The Study of Ultimate Response Guideline of Kuosheng BWR/6 Nuclear Power Plant Using TRACE and SNAP

In this study of ultimate response guideline (URG), Kuosheng BWR/6 nuclear power plant (NPP) TRACE model was established. The reactor depressurization, low pressure water injection, and containment venting are the main actions of URG. This research focuses to evaluate the efficiency of URG under Fukushima-like conditions. Additionally, the sensitivity study of URG was also performed in this research. The analysis results of TRACE present that URG can keep the peak cladding temperature (PCT) below 1088.7 K (the failure criteria) under Fukushima-like conditions. It implied that Kuosheng NPP was at the safe situation.




References:
[1] K.S. Liang, S.C. Chiang, Y.F. Hsu, H.J. Young, B.S. Pei, L.C. Wang, “The ultimate emergency measures to secure a NPP under an accidental condition with no designed power or water supply,” Nuclear Engineering and Design, 253, pp.259-268, 2012.
[2] Taiwan Power Company, “Kuosheng nuclear power plant ultimate response guideline”, No. 1451, 2012.
[3] U.S. NRC, “TRACE V5.0 User’s Manual”, 2010.
[4] J. R. Wang et al, “Kuosheng Startup Tests Transient Analyses, INER report”, INER-0965, 1989.
[5] Taiwan Power Company, “Final Safety Analysis Report for Kuosheng Nuclear Power Station Units 1&2”, 2001.