Abstract: Fibre-reinforced polymer (FRP) strengthened reinforced concrete (RC) structures are susceptible to intense deterioration when exposed to elevated temperatures, particularly in the incident of fire. FRP has the tendency to lose bond with the substrate due to the low glass transition temperature of epoxy; the key component of FRP matrix. In the past few decades, various types of high performance cementitious composites (HPCC) were explored for the protection of RC structural members against elevated temperature. However, there is an inadequate information on the influence of elevated temperature on the ultra high performance fibre-reinforced cementitious composites (UHPFRCC) containing ground granulated blast furnace slag (GGBS) as a replacement of high alumina cement (HAC) in conjunction with hybrid fibres (basalt and polypropylene fibres), which could be a prospective fire resisting material for the structural components. The influence of elevated temperatures on the compressive as well as flexural strength of UHPFRCC, made of HAC-GGBS and hybrid fibres, were examined in this study. Besides control sample (without fibres), three other samples, containing 0.5%, 1% and 1.5% of basalt fibres by total weight of mix and 1 kg/m3 of polypropylene fibres, were prepared and tested. Another mix was also prepared with only 1 kg/m3 of polypropylene fibres. Each of the samples were retained at ambient temperature as well as exposed to 400, 700 and 1000 °C followed by testing after 28 and 56 days of conventional curing. Investigation of results disclosed that the use of hybrid fibres significantly helped to improve the ambient temperature compressive and flexural strength of UHPFRCC, which was found to be 80 and 14.3 MPa respectively. However, the optimum residual compressive strength was marked by UHPFRCC-CP (with polypropylene fibres only), equally after both curing days (28 and 56 days), i.e. 41%. In addition, the utmost residual flexural strength, after 28 and 56 days of curing, was marked by UHPFRCC– CP and UHPFRCC– CB2 (1 kg/m3 of PP fibres + 1% of basalt fibres) i.e. 39% and 48.5% respectively.
Abstract: In this paper, a direct design using a nonlinear inelastic analysis is suggested. Also, this paper compares the load carrying capacity obtained by a nonlinear inelastic analysis with experiment results to verify the accuracy of the results. The allowable stress design results of a railroad through a plate girder bridge and the safety factor of the nonlinear inelastic analysis were compared to examine the safety performance. As a result, the load safety factor for the nonlinear inelastic analysis was twice as high as the required safety factor under the allowable stress design standard specified in the civil engineering structure design standards for urban magnetic levitation railways, which further verified the advantages of the proposed direct design method.
Abstract: This paper is a literature review presented descriptively to review the concept of green building to face the challenge of sustainable development and food in urban areas. In this paper, researchers initiated the concept of green building with sky farming method. Sky farming use vertical landscape system in order to realizing food self-sufficient green city. Sky farming relying on plantings and irrigation system efficiency in the building which is adopted the principles of green building. Planting system is done by applying hydroponic plants with Nutrient Film Technique (NFT) using energy source of solar cell and grey water from the processing of waste treatment plant. The application of sky farming in urban areas can be a recommendation for the design of environmental-friendly construction. In order to keep the land and distance efficiency, this system is a futuristic idea that would be the connector of human civilization in the future.
Abstract: The intensive use of natural aggregates, near cities and towns, associated to the increase of the global population, leads to its depletion and increases the transport distances. The uncontrolled deposition of construction and demolition waste in landfills and city outskirts, causes pollution and takes up space. The use of recycled aggregates in concrete preparation would contribute to mitigate the problem. However, it arises the problem that the high water absorption of recycled aggregate decreases the bleeding rate of concrete, and when this gets lower than the evaporation rate, plastic shrinkage cracking occurs. This phenomenon can be particularly problematic in hot and windy curing environments. Cracking facilitates the flow of liquid and gas into concrete which attacks the reinforcement and degrades the concrete. These factors reduce the durability of concrete structures and consequently the lifetime of buildings. A ring test was used, cured in a wind tunnel, to evaluate the plastic shrinkage cracking sensitivity of recycled aggregate concrete, in order to implement preventive means to control this phenomenon. The role of several aggregate properties on the concrete segregation and cracking mechanisms were also discussed.
Abstract: Seismic vulnerability assessment of masonry buildings is a fundamental issue even for moderate to low seismic hazard regions. This fact is even more important when dealing with old structures such as those located in Annaba city (Algeria), which the majority of dates back to the French colonial era from 1830. This category of buildings is in high risk due to their highly degradation state, heterogeneous materials and intrusive modifications to structural and non-structural elements. Furthermore, they are usually shelter a dense population, which is exposed to such risk. In order to undertake a suitable seismic risk mitigation strategies and reinforcement process for such structures, it is essential to estimate their seismic resistance capacity at a large scale. In this sense, two seismic vulnerability index methods and damage estimation have been adapted and applied to a pilot-scale building area located in the moderate seismic hazard region of Annaba city: The first one based on the EMS-98 building typologies, and the second one derived from the Italian GNDT approach. To perform this task, the authors took the advantage of an existing data survey previously performed for other purposes. The results obtained from the application of the two methods were integrated and compared using a geographic information system tool (GIS), with the ultimate goal of supporting the city council of Annaba for the implementation of risk mitigation and emergency planning strategies.
Abstract: The purposes of hydraulic gate are to maintain the
functions of storing and draining water. It bears long-term hydraulic
pressure and earthquake force and is very important for reservoir and
waterpower plant. The high tensile strength of steel plate is used as
constructional material of hydraulic gate. The cracks and rusts,
induced by the defects of material, bad construction and seismic
excitation and under water respectively, thus, the mechanics
phenomena of gate with crack are probing into the cause of stress
concentration, induced high crack increase rate, affect the safety and
usage of hydroelectric power plant. Stress distribution analysis is a
very important and essential surveying technique to analyze
bi-material and singular point problems. The finite difference
infinitely small element method has been demonstrated, suitable for
analyzing the buckling phenomena of welding seam and steel plate
with crack. Especially, this method can easily analyze the singularity
of kink crack. Nevertheless, the construction form and deformation
shape of some gates are three-dimensional system. Therefore, the
three-dimensional Digital Image Correlation (DIC) has been
developed and applied to analyze the strain variation of steel plate with
crack at weld joint. The proposed Digital image correlation (DIC)
technique is an only non-contact method for measuring the variation of
test object. According to rapid development of digital camera, the cost
of this digital image correlation technique has been reduced.
Otherwise, this DIC method provides with the advantages of widely
practical application of indoor test and field test without the restriction
on the size of test object. Thus, the research purpose of this research is
to develop and apply this technique to monitor mechanics crack
variations of weld steel hydraulic gate and its conformation under
action of loading. The imagines can be picked from real time
monitoring process to analyze the strain change of each loading stage.
The proposed 3-Dimensional digital image correlation method,
developed in the study, is applied to analyze the post-buckling
phenomenon and buckling tendency of welded steel plate with crack.
Then, the stress intensity of 3-dimensional analysis of different
materials and enhanced materials in steel plate has been analyzed in
this paper. The test results show that this proposed three-dimensional
DIC method can precisely detect the crack variation of welded steel
plate under different loading stages. Especially, this proposed DIC
method can detect and identify the crack position and the other flaws
of the welded steel plate that the traditional test methods hardly detect
these kind phenomena. Therefore, this proposed three-dimensional
DIC method can apply to observe the mechanics phenomena of
composite materials subjected to loading and operating.
Abstract: Cost overruns are a persistent problem in oil and gas
megaprojects. Whilst the extant literature is filled with studies on
incidents and causes of cost overruns, underlying theories to explain
their emergence in oil and gas megaprojects are few. Yet, a way to
contain the syndrome of cost overruns is to understand the bases of
‘how and why’ they occur. Such knowledge will also help to develop
pragmatic techniques for better overall management of oil and gas
megaprojects. The aim of this paper is to explain the development of
cost overruns in hydrocarbon megaprojects through the perspective of
chaos theory. The underlying principles of chaos theory and its
implications for cost overruns are examined and practical
recommendations proposed. In addition, directions for future research
in this fertile area provided.
Abstract: The ventilated façade has great advantages when
compared to traditional façades as it reduces the air conditioning
thermal loads due to the stack effect induced by solar radiation in the
air chamber. Optimizing energy consumption by using a ventilated
façade can be used not only in newly built buildings but also it can be
implemented in existing buildings, opening the field of
implementation to energy building retrofitting works. In this sense, the following three prototypes of façade where
designed, built and further analyzed in this research: non-ventilated
façade (NVF); slightly ventilated façade (SLVF) and strongly
ventilated façade (STVF). The construction characteristics of the
three facades are based on the Spanish regulation of building
construction “Technical Building Code”. The façades have been
monitored by type-k thermocouples in a representative day of the
summer season in Madrid (Spain). Moreover, an analysis of variance
(ANOVA) with repeated measures, studying the thermal lag in the
ventilated and no-ventilated façades has been designed. Results show that STVF façade presents higher levels of thermal
inertia as the thermal lag reduces up to 17% (daily mean) compared
to the non-ventilated façade. In addition, the statistical analysis
proves that an increase of the ventilation holes size in STVF façades
can improve the thermal lag significantly (p >0.05) when compared
to the SLVF façade.
Abstract: When high strength reinforced concrete is exposed to
high temperature due to a fire, deteriorations occur such as loss in
strength and elastic modulus, cracking and spalling of the concrete.
Therefore, it is important to understand risk of structural safety in
building structures by studying structural behaviors and rehabilitation
of fire damaged high strength concrete structures. This paper aims at
investigating rehabilitation effect on fire damaged high strength
concrete beams using experimental and analytical methods. In the
experiments, flexural specimens with high strength concrete are
exposed to high temperatures according to ISO 834 standard time
temperature curve. From four-point loading test, results show that
maximum loads of the rehabilitated beams are similar to or higher than
those of the non-fire damaged RC beam. In addition, structural
analyses are performed using ABAQUS 6.10-3 with same conditions
as experiments to provide accurate predictions on structural and
mechanical behaviors of rehabilitated RC beams. The parameters are
the fire cover thickness and strengths of repairing mortar. Analytical
results show good rehabilitation effects, when the results predicted
from the rehabilitated models are compared to structural behaviors of
the non-damaged RC beams. In this study, fire damaged high strength concrete beams are
rehabilitated using polymeric cement mortar. The predictions from the
finite element (FE) models show good agreements with the
experimental results and the modeling approaches can be used to
investigate applicability of various rehabilitation methods for further
study.
Abstract: It is an indispensible strategy to adopt greenery
approach on architectural bases so as to improve ecological habitats,
decrease heat-island effect, purify air quality, and relieve surface
runoff as well as noise pollution, all of which are done in an attempt to
achieve sustainable environment. How we can do with plant design to
attain the best visual quality and ideal carbon dioxide fixation depends
on whether or not we can appropriately make use of greenery
according to the nature of architectural bases. To achieve the goal, it is
a need that architects and landscape architects should be provided with
sufficient local references. Current greenery studies focus mainly on
the heat-island effect of urban with large scale. Most of the architects
still rely on people with years of expertise regarding the adoption and
disposition of plantation in connection with microclimate scale.
Therefore, environmental design, which integrates science and
aesthetics, requires fundamental research on landscape environment
technology divided from building environment technology. By doing
so, we can create mutual benefits between green building and the
environment. This issue is extremely important for the greening design
of the bases of green buildings in cities and various open spaces. The
purpose of this study is to establish plant selection and allocation
strategies under different building sunshade levels. Initially, with the
shading of sunshine on the greening bases as the starting point, the
effects of the shades produced by different building types on the
greening strategies were analyzed. Then, by measuring the PAR
(photosynthetic active radiation), the relative DLI (daily light integral)
was calculated, while the DLI Map was established in order to
evaluate the effects of the building shading on the established
environmental greening, thereby serving as a reference for plant
selection and allocation. The discussion results were to be applied in
the evaluation of environment greening of greening buildings and
establish the “right plant, right place” design strategy of multi-level
ecological greening for application in urban design and landscape
design development, as well as the greening criteria to feedback to the
eco-city greening buildings.
Abstract: This study was carried out for an underground subway station at Seoul Metro, Korea. The optimal set-points of the ventilation control system are determined every 3 hours, then, the ventilation controller adjusts the ventilation fan speed according to the optimal set-point changes. Compared to manual ventilation system which is operated irrespective of the OAQ, the IDP-based ventilation control system saves 3.7% of the energy consumption. Compared to the fixed set-point controller which is operated irrespective of the IAQ diurnal variation, the IDP-based controller shows better performance with a 2% decrease in energy consumption, maintaining the comfortable IAQ range inside the station.
Abstract: Concrete is strong in compression however weak in
tension. The tensile strength as well as ductile property of concrete
could be improved by addition of short dispersed fibers. Polyethylene
terephthalate (PET) fiber obtained from hand cutting or mechanical
slitting of plastic sheets generally used as discrete reinforcement in
substitution of steel fiber. PET fiber obtained from the former process
is in the form of straight slit sheet pattern that impart weaker
mechanical bonding behavior in the concrete matrix. To improve the
limitation of straight slit sheet fiber the present study considered two
additional geometry of fiber namely (a) flattened end slit sheet and
(b) deformed slit sheet. The mix for plain concrete was design for a
compressive strength of 25 MPa at 28 days curing time with a watercement
ratio of 0.5. Cylindrical and beam specimens with 0.5% fibers
volume fraction and without fibers were cast to investigate the
influence of geometry on the mechanical properties of concrete. The
performance parameters mainly studied include flexural strength,
splitting tensile strength, compressive strength and ultrasonic pulse
velocity (UPV). Test results show that geometry of fiber has a
marginal effect on the workability of concrete. However, it plays a
significant role in achieving a good compressive and tensile strength
of concrete. Further, significant improvement in term of flexural and
energy dissipation capacity were observed from other fibers as
compared to the straight slit sheet pattern. Also, the inclusion of PET
fiber improved the ability in absorbing energy in the post-cracking
state of the specimen as well as no significant porous structures.
Abstract: Sewer deposits have been identified as a major cause
of dysfunctions in combined sewer systems regarding sewer
management, which induces different negative consequents resulting
in poor hydraulic conveyance, environmental damages as well as
worker’s health. In order to overcome the problematics of
sedimentation, flushing has been considered as the most operative
and cost-effective way to minimize the sediments impacts and
prevent such challenges. Flushing, by prompting turbulent wave
effects, can modify the bed form depending on the hydraulic
properties and geometrical characteristics of the conduit. So far, the
dynamics of the bed-load during high-flow events in combined sewer
systems as a complex environment is not well understood, mostly due
to lack of measuring devices capable to work in the “hostile” in
combined sewer system correctly. In this regards, a one-episode
flushing issue from an opening gate valve with weir function was
carried out in a trunk sewer in Paris to understand its cleansing
efficiency on the sediments (thickness: 0-30 cm). During more than
1h of flushing within 5 m distance in downstream of this flushing
device, a maximum flowrate and a maximum level of water have
been recorded at 5 m in downstream of the gate as 4.1 m3/s and 2.1
m respectively. This paper is aimed to evaluate the efficiency of this
type of gate for around 1.1 km (from the point -50 m to +1050 m in
downstream from the gate) by (i) determining bed grain-size
distribution and sediments evolution through the sewer channel, as
well as their organic matter content, and (ii) identifying sections that
exhibit more changes in their texture after the flush. For the first one,
two series of sampling were taken from the sewer length and then
analyzed in laboratory, one before flushing and second after, at same
points among the sewer channel. Hence, a non-intrusive sampling
instrument has undertaken to extract the sediments smaller than the
fine gravels. The comparison between sediments texture after the
flush operation and the initial state, revealed the most modified zones
by the flush effect, regarding the sewer invert slope and hydraulic
parameters in the zone up to 400 m from the gate. At this distance,
despite the increase of sediment grain-size rages, D50 (median grainsize)
varies between 0.6 mm and 1.1 mm compared to 0.8 mm and 10
mm before and after flushing, respectively. Overall, regarding the
sewer channel invert slope, results indicate that grains smaller than
sands (< 2 mm) are more transported to downstream along about 400
m from the gate: in average 69% before against 38% after the flush
with more dispersion of grain-sizes distributions. Furthermore, high
effect of the channel bed irregularities on the bed material evolution
has been observed after the flush.
Abstract: The objective of this paper is to evaluate the effects of
soil-structure interaction (SSI) on the modal characteristics and on
the dynamic response of current structures. The objective is on the
overall behaviour of a real structure of five storeys reinforced
concrete (R/C) building typically encountered in Algeria. Sensitivity
studies are undertaken in order to study the effects of frequency
content of the input motion, frequency of the soil-structure system,
rigidity and depth of the soil layer on the dynamic response of such
structures. This investigation indicated that the rigidity of the soil
layer is the predominant factor in soil-structure interaction and its
increases would definitely reduce the deformation in the R/C
structure. On the other hand, increasing the period of the underlying
soil will cause an increase in the lateral displacements at story levels
and create irregularity in the distribution of story shears. Possible
resonance between the frequency content of the input motion and soil
could also play an important role in increasing the structural
response.
Abstract: In recent years, fire accidents have been steadily
increased and the amount of property damage caused by the accidents
has gradually raised. Damaging building structure, fire incidents bring
about not only such property damage but also strength degradation and
member deformation. As a result, the building structure undermines its
structural ability. Examining the degradation and the deformation is
very important because reusing the building is more economical than
reconstruction. Therefore, engineers need to investigate the strength
degradation and member deformation well, and make sure that they
apply right rehabilitation methods. This study aims at evaluating
deformation characteristics of fire damaged and rehabilitated normal
strength concrete beams through both experiments and finite element
analyses. For the experiments, control beams, fire damaged beams and
rehabilitated beams are tested to examine deformation characteristics.
Ten test beam specimens with compressive strength of 21MPa are
fabricated and main test variables are selected as cover thickness of
40mm and 50mm and fire exposure time of 1 hour or 2 hours. After
heating, fire damaged beams are air-recurred for 2 months and
rehabilitated beams are repaired with polymeric cement mortar after
being removed the fire damaged concrete cover. All beam specimens
are tested under four points loading. FE analyses are executed to
investigate the effects of main parameters applied to experimental
study. Test results show that both maximum load and stiffness of the
rehabilitated beams are higher than those of the fire damaged beams.
In addition, predicted structural behaviors from the analyses also show
good rehabilitation effect and the predicted load-deflection curves are
similar to the experimental results. For the further, the proposed
analytical method can be used to predict deformation characteristics of
fire damaged and rehabilitated concrete beams without suffering from
time and cost consuming of experimental process.
Abstract: Single angle connections, which are bolted to the beam
web and the column flange, are studied to investigate their
moment-rotation behavior. Elastic–perfectly plastic material behavior
is assumed. ABAQUS software is used to analyze the nonlinear
behavior of a single angle connection. The identical geometric and
material conditions with Lipson’s test are used for verifying finite
element models. Since Kishi and Chen’s Power model and Lee and
Moon’s Log model are accurate only for a limited range of mechanism,
simpler and more accurate hyperbolic function models are proposed.
Abstract: This study suggests the estimation method of stress
distribution for the beam structures based on TLS (Terrestrial Laser
Scanning). The main components of method are the creation of the
lattices of raw data from TLS to satisfy the suitable condition and
application of CSSI (Cubic Smoothing Spline Interpolation) for
estimating stress distribution. Estimation of stress distribution for the
structural member or the whole structure is one of the important
factors for safety evaluation of the structure. Existing sensors which
include ESG (Electric strain gauge) and LVDT (Linear Variable
Differential Transformer) can be categorized as contact type sensor
which should be installed on the structural members and also there are
various limitations such as the need of separate space where the
network cables are installed and the difficulty of access for sensor
installation in real buildings. To overcome these problems inherent in
the contact type sensors, TLS system of LiDAR (light detection and
ranging), which can measure the displacement of a target in a long
range without the influence of surrounding environment and also get
the whole shape of the structure, has been applied to the field of
structural health monitoring. The important characteristic of TLS
measuring is a formation of point clouds which has many points
including the local coordinate. Point clouds are not linear distribution
but dispersed shape. Thus, to analyze point clouds, the interpolation is
needed vitally. Through formation of averaged lattices and CSSI for
the raw data, the method which can estimate the displacement of
simple beam was developed. Also, the developed method can be
extended to calculate the strain and finally applicable to estimate a
stress distribution of a structural member. To verify the validity of the
method, the loading test on a simple beam was conducted and TLS
measured it. Through a comparison of the estimated stress and
reference stress, the validity of the method is confirmed.
Abstract: The paper provides a comprehensive analysis of the
sustainable development in the Belgrade Metropolitan Region - BMA
(level NUTS 2) preliminary evaluating the three chosen components:
1) economic growth and developmental changes; 2) competitiveness;
and 3) territorial concentration and industrial specialization. First, we
identified the main results of development changes and economic
growth by applying Shift-share analysis on the metropolitan level.
Second, the empirical evaluation of competitiveness in the BMA is
based on the analysis of absolute and relative values of eight
indicators by Spider method. Paper shows that the consideration of
the national share, industrial mix and metropolitan/regional share in
total Shift share of the BMA, as well as economic/functional
specialization of the BMA indicate very strong process of
deindustrialization. Allocative component of the BMA economic
growth has positive value, reflecting the above-average sector
productivity compared to the national average. Third, the important
positive role of metropolitan/regional component in decomposition of
the BMA economic growth is highlighted as one of the key results.
Finally, comparative analysis of the industrial territorial
concentration in the BMA in relation to Serbia is based on location
quotient (LQ) or Balassa index as a valid measure. The results
indicate absolute and relative differences in decrease of industry
territorial concentration as well as inefficiency of utilizing territorial
capital in the BMA. Results are important for the increase of regional
competitiveness and territorial distribution in this area as well as for
improvement of sustainable metropolitan and sector policies,
planning and governance on this level.
Abstract: In this study, the feasibility of incorporating ceramic
waste from bricks (perforated brick and double hollow brick) and
extruded polystyrene (XPS) waste, is analysed.
Results show that it is possible to incorporate up to 25% of
ceramic waste and 4% of XPS waste over the weight of gypsum in a
gypsum matrix. Furthermore, with the addition of ceramic waste an
8% of surface hardness increase and a 25% of capillary water
absorption reduction can be obtained. On the other hand, with the
addition of XPS, a 26% reduction of density and a 37% improvement
of thermal conductivity can be obtained.
The obtained results are favorable to use these materials in order to
produce prefabricated gypsum and also as material for interior
cladding walls.
Abstract: The present study is concerned with the problem of determining the shape of the free surface flow in a hydraulic channel which has an uneven bottom. For the mathematical formulation of the problem, the fluid of the two-dimensional irrotational steady flow in water is assumed inviscid and incompressible. The solutions of the nonlinear problem are obtained by using the usual conformal mapping theory and Hilbert’s technique. An experimental study, for comparing the obtained results, has been conducted in a hydraulic channel (subcritical regime and supercritical regime).