Abstract: As there are also graph methods of circuit analysis in
addition to algebraic methods, it is, in theory, clearly possible to
carry out an analysis of a whole switched circuit in two-phase
switching exclusively by the graph method as well. This article deals
with two methods of full-graph solving of switched circuits: by
transformation graphs and by two-graphs. It deals with the circuit
switched capacitors and the switched current, too. All methods are
presented in an equally detailed steps to be able to compare.
Abstract: This paper presents a new and efficient approach for
capacitor placement in radial distribution systems that determine
the optimal locations and size of capacitor with an objective of
improving the voltage profile and reduction of power loss. The
solution methodology has two parts: in part one the loss sensitivity
factors are used to select the candidate locations for the capacitor
placement and in part two a new algorithm that employs Plant growth
Simulation Algorithm (PGSA) is used to estimate the optimal size
of capacitors at the optimal buses determined in part one. The main
advantage of the proposed method is that it does not require any
external control parameters. The other advantage is that it handles the
objective function and the constraints separately, avoiding the trouble
to determine the barrier factors. The proposed method is applied to 9
and 34 bus radial distribution systems. The solutions obtained by the
proposed method are compared with other methods. The proposed
method has outperformed the other methods in terms of the quality
of solution.
Abstract: A novel and efficient approach to realize
fractional-order capacitors is investigated in this paper. Meanwhile, a
new approach which is more efficient for semiconductor
implementation of fractional-order capacitors is proposed. The
feasibility of the approach has been verified with the preliminary
measured results.
Abstract: Performance of vehicle depends on driving patterns
and vehicle drive train configuration. Driving patterns depends on
traffic condition, road condition and driver behavior. HEV design is
carried out under certain constrain like vehicle operating range,
acceleration, decelerations, maximum speed and road grades which
are directly related to the driving patterns. Therefore the detailed
study on HEV performance over a different drive cycle is required
for selection and sizing of HEV components. A simple hardware is
design to measured velocity v/s time profile of the vehicle by
operating vehicle on Indian roads under real traffic conditions. To
size the HEV components, a detailed dynamic model of the vehicle is
developed considering the effect of inertia of rotating components
like wheels, drive chain, engine and electric motor. Using vehicle
model and different Indian drive cycles data, total tractive power
demanded by vehicle and power supplied by individual components
has been calculated.Using above information selection and estimation
of component sizing for HEV is carried out so that HEV performs
efficiently under hostile driving condition. Complete analysis is
carried out in LABVIEW.
Abstract: In this paper optimal capacitor placement problem has
been formulated in a restructured distribution network. In this
scenario the distribution network operator can consider reactive
energy also as a service that can be sold to transmission system. Thus
search for optimal location, size and number of capacitor banks with
the objective of loss reduction, maximum income from selling
reactive energy to transmission system and return on investment for
capacitors, has been performed. Results is influenced with economic
value of reactive energy, therefore problem has been solved for
various amounts of it. The implemented optimization technique is
genetic algorithm. For any value of reactive power economic value,
when reverse of investment index increase and change from zero or
negative values to positive values, the threshold value of selling
reactive power has been obtained. This increasing price of economic
parameter is reasonable until the network losses is less than loss
before compensation.
Abstract: Improving the reactive power and voltage profile of a
distribution substation is investigated in this paper. The purpose is to
properly determination of the shunt capacitors on/off status and
suitable tap changer (TC) position of a substation transformer. In
addition, the limitation of secondary bus voltage, the maximum
allowable number of switching operation in a day for on load tap
changer and on/off status of capacitors are taken into account. To
achieve these goals, an artificial neural network (ANN) is designed to
provide preliminary scheduling. Input of ANN is active and reactive
powers of transformer and its primary and secondary bus voltages.
The output of ANN is capacitors on/off status and TC position. The
preliminary schedule is further refined by fuzzy dynamic
programming in order to reach the final schedule. The operation of
proposed method in Q/V improving is compared with the results
obtained by operator operation in a distribution substation.
Abstract: This paper presents a new and efficient approach for capacitor placement in radial distribution systems that determine the optimal locations and size of capacitor with an objective of improving the voltage profile and reduction of power loss. The solution methodology has two parts: in part one the loss sensitivity factors are used to select the candidate locations for the capacitor placement and in part two a new algorithm that employs Plant growth Simulation Algorithm (PGSA) is used to estimate the optimal size of capacitors at the optimal buses determined in part one. The main advantage of the proposed method is that it does not require any external control parameters. The other advantage is that it handles the objective function and the constraints separately, avoiding the trouble to determine the barrier factors. The proposed method is applied to 9, 34, and 85-bus radial distribution systems. The solutions obtained by the proposed method are compared with other methods. The proposed method has outperformed the other methods in terms of the quality of solution.
Abstract: Most of the losses in a power system relate to
the distribution sector which always has been considered.
From the important factors which contribute to increase losses
in the distribution system is the existence of radioactive flows.
The most common way to compensate the radioactive power
in the system is the power to use parallel capacitors. In
addition to reducing the losses, the advantages of capacitor
placement are the reduction of the losses in the release peak of
network capacity and improving the voltage profile. The point
which should be considered in capacitor placement is the
optimal placement and specification of the amount of the
capacitor in order to maximize the advantages of capacitor
placement.
In this paper, a new technique has been offered for the
placement and the specification of the amount of the constant
capacitors in the radius distribution network on the basis of
Genetic Algorithm (GA). The existing optimal methods for
capacitor placement are mostly including those which reduce
the losses and voltage profile simultaneously. But the
retaliation cost and load changes have not been considered as
influential UN the target function .In this article, a holistic
approach has been considered for the optimal response to this
problem which includes all the parameters in the distribution
network: The price of the phase voltage and load changes. So,
a vast inquiry is required for all the possible responses. So, in
this article, we use Genetic Algorithm (GA) as the most
powerful method for optimal inquiry.
Abstract: Power Factor (PF) is one of the most important parameters in the electrical systems, especially in the water pumping station. The low power factor value of the water pumping stations causes penalty for the electrical bill. There are many methods use for power factor improvement. Each one of them uses a capacitor on the electrical power network. The position of the capacitors is varied depends on many factors such as; voltage level and capacitors rating. Adding capacitors on the motor terminals increase the supply power factor from 0.8 to more than 0.9 but these capacitors cause some problems for the electrical grid network, such as increasing the harmonic contents of the grid line voltage. In this paper the effects of using capacitors in the water pumping stations to improve the power factor value on the harmonic contents of the electrical grid network are studied. One of large water pumping stations in Kafr El-Shikh Governorate in Egypt was used, as a case study. The effect of capacitors on the line voltage harmonic contents is measured. The station uses capacitors to improve the PF values at the 1 lkv grid network. The power supply harmonics values are measured by a power quality analyzer at different loading conditions. The results showed that; the capacitors improved the power factor value of the feeder and its value increased than 0.9. But the THD values are increased by adding these capacitors. The harmonic analysis showed that; the 13th, 17th, and 19th harmonics orders are increased also by adding the capacitors.
Abstract: This paper presents an efficient algorithm for
optimization of radial distribution systems by a network
reconfiguration to balance feeder loads and eliminate overload
conditions. The system load-balancing index is used to determine the
loading conditions of the system and maximum system loading
capacity. The index value has to be minimum in the optimal network
reconfiguration of load balancing. A method based on Tabu search
algorithm, The Tabu search algorithm is employed to search for the
optimal network reconfiguration. The basic idea behind the search is
a move from a current solution to its neighborhood by effectively
utilizing a memory to provide an efficient search for optimality. It
presents low computational effort and is able to find good quality
configurations. Simulation results for a radial 69-bus system with
distributed generations and capacitors placement. The study results
show that the optimal on/off patterns of the switches can be identified
to give the best network reconfiguration involving balancing of
feeder loads while respecting all the constraints.
Abstract: With the rapid advanced of technology, the industrial processes become increasingly demanding, from the point of view, power quality and controllability. The advent of multi levels inverters responds partially to these requirements. But actually, the new generation of multi-cells inverters permits to reach more performances, since, it offers more voltage levels. The disadvantage in the increase of voltage levels by the number of cells in cascades is on account of series igbts synchronisation loss, from where, a limitation of cells in cascade to 4. Regarding to these constraints, a new topology is proposed in this paper, which increases the voltage levels of the three-cell inverter from 4 to 8; with the same number of igbts, and using less stored energy in the flaying capacitors. The details of operation and modelling of this new inverter structure are also presented, then tested thanks to a three phase induction motor. KeywordsFlaying capacitors, Multi-cells inverter, pwm, switchers, modelling.
Abstract: Scalability poses a severe threat to the existing
DRAM technology. The capacitors that are used for storing and
sensing charge in DRAM are generally not scaled beyond 42nm.
This is because; the capacitors must be sufficiently large for reliable
sensing and charge storage mechanism. This leaves DRAM memory
scaling in jeopardy, as charge sensing and storage mechanisms
become extremely difficult. In this paper we provide an overview of
the potential and the possibilities of using Phase Change Memory
(PCM) as an alternative for the existing DRAM technology. The
main challenges that we encounter in using PCM are, the limited
endurance, high access latencies, and higher dynamic energy
consumption than that of the conventional DRAM. We then provide
an overview of various methods, which can be employed to
overcome these drawbacks. Hybrid memories involving both PCM
and DRAM can be used, to achieve good tradeoffs in access latency
and storage density. We conclude by presenting, the results of these
methods that makes PCM a potential replacement for the current
DRAM technology.
Abstract: This paper present an efficient and reliable technique of optimization which combined fuel cost economic optimization and emission dispatch using the Sigmoid Decreasing Inertia Weight Particle Swarm Optimization algorithm (PSO) to reduce the cost of fuel and pollutants resulting from fuel combustion by keeping the output of generators, bus voltages, shunt capacitors and transformer tap settings within the security boundary. The performance of the proposed algorithm has been demonstrated on IEEE 30-bus system with six generating units. The results clearly show that the proposed algorithm gives better and faster speed convergence then linearly decreasing inertia weight.
Abstract: This article presents a current-mode universal biquadratic filter. The proposed circuit can apparently provide standard functions of the biquad filter: low-pass, high-pass, bandpass, band-reject and all-pass functions. The circuit uses 4 current controlled transconductance amplifiers (CCTAs) and 2 grounded capacitors. In addition, the pole frequency and quality factor can be adjusted by electronic method by adjusting the bias currents of the CCTA. The proposed circuit uses only grounded capacitors without additional external resistors, the proposed circuit is considerably appropriate to further developing into an integrated circuit. The results of PSPICE simulation program are corresponding to the theoretical analysis.
Abstract: A new current-mode multifunction filter using minimum number of passive elements is proposed. The proposed filter has single-input and four high-impedance outputs. It uses four passive elements (two capacitors and two resistors) and four dual output second generation current conveyors. Each output provides a different filter response, namely, low-pass, high-pass, band-pass and band-reject. The sensitivity analysis is also carried out on both ideal and non-ideal filter configurations. The validity of the proposed filter is verified through PSPICE simulations.
Abstract: Electrical distribution systems are incurring large losses as the loads are wide spread, inadequate reactive power compensation facilities and their improper control. A comprehensive static VAR compensator consisting of capacitor bank in five binary sequential steps in conjunction with a thyristor controlled reactor of smallest step size is employed in the investigative work. The work deals with the performance evaluation through analytical studies and practical implementation on an existing system. A fast acting error adaptive controller is developed suitable both for contactor and thyristor switched capacitors. The switching operations achieved are transient free, practically no need to provide inrush current limiting reactors, TCR size minimum providing small percentages of nontriplen harmonics, facilitates stepless variation of reactive power depending on load requirement so as maintain power factor near unity always. It is elegant, closed loop microcontroller system having the features of self regulation in adaptive mode for automatic adjustment. It is successfully tested on a distribution transformer of three phase 50 Hz, Dy11, 11KV/440V, 125 KVA capacity and the functional feasibility and technical soundness are established. The controller developed is new, adaptable to both LT & HT systems and practically established to be giving reliable performance.
Abstract: Optimal capacitor allocation in distribution systems
has been studied for a long times. It is an optimization problem
which has an objective to define the optimal sizes and locations of
capacitors to be installed. In this works, an overview of capacitor
placement problem in distribution systems is briefly introduced. The
objective functions and constraints of the problem are listed and the
methodologies for solving the problem are summarized.
Abstract: This article proposes a voltage-mode
multifunction filter using differential voltage current
controllable current conveyor transconductance amplifier
(DV-CCCCTA). The features of the circuit are that: the
quality factor and pole frequency can be tuned independently
via the values of capacitors: the circuit description is very
simple, consisting of merely 1 DV-CCCCTA, and 2
capacitors. Without any component matching conditions, the
proposed circuit is very appropriate to further develop into
an integrated circuit. Additionally, each function response
can be selected by suitably selecting input signals with
digital method. The PSpice simulation results are depicted.
The given results agree well with the theoretical anticipation.
Abstract: This paper study the segmented split capacitor
Digital-to-Analog Converter (DAC) implemented in a differentialtype
12-bit Successive Approximation Analog-to-Digital Converter
(SA-ADC). The series capacitance split array method employed as it
reduced the total area of the capacitors required for high resolution
DACs. A 12-bit regular binary array structure requires 2049 unit
capacitors (Cs) while the split array needs 127 unit Cs. These results
in the reduction of the total capacitance and power consumption of
the series split array architectures as to regular binary-weighted
structures. The paper will show the 12-bit DAC series split capacitor
with 4-bit thermometer coded DAC architectures as well as the
simulation and measured results.
Abstract: At any point of time, a power system operating
condition should be stable, meeting various operational criteria and it
should also be secure in the event of any credible contingency. Present
day power systems are being operated closer to their stability limits
due to economic and environmental constraints. Maintaining a stable
and secure operation of a power system is therefore a very important
and challenging issue. Voltage instability has been given much
attention by power system researchers and planners in recent years,
and is being regarded as one of the major sources of power system
insecurity. Voltage instability phenomena are the ones in which the
receiving end voltage decreases well below its normal value and does
not come back even after setting restoring mechanisms such as VAR
compensators, or continues to oscillate for lack of damping against the
disturbances. Reactive power limit of power system is one of the major
causes of voltage instability. This paper investigates the effects of
coordinated series capacitors (SC) with static VAR compensators
(SVC) on steady-state voltage stability of a power system. Also, the
influence of the presence of series capacitor on static VAR
compensator controller parameters and ratings required to stabilize
load voltages at certain values are highlighted.