Abstract: There exist significant losses on transmission lines due to distance, as power generating stations could be located far from some isolated settlements. Standalone wind farms could be a good choice of alternative power generation for such settlements that are far from the grid due to factors of long distance or socio-economic problems. However, uncompensated wind farms consume reactive power since wind turbines are induction generators. Therefore, capacitor banks are used to compensate reactive power, which in turn improves the voltage profile of the network. Although capacitor banks help improving voltage profile, they also undergo switching actions due to its compensating response to the variation of various types of load at the consumer’s end. These switching activities could cause transient overvoltage on the network, jeopardizing the end-life of other equipment on the system. In this paper, the overvoltage caused by these switching activities is investigated using the IEEE bus 14-network to represent a standalone wind farm, and the simulation is done using ATP/EMTP software. Scenarios involving the use of pre-insertion resistor and pre-insertion inductor, as well as controlled switching was also carried out in order to decide the best mitigation option to reduce the overvoltage.
Abstract: This paper treats a design of combined control of a
single phase power factor correction (PFC). The strategy of the
proposed control is based on two parts, the first, for the outer loop
(DC output regulated voltage), and the second govern the input
current of the converter in order to achieve a sinusoidal form in phase
with the grid voltage. Two kinds of regulators are used, Fuzzy
controller for the outer loop and predictive controller for the inner
loop. The controllers are verified and discussed through simulation
under MATLAB/Simulink platform. Also an experimental
confirmation is applied. Results present a high dynamic performance
under various parameters changes.
Abstract: The Flexible AC Transmission System (FACTS)
technology is a new advanced solution that increases the reliability
and provides more flexibility, controllability, and stability of a power
system. The Unified Power Flow Controller (UPFC), as the most
versatile FACTS device for regulating power flow, is able to control
respectively transmission line real power, reactive power, and node
voltage. The main purpose of this paper is to analyze the effect of the
UPFC on the load flow, the power losses, and the voltage stability
using NEPLAN software modules, Newton-Raphson load flow is
used for the power flow analysis and the modal analysis is used for
the study of the voltage stability. The simulation was carried out on
the IEEE 14-bus test system.
Abstract: This paper aims to analysis the behavior of DC corona
discharge in wire-to-plate electrostatic precipitators (ESP). Currentvoltage
curves are particularly analyzed. Experimental results show
that discharge current is strongly affected by the applied voltage. The proposed method of current identification is to use the method
of least squares. Least squares problems that of into two categories:
linear or ordinary least squares and non-linear least squares,
depending on whether or not the residuals are linear in all unknowns.
The linear least-squares problem occurs in statistical regression
analysis; it has a closed-form solution. A closed-form solution (or
closed form expression) is any formula that can be evaluated in a
finite number of standard operations. The non-linear problem has no
closed-form solution and is usually solved by iterative.
Abstract: Hydrogen produced by means of polymer electrolyte
membrane electrolyzer (PEME) is one of the most promising
methods due to clean and renewable energy source. In the process,
some energy loss due to mass transfer through a PEM is caused by
diffusion, electro-osmotic drag, and the pressure difference between
the cathode channel and anode channel. In PEME, water molecules
and ionic particles transferred between the electrodes from anode to
cathode, Extensive mixing of the hydrogen and oxygen at anode
channel due to gases cross-over must be avoided. In recent times the
consciousness of safety issue in high pressure PEME where the
oxygen mix with hydrogen at anode channel could create, explosive
conditions have generated a lot of concern. In this paper, the steady
state and simulation analysis of gases crossover in PEME on the
temperature and pressure effect are presented. The simulations have
been analysis in MATLAB based on the well-known Fick’s Law of
molecular diffusion. The simulation results indicated that as
temperature increases, there is a significant decrease in operating
voltage.
Abstract: These days, the industrial trend is moving away from heavy and bulky passive components to power converter systems that use more and more semiconductor elements. Also, it is difficult to connect the traditional converters to the high and medium voltage. For these reasons, a new family of multilevel inverters has appeared as a solution for working with higher voltage levels. Different modulation topologies like Sinusoidal Pulse Width Modulation (SPWM), Selective Harmonic Elimination Pulse Width Modulation (SHE-PWM) are available for multilevel inverters. In this work, different hybrid modulation techniques which are combination of fundamental frequency modulation and multilevel sinusoidal-modulation are compared. The main characteristic of these modulations are reduction of switching losses with good harmonic performance and balanced power loss dissipation among the device. The proposed hybrid modulation schemes are developed and simulated in Matlab/Simulink for cascaded H-bridge inverter. The results validate the applicability of the proposed schemes for cascaded multilevel inverter.
Abstract: This paper introduces a boost converter with a new
active snubber cell. In this circuit, all of the semiconductor
components in the converter softly turns on and turns off with the
help of the active snubber cell. Compared to the other converters, the
proposed converter has advantages of size, number of components
and cost. The main feature of proposed converter is that the extra
voltage stresses do not occur on the main switches and main diodes.
Also, the current stress on the main switch is acceptable level.
Moreover, the proposed converter can operates under light load
conditions and wide input line voltage. In this study, the operating
principle of the proposed converter is presented and its operation is
verified with the Proteus simulation software for a 1 kW and 100 kHz
model.
Abstract: In this paper, influence of harmonics on medium
voltage distribution system of Bogazici Electricity Distribution Inc.
(BEDAS) which takes place at Istanbul/Turkey is investigated. A ring
network consisting of residential loads is taken into account for this
study. Real system parameters and measurement results are used for
simulations. Also, probable working conditions of the system are
analyzed for 50%, 75%, and 100% loading of transformers with
similar harmonic contents. Results of the study are exhibited the
influence of nonlinear loads on %THDV, P.F. and technical losses of
the medium voltage distribution system.
Abstract: Among various active filters, shunt active filter is a
viable solution for reactive power and harmonics compensation. In
this paper, the SRF plan is used to generate current reference for
compensation and conventional PI controllers were used as the
controller to compensate the reactive power. The design of the closed
loop controllers is reserved simple by modeling them as first order
systems. Computationally uncomplicated and efficient SVM system
is used in the present work for better utilization of dc bus voltage.
The rating of shunt active filter has been finalized based on the
reactive power demand of the selected reactive load. The proposed
control and SVM technique are validated by simulating in MATLAB
software.
Abstract: This research paper presents highly optimized barrel
shifter at 22nm Hi K metal gate strained Si technology node. This
barrel shifter is having a unique combination of static and dynamic
body bias which gives lowest power delay product. This power delay
product is compared with the same circuit at same technology node
with static forward biasing at ‘supply/2’ and also with normal reverse
substrate biasing and still found to be the lowest. The power delay
product of this barrel sifter is .39362X10-17J and is lowered by
approximately 78% to reference proposed barrel shifter at 32nm bulk
CMOS technology. Power delay product of barrel shifter at 22nm Hi
K Metal gate technology with normal reverse substrate bias is
2.97186933X10-17J and can be compared with this design’s PDP of
.39362X10-17J. This design uses both static and dynamic substrate
biasing and also has approximately 96% lower power delay product
compared to only forward body biased at half of supply voltage. The
NMOS model used are predictive technology models of Arizona state
university and the simulations to be carried out using HSPICE
simulator.
Abstract: This paper designs the four-phase Boost Converter
which overcomes the problem of high input ripple current and output
ripple voltage. Digital control is more convenient for such a topology
on basis of synchronization, phase shift operation, etc. Simulation
results are presented for open-loop and closed-loop for four phase
boost converter. This control scheme is applicable for PFC rectifiers
as well. Thus a comparative analysis based on the obtained results is
performed.
Abstract: This paper explains about the voltage output for DC to
DC boost converter between open loop, PID controller and fuzzy
logic controller through Matlab Simulink. Simulink input voltage was
set at 12V and the voltage reference was set at 24V. The analysis on
the deviation of voltage resulted that the difference between reference
voltage setting and the output voltage is always lower. Comparison
between open loop, PID and FLC shows that, the open loop circuit
having a bit higher on the deviation of voltage. The PID circuit
boosts for FLC has a lesser deviation of voltage and proved that it is
such a better performance on control the deviation of voltage during
the boost mode.
Abstract: Hydrogenated amorphous carbon (a-C:H) films have
been synthesized by a radio frequency plasma enhanced chemical
vapor deposition (rf-PECVD) technique with different bias voltage
from 0.0 to -0.5 kV. The Raman spectra displayed the polymer-like
hydrogenated amorphous carbon (PLCH) film with 0.0 to -0.1 and
a-C:H films with -0.2 to -0.5 kV of bias voltages. The surface chemical
information of all films were studied by X-ray photoelectron
spectroscopy (XPS) technique, presented to C-C (sp2 and sp3) and C-O
bonds, and relative carbon (C) and oxygen (O) atomics contents. The
O contamination had affected on structure and optical properties. The
true density of PLCH and a-C:H films were characterized by X-ray
refractivity (XRR) method, showed the result as in the range of
1.16-1.73 g/cm3 that depending on an increasing of bias voltage. The
hardness was proportional to the true density of films. In addition, the
optical properties i.e. refractive index (n) and extinction coefficient (k)
of these films were determined by a spectroscopic ellipsometry (SE)
method that give formation to in 1.62-2.10 (n) and 0.04-0.15 (k)
respectively. These results indicated that the optical properties
confirmed the Raman results as presenting the structure changed with
applied bias voltage increased.
Abstract: Voltage sags are the most common power quality
disturbance in the distribution system. It occurs due to the fault in the
electrical network or by the starting of a large induction motor and
this can be solved by using the custom power devices such as
Dynamic Voltage Restorer (DVR). In this paper DVR is proposed to
compensate voltage sags on critical loads dynamically. The DVR
consists of VSC, injection transformers, passive filters and energy
storage (lead acid battery). By injecting an appropriate voltage, the
DVR restores a voltage waveform and ensures constant load voltage.
The simulation and experimental results of a DVR using MATLAB
software shows clearly the performance of the DVR in mitigating
voltage sags.
Abstract: This paper presents the electrical effect of two neighboring distribution substation during the construction phase. The size of auxiliary grounding grid have an effect on entire grounding system. The bigger the size of auxiliary grounding grid, the lower the GPR and maximum touch voltage, with the exception that when the two grids are unconnected, i.e. the bigger the size of auxiliary grounding grid, the higher the maximum step voltage. The results in this paper could be served as design guideline of grounding system, and perhaps remedy of some troublesome grounding grids in power distribution’s system. Modeling and simulation is carried out on the Current Distribution Electromagnetic interference Grounding and Soil structure (CDEGS) program. The simulation results exhibit the design and analysis of power system grounding and perhaps could be set as a standard in grounding system design and modification in distribution substations.
Abstract: The high efficiency power management IC (PMIC) with switching device is presented in this paper. PMIC is controlled with PFM control method in order to have high power efficiency at high current level. Dynamic Threshold voltage CMOS (DT-CMOS) with low on-resistance is designed to decrease conduction loss. The threshold voltage of DT-CMOS drops as the gate voltage increase, resulting in a much higher current handling capability than standard MOSFET. PFM control circuits consist of a generator, AND gate and comparator. The generator is made to have 1.2MHz oscillation voltage. The DC-DC converter based on PFM control circuit and low on-resistance switching device is presented in this paper.
Abstract: For Common R or R-L load to apply arbitrary voltage,
the bridge traditional inverters don’t have any difficulties by PWM
method. However for driving some piezoelectric actuator, arbitrary
voltage not a pulse but a steady voltage should be applied.
Piezoelectric load is considered as R-C load and its voltage does not
decrease even though the applied voltage decreases. Therefore it needs
some special inverter with circuit that can discharge the capacitive
energy. Especially for unidirectional arbitrary voltage driving like as
sine wave, it becomes more difficult problem. In this paper, a charge
and discharge circuit for unidirectional arbitrary voltage driving for
piezoelectric actuator is proposed. The circuit has charging and
discharging switches for increasing and decreasing output voltage.
With the proposed simple circuit, the load voltage can have any
unidirectional level with tens of bandwidth because the load voltage
can be adjusted by switching the charging and discharging switch
appropriately. The appropriateness is proved from the simulation of
the proposed circuit.
Abstract: The increasing penetration of Distributed Generation and storage connected to the distribution network via PWM converters increases the possibility of a DC-component (offset) in voltage or current flowing into the grid. This occurs when even harmonics are present in the network voltage. DC-components can affect the operation and safety of several grid components. Therefore, an investigation of the way they are produced is important in order to take appropriate measures for their elimination. Further research on DC-components that appear on output voltage of converters is performed for different parameters of PWM technique and characteristics of even harmonics.
Abstract: Nowadays the growth of distributed generation within the bulk power system is feasible by using the optimal control of the transmission lines power flow. Static Synchronous Compensators (STATCOM) is effective for improving voltage stability but it can only exchange reactive power with the power grid. The integration of Superconducting Magnetic Energy Storage (SMES) with a STATCOM can extend the traditional STATCOM capabilities to four-quadrant bulk power system power flow control and providing exchange both the active and reactive power related to the STATCOM with the ac network. This paper shows how the SMES system can be connected to the ac system via the DC bus of a STATCOM and also analyzes how the integration of STATCOM and SMES allows the bus voltage regulation and power oscillation damping (POD) to be achieved simultaneously. The dynamic performance of the integrated STATCOM-SMES is evaluated through simulation by using PSCAD/EMTDC software and the compensation effectiveness of this integrated compensator is shown.
Abstract: Due to the increased use of the power electronic equipment, harmonics in the power system has increased to a greater extent. These harmonics results a poor power quality causing a major effect on the customers. Shunt active filters (SHAF) are used for the mitigations of the current harmonics and to maintain constant DC link voltage. PI and Fuzzy logic controllers (FLC) were used to control the performance of the shunt active filter under both balance and unbalance source voltage condition. The results found were not satisfying the IEEE-519 standards of THD to be less than 5%. Hysteresis band current control was used to obtain the gating signals for SHAF, though it has some drawbacks and thus to obtain a better performance of the SHAF to mitigate the harmonics, adaptive hysteresis band current control scheme is implemented. Adaptive hysteresis based SHAF is used to obtain better compensation of current harmonics and to regulate the DC link voltage in a better way.