Abstract: Various retrofit techniques for reinforced concrete frame with infill wall have been steadily developed. Among those techniques, strengthening methodology based on diagonal FRP strips (FRP bracings) has numerous advantages such as feasibility of implementing without interrupting the building under operation, reduction of cost and time, and easy application. Considering the safety of structure and retrofit cost, the most appropriate retrofit solution is needed. Thus, the objective of this study is to suggest pareto-optimal solution for existing building using FRP bracings. To find pareto-optimal solution analysis, NSGA-II is applied. Moreover, the seismic performance of retrofit building is evaluated. The example building is 5-storey, 3-bay RC frames with infill wall. Nonlinear static pushover analyses are performed with FEMA 356. The criterion of performance evaluation is inter-story drift ratio at the performance level IO, LS, CP. Optimal retrofit solutions is obtained for 32 individuals and 200 generations. Through the proposed optimal solutions, we confirm the improvement of seismic performance of the example building.
Abstract: This study suggests the estimation method of stress
distribution for the beam structures based on TLS (Terrestrial Laser
Scanning). The main components of method are the creation of the
lattices of raw data from TLS to satisfy the suitable condition and
application of CSSI (Cubic Smoothing Spline Interpolation) for
estimating stress distribution. Estimation of stress distribution for the
structural member or the whole structure is one of the important
factors for safety evaluation of the structure. Existing sensors which
include ESG (Electric strain gauge) and LVDT (Linear Variable
Differential Transformer) can be categorized as contact type sensor
which should be installed on the structural members and also there are
various limitations such as the need of separate space where the
network cables are installed and the difficulty of access for sensor
installation in real buildings. To overcome these problems inherent in
the contact type sensors, TLS system of LiDAR (light detection and
ranging), which can measure the displacement of a target in a long
range without the influence of surrounding environment and also get
the whole shape of the structure, has been applied to the field of
structural health monitoring. The important characteristic of TLS
measuring is a formation of point clouds which has many points
including the local coordinate. Point clouds are not linear distribution
but dispersed shape. Thus, to analyze point clouds, the interpolation is
needed vitally. Through formation of averaged lattices and CSSI for
the raw data, the method which can estimate the displacement of
simple beam was developed. Also, the developed method can be
extended to calculate the strain and finally applicable to estimate a
stress distribution of a structural member. To verify the validity of the
method, the loading test on a simple beam was conducted and TLS
measured it. Through a comparison of the estimated stress and
reference stress, the validity of the method is confirmed.