Abstract: In this study, the RASCAL and ALOHA codes are used to establish an analysis methodology for hydrogen fluoride (HF) evaluation. There are three main steps in this study. First, the UF6 data were collected. Second, one postulated case was analyzed by using the RASCAL and UF6 data. This postulated case assumes that fire occurring and UF6 is releasing from a building. Third, the results of RASCAL for HF mass were as the input data of ALOHA. Two postulated cases of HF were analyzed by using ALOHA code and the results of RASCAL. These postulated cases assume fire occurring and HF is releasing with no raining (Case 1) or raining (Case 2) condition. According to the analysis results of ALOHA, the HF concentration of Case 2 is smaller than Case 1. The results can be a reference for the preparing of emergency plans for the release of HF.
Abstract: Not only radiation materials, but also the normal chemical material stored in the power plant can cause a risk to the residents. In this research, the ALOHA code was used to perform the concentration analysis under the CO2 storage burst or leakage conditions for Kuosheng nuclear power plant (NPP). The Final Safety Analysis Report (FSAR) and data were used in this study. Additionally, the analysis results of ALOHA code were compared with the R.G. 1.78 failure criteria in order to confirm the control room habitability. The comparison results show that the ALOHA result for burst case was 0.923 g/m3 which was below the criteria. However, the ALOHA results for leakage case was 11.3 g/m3.
Abstract: In this study, we focus on the establishment of the analysis model for Maanshan PWR nuclear power plant (NPP) by using RADTRAD and SNAP codes with the FSAR, manuals, and other data. In order to evaluate the cumulative dose at the Exclusion Area Boundary (EAB) and Low Population Zone (LPZ) outer boundary, Maanshan NPP RADTRAD/SNAP model was used to perform the analysis of the DBA LOCA case. The analysis results of RADTRAD were similar to FSAR data. These analysis results were lower than the failure criteria of 10 CFR 100.11 (a total radiation dose to the whole body, 250 mSv; a total radiation dose to the thyroid from iodine exposure, 3000 mSv).
Abstract: In this study of ultimate response guideline (URG), Kuosheng BWR/6 nuclear power plant (NPP) TRACE model was established. The reactor depressurization, low pressure water injection, and containment venting are the main actions of URG. This research focuses to evaluate the efficiency of URG under Fukushima-like conditions. Additionally, the sensitivity study of URG was also performed in this research. The analysis results of TRACE present that URG can keep the peak cladding temperature (PCT) below 1088.7 K (the failure criteria) under Fukushima-like conditions. It implied that Kuosheng NPP was at the safe situation.
Abstract: TRACE is developed by U.S. NRC for the nuclear
power plants (NPPs) safety analysis. We focus on the establishment
and application of TRACE/FRAPTRAN/SNAP models for Chinshan
NPP (BWR/4) spent fuel pool in this research. The geometry is 12.17
m × 7.87 m × 11.61 m for the spent fuel pool. In this study, there are
three TRACE/SNAP models: one-channel, two-channel, and
multi-channel TRACE/SNAP model. Additionally, the cooling system
failure of the spent fuel pool was simulated and analyzed by using the
above models. According to the analysis results, the peak cladding
temperature response was more accurate in the multi-channel
TRACE/SNAP model. The results depicted that the uncovered of the
fuels occurred at 2.7 day after the cooling system failed. In order to
estimate the detailed fuel rods performance, FRAPTRAN code was
used in this research. According to the results of FRAPTRAN, the
highest cladding temperature located on the node 21 of the fuel rod
(the highest node at node 23) and the cladding burst roughly after 3.7
day.
Abstract: In this research, TRACE model of Chinshan BWR/4
nuclear power plant (NPP) has been developed for the simulation and
analysis of ultimate response guideline (URG).The main actions of
URG are the depressurization and low pressure water injection of
reactor and containment venting. This research focuses to verify the
URG efficiency under Fukushima-like conditions. TRACE analysis
results show that the URG can keep the PCT below the criteria
1088.7 K under Fukushima-like conditions. It indicated that Chinshan
NPP was safe.
Abstract: The dry-storage systems of nuclear power plants (NPPs) in Taiwan have become one of the major safety concerns. There are two steps considered in this study. The first step is the verification of the TRACE by using VSC-17 experimental data. The results of TRACE were similar to the VSC-17 data. It indicates that TRACE has the respectable accuracy in the simulation and analysis of the dry-storage systems. The next step is the application of TRACE in the dry-storage system of Kuosheng NPP (BWR/6). Kuosheng NPP is the second BWR NPP of Taiwan Power Company. In order to solve the storage of the spent fuels, Taiwan Power Company developed the new dry-storage system for Kuosheng NPP. In this step, the dry-storage system model of Kuosheng NPP was established by TRACE. Then, the steady state simulation of this model was performed and the results of TRACE were compared with the Kuosheng NPP data. Finally, this model was used to perform the safety analysis of Kuosheng NPP dry-storage system. Besides, FRAPTRAN was used tocalculate the transient performance of fuel rods.