Abstract: Owing to the lack of synchronization between the solar energy availability and the heat demands in a specific application, the energy storing sub-system is necessary to maintain the continuity of thermal process. The present work is dealing with an active solar heating storing system in which an air solar collector is connected to storing unit where this energy is distributed and provided to the heated space in a controlled manner. The solar collector is a box type absorber where the air flows between a number of vanes attached between the collector absorber and the bottom plate. This design can improve the efficiency due to increasing the heat transfer area exposed to the flowing air, as well as the heat conduction through the metal vanes from the top absorbing surface. The storing unit is a packed bed type where the air is coming from the air collector and circulated through the bed in order to add/remove the energy through the charging / discharging processes, respectively. The major advantage of the packed bed storage is its high degree of thermal stratification. Numerical solution of the packed bed energy storage is considered through dividing the bed into a number of equal segments for the bed particles and solved the energy equation for each segment depending on the neighbor ones. The studied design and performance parameters in the developed simulation model including, particle size, void fraction, etc. The final results showed that the collector efficiency was fluctuated between 55%-61% in winter season (January) under the climatic conditions of Misurata in Libya. Maximum temperature of 52ºC is attained at the top of the bed while the lower one is 25ºC at the end of the charging process of hot air into the bed. This distribution can satisfy the required load for the most house heating in Libya.
Abstract: This paper presents a detailed description of evaporative cooling systems used for space cooling in Mina Valley, Saudi Arabia. The thermal performance and environmental impact of the evaporative coolers were evaluated. It was found that the evaporative cooling systems used for space cooling in pilgrims’ accommodations and in the train stations could reduce energy consumption by as much as 75% and cut carbon dioxide emission by 78% compared to traditional vapour compression systems.
Abstract: Hybrid photovoltaic thermal (PVT) collectors allow simultaneous production of electrical energy thus heat energy. There are several configurations of hybrid collectors (to produce water or air). For hybrids water collectors, there are several configurations that differ by the nature of the absorber (serpentine, tubes...). In this paper, an absorber tank is studied. The circulation of the coolant is natural (we do not use the pump). We present the obtained results in our experimental study and we analyzed the data, and then we compare the results with the theory practices. The electrical performances of the hybrid collector are compared with those of conventional photovoltaic module mounted on the same structure and measured under the same conditions.
We conducted experiments with natural circulation of the coolant (Thermosyphon), for a flow rate of 0.025kg/m².
Abstract: The concern with sustainability brought the need for optimization of the buildings to reduce consumption of natural resources. Almost 1/3 of energy demanded by Brazilian housings is used to provide thermal solutions. AEC sector may contribute applying bioclimatic strategies on building design. The aim of this research is to investigate the viability of applying some alternative solutions in residential buildings. The research was developed with computational simulation on single family social housing, examining envelope type, absorptance, and insolation. The analysis of the thermal performance applied both Brazilian standard NBR 15575 and degree-hour method, in the scenery of Porto Alegre, a southern Brazilian city. We used BIM modeling through Revit/Autodesk and used Energy Plus to thermal simulation. The payback of the investment was calculated comparing energy savings and building costs, in a period of 50 years. The results shown that with the increment of envelope’s insulation there is thermal comfort improvement and energy economy, with a pay-back period of 24 to 36 years, in some cases.
Abstract: This study focuses on the impact of school building design factors on winter extra energy consumption which mainly includes space heating, water heating and other appliances related to winter indoor thermal conditions. A number of Auckland schools were randomly selected for the study which introduces a method of using real monthly energy consumption data for a year to calculate winter extra energy data of school buildings. The study seeks to identify the relationships between winter extra energy data related to school building design data related to the main architectural features, building envelope and elements of the sample schools. The relationships can be used to estimate the approximate saving in winter extra energy consumption which would result from a changed design datum for future school development, and identify any major energy-efficient design problems. The relationships are also valuable for developing passive design guides for school energy efficiency.
Abstract: Numerical investigation on the generality of nanoparticle velocity equation had been done on the previous published work. The three dimensional governing equations (continuity, momentum and energy) were solved using finite volume method (FVM). Parametric study of thermal performance between pure water-cooled and nanofluid-cooled are evaluated for volume fraction in the range of 1% to 4%, and nanofluid type of gamma-Al2O3 at Reynolds number range of 67.41 to 286.77. The nanofluid is modeled using single and two phase approach. Three different existing Brownian motion velocities are applied in comparing the generality of the equation for a wide parametric condition. Deviation in between the Brownian motion velocity is identified to be due to the different means of mean free path and constant value used in diffusion equation.
Abstract: In heat sinks, the flow within the core exhibits separation and hence does not lend itself to simple analytical boundary layer or duct flow analysis of the wall friction. In this paper, we present some findings from an experimental and numerical study aimed to obtain physical insight into the influence of the presence of the shield and its position on the hydraulic and thermal performance of square pin fin heat sink without top by-pass. The variations of the Nusselt number and friction factor are obtained under varied parameters, such as the Reynolds number and the shield position. The numerical code is validated by comparing the numerical results with the available experimental data. It is shown that, there is a good agreement between the temperature predictions based on the model and the experimental data. Results show that, as the presence of the shield, the heat transfer of fin array is enhanced and the flow resistance increased. The surface temperature distribution of the heat sink base is more uniform when the dimensionless shield position equals to 1/3 or 2/3. The comprehensive performance evaluation approach based on identical pumping power criteria is adopted and shows that the optimum shield position is at x/l=0.43.
Abstract: Hybrid photovoltaic thermal (PV/T) solar system comprises a solar collector which is disposed on photovoltaic solar cells. The disadvantage of a conventional photovoltaic cell is that its performance decreases as the temperature increases. Indeed, part of the solar radiation is converted into electricity and is dissipated as heat, increasing the temperature of the photovoltaic cell with respect to the ambient temperature. The objective of this work is to study experimentally and implement a hybrid prototype to evaluate electrical and thermal performance. In this paper, an experimental study of two new configurations of hybrid collectors is exposed. The results are given and interpreted. The two configurations of absorber studied are a new combination with tubes and galvanized tank, the other is a tubes and sheet.
Abstract: High voltage generators are being subject to higher
voltage rating and are being designed to operate in harsh conditions.
Stator windings are the main component of generators in which
Electrical, magnetical and thermal stresses remain major failures for
insulation degradation accelerated aging. A large number of
generators failed due to stator winding problems, mainly insulation
deterioration. Insulation degradation assessment plays vital role in the
asset life management. Mostly the stator failure is catastrophic
causing significant damage to the plant. Other than generation loss,
stator failure involves heavy repair or replacement cost. Electro
thermal analysis is the main characteristic for improvement design of
stator slot-s insulation. Dielectric parameters such as insulation
thickness, spacing, material types, geometry of winding and slot are
major design consideration. A very powerful method available to
analyze electro thermal performance is Finite Element Method
(FEM) which is used in this paper. The analysis of various stator coil
and slot configurations are used to design the better dielectric system
to reduce electrical and thermal stresses in order to increase the
power of generator in the same volume of core. This paper describes
the process used to perform classical design and improvement
analysis of stator slot-s insulation.
Abstract: For many industrial applications plate heat
exchangers are demonstrating a large superiority over the
other types of heat exchangers. The efficiency of such a
device depends on numerous factors the effect of which needs
to be analysed and accurately evaluated.
In this paper we present a theoretical analysis of a cocurrent
plate heat exchanger and the results of its numerical
simulation.
Knowing the hot and the cold fluid streams inlet temperatures,
the respective heat capacities mCp
and the value of the
overall heat transfer coefficient, a 1-D mathematical model
based on the steady flow energy balance for a differential
length of the device is developed resulting in a set of N first
order differential equations with boundary conditions where N
is the number of channels.For specific heat exchanger
geometry and operational parameters, the problem is
numerically solved using the shooting method.
The simulation allows the prediction of the temperature
map in the heat exchanger and hence, the evaluation of its
performances. A parametric analysis is performed to evaluate
the influence of the R-parameter on the e-NTU values. For
practical purposes effectiveness-NTU graphs are elaborated
for specific heat exchanger geometry and different operating
conditions.
Abstract: The experimental thermal performance of two heat
exchangers in closed-wet cooling tower (CWCT) was investigated in
this study. The test sections are heat exchangers which have multi path
that is used as the entrance of cooling water and are consisting of
bare-type copper tubes between 15.88mm and 19.05mm. The process
fluids are the cooling water that flows from top part of heat exchanger
to bottom side in the inner side of tube, and spray water that flows
gravitational direction in the outer side of it. Air contacts its outer side
of that as it counterflows. Heat and mass transfer coefficients and
cooling capacity were calculated with variations of process fluids,
multi path and different diameter tubes to figure out the performance
of characteristics of CWCT.
The main results were summarized as follows: The results show this
experiment is reliable with values of heat and mass transfer
coefficients comparing to values of correlations. Heat and mass
transfer coefficients and cooling capacity of two paths are higher than
these with one path using 15.88 and 19.05mm tubes. Cooling capacity
per unit volume with 15.88mm tube using one and two paths are
higher than 19.05mm tube due to increase of surface area per unit
volume.
Abstract: Heat pipes are two-phase heat transfer devices with
high effective thermal conductivity. Due to the high heat transport
capacity, heat exchanger with heat pipes has become much smaller
than traditional heat exchangers in handling high heat fluxes. With
the working fluid in a heat pipe, heat can be absorbed on the
evaporator region and transported to the condenser region where the
vapour condenses releasing the heat to the cooling media. Heat pipe
technology has found increasing applications in enhancing the
thermal performance of heat exchangers in microelectranics, energy
saving in HVAC systems for operating rooms,surgery centers, hotels,
cleanrooms etc, temperature regulation systems for the human body
and other industrial sectors. Development activity in heat pipe and
thermosyphon technology in asia in recent years is surveyed. Some
new results obtained in Australia and other countries are also
included.
Abstract: Auckland has a temperate climate with comfortable
warm, dry summers and mild, wet winters. An Auckland school
normally does not need air conditioning for cooling during the
summer and only need heating during the winter. The space hating
energy is the major portion of winter school energy consumption and
the winter energy consumption is major portion of annual school
energy consumption. School building thermal design should focus
on the winter thermal performance for reducing the space heating
energy. A number of Auckland schools- design data and energy
consumption data are used for this study. This pilot study
investigates the relationships between their energy consumption data
and school building design data to improve future school design for
energy efficiency.
Abstract: The use of solar control film on windows as one of
solar passive strategies for building have becoming important and is
gaining recognition. Malaysia located close to equator is having
warm humid climate with long sunshine hours and abundant solar
radiation throughout the year. Hence, befitting solar control on
windows is absolutely necessary to capture the daylight whilst
moderating thermal impact and eliminating glare problems. This is
one of the energy efficient strategies to achieve thermal and visual
comfort in buildings. Therefore, this study was carried out to
investigate the effect of window solar controls on thermal and visual
performance of naturally ventilated buildings. This was conducted via
field data monitoring using a test building facility. Four types of
window glazing systems were used with three types of solar control
films. Data were analysed for thermal and visual impact with
reference to thermal and optical characteristics of the films. Results
show that for each glazing system, the surface temperature of
windows are influenced by the Solar Energy Absorption property, the
indoor air temperature are influenced by the Solar Energy
Transmittance and Solar Energy Reflectance, and the daylighting by
Visible Light Transmission and Shading Coefficient. Further
investigations are underway to determine the mathematical relation
between thermal energy and visual performance with the thermal and
optical characteristics of solar control films.
Abstract: It is well known that surface enhancements play an important role in augmenting the thermal performance of flat plate solar collector. In this paper, an attempt is made to explain in a comparative way the effect of surface geometry of solar collector having dimple geometry with that of a flat plate solar collector of the same size. A CFD analysis was carried out for the two cases, subjected to a constant heat flux of 600W/m2 and 1000W/m2. It can be inferred from the study that the absorber plate temperature shows a rise of average surface temperature of about 50C for the dimple solar collector when compared to a flat plate solar collector. Most importantly, the average exit water temperature shows a marked improvement of about 5.50C for a dimple solar collector as compared to that of a flat plate solar collector.
Abstract: This article experimentally investigates the
thermal performance of thermoelectric air-cooling module
which comprises a thermoelectric cooler (TEC) and an
air-cooling heat sink. The influences of input current and heat
load are determined. And performances under each situation
are quantified by thermal resistance analysis. Since TEC
generates Joule heat, this nature makes construction of thermal
resistance network difficult. To simplify the analysis, this
article emphasizes on the resistance heat load might meet when
passing through the device. Therefore, the thermal resistances
in this paper are to divide temperature differences by heat load.
According to the result, there exists an optimum input current
under every heating power. In this case, the optimum input
current is around 6A or 7A. The performance of the heat sink
would be improved with TEC under certain heating power and
input current, especially at a low heat load. According to the
result, the device can even make the heat source cooler than the
ambient. However, TEC is not always effective at every heat
load and input current. In some situation, the device works
worse than the heat sink without TEC. To determine the
availability of TEC, this study figures out the effective
operating region in which the TEC air-cooling module works
better than the heat sink without TEC. The result shows that
TEC is more effective at a lower heat load. If heat load is too
high, heat sink with TEC will perform worse than without TEC.
The limit of this device is 57W. Besides, TEC is not helpful if
input current is too high or too low. There is an effective range
of input current, and the range becomes narrower when the heat
load grows.
Abstract: Conjugate natural convection in a differentially heated
square enclosure containing a polygon shaped object is studied numerically in this article. The effect of various polygon types on the
fluid flow and thermal performance of the enclosure is addressed for
different thermal conductivities. The governing equations are modeled
and solved numerically using the built-in finite element method of COMSOL software. It is found that the heat transfer rate remains
stable by varying the polygon types.
Abstract: The objectif of the present work is to determinate the
potential of the solar parabolic trough collector (PTC) for use in the
design of a solar thermal power plant in Algeria. The study is based
on a mathematical modeling of the PTC. Heat balance has been
established respectively on the heat transfer fluid (HTF), the absorber
tube and the glass envelop using the principle of energy conservation
at each surface of the HCE cross-sectionn. The modified Euler
method is used to solve the obtained differential equations. At first
the results for typical days of two seasons the thermal behavior of the
HTF, the absorber and the envelope are obtained. Then to determine
the thermal performances of the heat transfer fluid, different oils are
considered and their temperature and heat gain evolutions compared.
Abstract: Plants are commonly known for its positive
correlation in reducing temperature. Since it can benefit buildings by
modifying the microclimate, it-s also believed capable of reducing
the internal temperature. Various experiments have been done in
Universiti Sains Malaysia, Penang to investigate the comparison in
thermal benefits between two rooms, one being a typical control
room (exposed wall) and the other a biofacade room (plant shaded
wall). The investigations were conducted during non-rainy season for
approximately a month. Climbing plant Psophocarpus
tetrogonobulus from legume species was selected as insulation for
the biofacade wall. Conclusions were made on whether the biofacade
can be used to tackle the energy efficiency, based on the parameters
taken into consideration.
Abstract: This research aims at modeling and simulating the effects of nanofluids on cylindrical heat pipes thermal performance using the ANSYS-FLUENT CFD commercial software. The heat pipe outer wall temperature distribution, thermal resistance, liquid pressure and axial velocity in presence of suspended nano-scaled solid particle (i.e. Cu, Al2O3 and TiO2) within the fluid (water) were investigated. The effect of particle concentration and size were explored and it is concluded that the thermal performance of the heat pipe is improved when using nanofluid as the system working fluid. Additionally, it was observed that the thermal resistance of the heat pipe drops as the particle concentration level increases and particle radius decreases.