current-mode quadrature oscillators
using current controlled current conveyor transconductance
amplifiers (CCCCTAs) and grounded capacitors is presented. The
proposed oscillators can provide 2 sinusoidal output currents with 90º
phase difference. It is enabled non-interactive dual-current control for
both the condition of oscillation and the frequency of oscillation.
High output impedances of the configurations enable the circuit to be
cascaded without additional current buffers. The use of only
grounded capacitors is ideal for integration. The circuit performances
are depicted through PSpice simulations, they show good agreement
to theoretical anticipation.
Abstract: This paper undertakes the problem of optimal
capacitor placement in a distribution system. The problem is how to
optimally determine the locations to install capacitors, the types and
sizes of capacitors to he installed and, during each load level,the
control settings of these capacitors in order that a desired objective
function is minimized while the load constraints,network constraints
and operational constraints (e.g. voltage profile) at different load
levels are satisfied. The problem is formulated as a combinatorial
optimization problem with a nondifferentiable objective function.
Four solution mythologies based on algorithms (GA),tabu search
(TS), and hybrid GA-SA algorithms are presented.The solution
methodologies are preceded by a sensitivity analysis to select the
candidate capacitor installation locations.
Abstract: This article presents new current-mode oscillator circuits using CDTAs which is designed from block diagram. The proposed circuits consist of two CDTAs and two grounded capacitors. The condition of oscillation and the frequency of oscillation can be adjusted by electronic method. The circuits have high output impedance and use only grounded capacitors without any external resistor which is very appropriate to future development into an integrated circuit. The results of PSPICE simulation program are corresponding to the theoretical analysis.
Abstract: In this paper the behavior of fixed series compensated
extra high voltage transmission lines during faults is simulated. Many
over-voltage protection schemes for series capacitors are limited in
terms of size and performance, and are easily affected by
environmental conditions. While the need for more compact and
environmentally robust equipment is required. use of series
capacitors for compensating part of the inductive reactance of long
transmission lines increases the power transmission capacity.
Emphasis is given on the impact of modern capacitor protection
techniques (MOV protection). The simulation study is performed
using MATLAB/SIMULINK®and results are given for a three phase
and a single phase to ground fault.
Abstract: In recent times there has been a growing interest in the
development of quasi-two-dimensional niobium pentoxide (Nb2O5)
as a semiconductor for the potential electronic applications such as
capacitors, filtration, dye-sensitised solar cells and gas sensing
platforms. Therefore once the purpose is established, Nb2O5 can be
prepared in a number of nano- and sub-micron-structural
morphologies that include rods, wires, belts and tubes. In this study
films of Nb2O5 were prepared on gold plated silicon substrate using
spin-coating technique and subsequently by mechanical exfoliation.
The reason this method was employed was to achieve layers of less
than 15nm in thickness. The sintering temperature of the specimen
was 800oC. The morphology and structural characteristics of the
films were analyzed by Atomic Force Microscopy (AFM), Raman
Spectroscopy, X-ray Photoelectron Spectroscopy (XPS).
Abstract: Today-s Voltage Regulator Modules (VRMs) face increasing design challenges as the number of transistors in microprocessors increases per Moore-s Law. These challenges have recently become even more demanding as microprocessors operate at sub voltage range at significantly high current. This paper presents a new multiphase topology with cell configuration for improved performance in low voltage and high current applications. A lab scale hardware prototype of the new topology was design and constructed. Laboratory tests were performed on the proposed converter and compared with a commercially available VRM. Results from the proposed topology exhibit improved performance compared to the commercially available counterpart.
Abstract: This article presents a current-mode quadrature
oscillator using differential different current conveyor (DDCC) and
voltage differencing transconductance amplifier (VDTA) as active
elements. The proposed circuit is realized fro m a non-inverting
lossless integrator and an inverting second order low-pass filter. The
oscillation condition and oscillation frequency can be
electronically/orthogonally controlled via input bias currents. The
circuit description is very simple, consisting of merely 1 DDCC, 1
VDTA, 1 grounded resistor and 3 grounded capacitors. Using only
grounded elements, the proposed circuit is then suitable for IC
architecture. The proposed oscillator has high output impedance
which is easy to cascade or dive the external load without the buffer
devices. The PSPICE simulation results are depicted, and the given
results agree well with the theoretical anticipation. The power
consumption is approximately 1.76mW at ±1.25V supply voltages.
Abstract: This article presents a voltage-mode universal
biquadratic filter performing simultaneous 3 standard functions: lowpass,
high-pass and band-pass functions, employing differential
different current conveyor (DDCC) and current controlled current
conveyor (CCCII) as active element. The features of the circuit are
that: the quality factor and pole frequency can be tuned independently
via the input bias currents: the circuit description is very simple,
consisting of 1 DDCC, 2 CCCIIs, 2 electronic resistors and 2
grounded capacitors. Without requiring component matching
conditions, the proposed circuit is very appropriate to further develop
into an integrated circuit. The PSPICE simulation results are
depicted. The given results agree well with the theoretical
anticipation.