Abstract: In this research, the TRACE/PARCS model of
Lungmen ABWR has been developed for verification of ultimate
response guideline (URG) efficiency. This ultimate measure was
named as DIVing plan, abbreviated from system depressurization,
water injection and containment venting. The simulation initial
condition is 100% rated power/100% rated core flow. This research
focuses on the estimation of the time when the fuel might be damaged
with no water injection by using TRACE/PARCS first. Then, the
effect of the reactor core isolation system (RCIC), control
depressurization and ac-independent water addition system (ACIWA),
which can provide the injection with 950 gpm are also estimated for
the station blackout (SBO) transient.
Abstract: Fuel rod analysis program transient (FRAPTRAN)
code was used to study the fuel rod performance during a postulated
large break loss of coolant accident (LBLOCA) in Maanshan nuclear
power plant (NPP). Previous transient results from thermal hydraulic
code, TRACE, with the same LBLOCA scenario, were used as input
boundary conditions for FRAPTRAN. The simulation results showed
that the peak cladding temperatures and the fuel centerline
temperatures were all below the 10CFR50.46 LOCA criteria. In
addition, the maximum hoop stress was 18 MPa and the oxide
thickness was 0.003mm for the present simulation cases, which are all
within the safety operation ranges. The present study confirms that this
analysis method, the FRAPTRAN code combined with TRACE, is an
appropriate approach to predict the fuel integrity under LBLOCA with
operational ECCS.
Abstract: This analysis of Kuosheng nuclear power plant (NPP)
was performed mainly by TRACE, assisted with FRAPTRAN and
FRAPCON. SNAP v2.2.1 and TRACE v5.0p3 are used to develop the
Kuosheng NPP SPU TRACE model which can simulate the turbine
trip without bypass transient. From the analysis of TRACE, the
important parameters such as dome pressure, coolant temperature and
pressure can be determined. Through these parameters, comparing
with the criteria which were formulated by United States Nuclear
Regulatory Commission (U.S. NRC), we can determine whether the
Kuoshengnuclear power plant failed or not in the accident analysis.
However, from the data of TRACE, the fuel rods status cannot be
determined. With the information from TRACE and burn-up analysis
obtained from FRAPCON, FRAPTRAN analyzes more details about
the fuel rods in this transient. Besides, through the SNAP interface, the
data results can be presented as an animation. From the animation, the
TRACE and FRAPTRAN data can be merged together that may be
realized by the readers more easily. In this research, TRACE showed
that the maximum dome pressure of the reactor reaches to 8.32 MPa,
which is lower than the acceptance limit 9.58 MPa. Furthermore,
FRAPTRAN revels that the maximum strain is about 0.00165, which
is below the criteria 0.01. In addition, cladding enthalpy is 52.44 cal/g
which is lower than 170 cal/g specified by the USNRC NUREG-0800
Standard Review Plan.