Abstract: The aim of the current work was to employ the finite
element method to model a slab, with a small hole across its width,
undergoing plastic plane strain deformation. The computational
model had, however, to be validated by comparing its results with
those obtained experimentally. Since they were in good agreement,
the finite element method can therefore be considered a reliable tool
that can help gain better understanding of the mechanism of ductile
failure in structural members having stress raisers. The finite element
software used was ANSYS, and the PLANE183 element was utilized.
It is a higher order 2-D, 8-node or 6-node element with quadratic
displacement behavior. A bilinear stress-strain relationship was used
to define the material properties, with constants similar to those of the
material used in the experimental study. The model was run for
several tensile loads in order to observe the progression of the plastic
deformation region, and the stress concentration factor was
determined in each case. The experimental study involved employing the visioplasticity
technique, where a circular mesh (each circle was 0.5 mm in
diameter, with 0.05 mm line thickness) was initially printed on the
side of an aluminum slab having a small hole across its width.
Tensile loading was then applied to produce a small increment of
plastic deformation. Circles in the plastic region became ellipses,
where the directions of the principal strains and stresses coincided
with the major and minor axes of the ellipses. Next, we were able to
determine the directions of the maximum and minimum shear
stresses at the center of each ellipse, and the slip-line field was then
constructed. We were then able to determine the stress at any point in
the plastic deformation zone, and hence the stress concentration
factor. The experimental results were found to be in good agreement
with the analytical ones.
Abstract: The design of high pressure water jet based polishing
equipment and its fabrication conducted in this study is reported
herein, together with some preliminary test results for assessing its
applicability for HMA surface polishing. This study also provides
preliminary findings concerning the test variables, such as the
rotational speed, the water jet pressure, the abrasive agent used, and
the impact angel that were experimentally investigated in this study. The preliminary findings based on four trial tests (two on large
slab specimens and two on small size gyratory compacted
specimens), however, indicate that both friction and texture values
tend to increase with the polishing durations for two combinations of
pressure and rotation speed of the rotary deck. It seems that the more
polishing action the specimen is subjected to; the aggregate edges are
created such that the surface texture values are increased with the
accompanied increase in friction values. It may be of interest (but
which is outside the scope of this study) to investigate if the similar
trend exist for HMA prepared with aggregate source that is sand and
gravel.
Abstract: The economic use and ease of construction of profiled
deck composite slab is marred with the complex and un-economic
strength verification required for the serviceability and general safety
considerations. Beside these, albeit factors such as shear span length,
deck geometries and mechanical frictions greatly influence the
longitudinal shear strength, that determines the ultimate strength of
profiled deck composite slab, and number of methods available for its
determination; partial shear and slope-intercept are the two methods
according to Euro-code 4 provision. However, the complexity
associated with shear behavior of profiled deck composite slab, the
use of these methods in determining the load carrying capacities of
such slab yields different and conflicting values. This couple with the
time and cost constraint associated with the strength verification is a
source of concern that draws more attentions nowadays, the issue is
critical. Treating some of these known shear strength influencing
factors as random variables, the load carrying capacity violation of
profiled deck composite slab from the use of the two-methods
defined according to Euro-code 4 are determined using reliability
approach, and comparatively studied. The study reveals safety values
from the use of m-k method shows good standing compared with that
from the partial shear method.
Abstract: An Australian manufacturer has fabricated an
innovative GFRP sandwich panel made from E-glass fiber skin and a
modified phenolic core for structural applications. Debonding, which
refers to separation of skin from the core material in composite
sandwiches, is one of the most common types of damage in
composites. The presence of debonding is of great concern because it
not only severely affects the stiffness but also modifies the dynamic
behaviour of the structure. Generally it is seen that the majority of
research carried out has been concerned about the delamination of
laminated structures whereas skin-core debonding has received
relatively minor attention. Furthermore it is observed that research
done on composite slabs having multiple skin-core debonding is very
limited. To address this gap, a comprehensive research investigating
dynamic behaviour of composite panels with single and multiple
debonding is presented. The study uses finite-element modelling and
analyses for investigating the influence of debonding on free
vibration behaviour of single and multilayer composite sandwich
panels. A broad parametric investigation has been carried out by
varying debonding locations, debonding sizes and support conditions
of the panels in view of both single and multiple debonding.
Numerical models were developed with Strand7 finite element
package by innovatively selecting the suitable elements to diligently
represent their actual behavior. Three-dimensional finite element
models were employed to simulate the physically real situation as
close as possible, with the use of an experimentally and numerically
validated finite element model. Comparative results and conclusions
based on the analyses are presented. For similar extents and locations
of debonding, the effect of debonding on natural frequencies appears
greatly dependent on the end conditions of the panel, giving greater
decrease in natural frequency when the panels are more restrained.
Some modes are more sensitive to debonding and this sensitivity
seems to be related to their vibration mode shapes. The fundamental
mode seems generally the least sensitive mode to debonding with
respect to the variation in free vibration characteristics. The results
indicate the effectiveness of the developed three dimensional finite
element models in assessing debonding damage in composite
sandwich panels.
Abstract: A large amount of blast furnace slag is generated in
China. Most ground granulated blast furnace slag (GGBS) however
ends up in low-grade applications. Blast furnace slag, ground to an
appropriate fineness, can be used as a partial replacement of
cementitious material in concrete. The potential for using GGBS in
structural concrete, e.g. concrete beams and columns is investigated
at Xi’an Jiaotong-Liverpool University (XJTLU). With 50% of CEM
I cement replaced with GGBS, peak hydration temperatures
determined in a suspended concrete slab reduced by 20%. This
beneficiary effect has not been further improved with 70% of CEM I
replaced with GGBS. Partial replacement of CEM I with GGBS has a
retardation effect on the early-age strength of concrete. More GGBS
concrete mixes will be conducted to identify an ‘optimum’
replacement level which will lead to a reduced thermal loading,
without significantly compromising the early-age strength of
concrete.
Abstract: The aim of this paper is to perform experimental
modal analysis (EMA) of reinforced concrete (RC) square slabs.
EMA is the process of determining the modal parameters (Natural
Frequencies, damping factors, modal vectors) of a structure from a
set of frequency response functions FRFs (curve fitting). Although,
experimental modal analysis (or modal testing) has grown steadily in
popularity since the advent of the digital FFT spectrum analyzer in
the early 1970’s, studying all types of members and materials using
such method have not yet been well documented. Therefore, in this
work, experimental tests were conducted on RC square slab
specimens of dimensions 600mm x 600mmx 40mm. Experimental
analysis was based on freely supported boundary condition.
Moreover, impact testing as a fast and economical means of finding
the modes of vibration of a structure was used during the
experiments. In addition, Pico Scope 6 device and MATLAB
software were used to acquire data, analyze and plot Frequency
Response Function (FRF). The experimental natural frequencies
which were extracted from measurements exhibit good agreement
with analytical predictions. It is showed that EMA method can be
usefully employed to investigate the dynamic behavior of RC slabs.
Abstract: This paper focuses on the dynamic behavior of
reinforced concrete (RC) slabs. Therefore, the theoretical modal
analysis was performed using two different types of boundary
conditions. Modal analysis method is the most important dynamic
analyses. The analysis would be modal case when there is no external
force on the structure. By using this method in this paper, the effects
of freely and simply supported boundary conditions on the
frequencies and mode shapes of RC square slabs are studied. ANSYS
software was employed to derive the finite element model to
determine the natural frequencies and mode shapes of the slabs.
Then, the obtained results through numerical analysis (finite element
analysis) would be compared with the exact solution. The main goal
of the research study is to predict how the boundary conditions
change the behavior of the slab structures prior to performing
experimental modal analysis. Based on the results, it is concluded
that simply support boundary condition has obvious influence to
increase the natural frequencies and change the shape of the mode
when it is compared with freely supported boundary condition of
slabs. This means that such support conditions have the direct
influence on the dynamic behavior of the slabs. Thus, it is suggested
to use free-free boundary condition in experimental modal analysis to
precisely reflect the properties of the structure. By using free-free
boundary conditions, the influence of poorly defined supports is
interrupted.
Abstract: The paper deals with current issues in research of
advanced methods to increase reliability of traditional timber
structural elements. It analyses the issue of strengthening of bent
timber beams, such as ceiling beams in old (historical) buildings with
additional concrete slab in combination with externally bonded fibre -
reinforced polymer. The paper describes experimental testing of
composite timber-concrete beam with FRP reinforcement and
compares results with FEM analysis.
Abstract: Well-designed composite steel and concrete structures
highlight the good material properties and lower the deficiencies of
steel and concrete, in particular they make use of high tensile strength
of steel and high stiffness of concrete. The most common composite
steel and concrete structure is a simply supported beam, which
concrete slab transferring the slab load to a beam is connected to the
steel cross-section. The aim of this paper is to find the most adequate
numerical model of a simply supported composite beam with the
cross-sectional and material parameters based on the results of a
processed parametric study and numerical analysis. The paper also
evaluates the suitability of using compact concrete with the
lightweight aggregates for composite steel and concrete beams. The
most adequate numerical model will be used in the resent future to
compare the results of laboratory tests.
Abstract: Formation of tensile cracks in concrete slabs of rigid pavement can be (among others) the initiation point of the other, more serious failures which can ultimately lead to complete degradation of the concrete slab and thus the whole pavement. Two measures can be used for reliability assessment of this phenomenon - the probability of failure and/or the reliability index. Different methods can be used for their calculation. The simple ones are called moment methods and simulation techniques. Two methods - FOSM Method and Simple Random Sampling Method - are verified and their comparison is performed. The influence of information about the probability distribution and the statistical parameters of input variables as well as of the limit state function on the calculated reliability index and failure probability are studied in three points on the lower surface of concrete slabs of the older type of rigid pavement formerly used in the Czech Republic.
Abstract: Damages from noise and vibration are increasing
every year, most of which are noises between floors in deteriorated
building caused by floor impact sound. In this study, the concrete slab
measured vibration impact sound for evaluation floor vibration of
deteriorated buildings that fails to satisfy with the minimum thickness.
In this experimental study, the vibration scale by impact sound was
calibrated and compared with ISO and AIJ standard for vibration. The
results show that vibration in slab with thickness used in existing
building reach human perception levels.
Abstract: The modern energy-efficient houses are often founded on a thermal insulation (TI) layer placed under the building’s RC foundation slab.The purpose of the paper is to identify the potential problems of the buildings founded on TI layer from the seismic point of view. The two main goals of the study were to assess the seismic behavior of such buildings, and to search for the critical structural parameters affecting the response of the superstructure as well as of the extruded polystyrene (XPS) layer. As a test building a multi-storeyed RC frame structure with and without the XPS layer under the foundation slab has been investigated utilizing nonlinear dynamic (time-history) and static (pushover) analyses. The structural response has been investigated with reference to the following performance parameters: i) Building’s lateral roof displacements, ii) Edge compressive and shear strains of the XPS, iii) Horizontal accelerations of the superstructure, iv) Plastic hinge patterns of the superstructure, v) Part of the foundation in compression, and vi) Deformations of the underlying soil and vertical displacements of the foundation slab (i.e. identifying the potential uplift). The results have shown that in the case of higher and stiff structures lying on firm soil the use of XPS under the foundation slab might induce amplified structural peak responses compared to the building models without XPS under the foundation slab. The analysis has revealed that the superstructure as well as the XPS response is substantially affected by the stiffness of the foundation slab.
Abstract: A mathematical heat transfer model for the prediction of transient heating of the slab in a direct-fired walking beam type reheating furnace has been developed by considering the nongray thermal radiation with given furnace environments. The furnace is modeled as radiating nongray medium with carbon dioxide and water with five-zoned gas temperature and the furnace wall is considered as a constant temperature lower than furnace gas one. The slabs are moving with constant velocity depending on the residence time through the non-firing, charging, preheating, heating, and final soaking zones. Radiative heat flux obtained by considering the radiative heat exchange inside the furnace as well as convective one from the surrounding hot gases are introduced as boundary condition of the transient heat conduction within the slab. After validating thermal radiation model adopted in this work, thermal fields in both model and real reheating furnace are investigated in terms of radiative heat flux in the furnace and temperature inside the slab. The results show that the slab in the furnace can be more heated with higher slab emissivity and residence time.
Abstract: Complex sensitivity analysis of stresses in a concrete slab of the real type of rigid pavement made from recycled materials is performed. The computational model of the pavement is designed as a spatial (3D) model, is based on a nonlinear variant of the finite element method that respects the structural nonlinearity, enables to model different arrangements of joints, and the entire model can be loaded by the thermal load. Interaction of adjacent slabs in joints and contact of the slab and the subsequent layer are modeled with the help of special contact elements. Four concrete slabs separated by transverse and longitudinal joints and the additional structural layers and soil to the depth of about 3m are modeled. The thickness of individual layers, physical and mechanical properties of materials, characteristics of joints, and the temperature of the upper and lower surface of slabs are supposed to be random variables. The modern simulation technique Updated Latin Hypercube Sampling with 20 simulations is used. For sensitivity analysis the sensitivity coefficient based on the Spearman rank correlation coefficient is utilized. As a result, the estimates of influence of random variability of individual input variables on the random variability of principal stresses s1 and s3 in 53 points on the upper and lower surface of the concrete slabs are obtained.
Abstract: The tremendous loss of life that resulted in the aftermath of recent earthquakes in developing countries is mostly due to the collapse of non-engineered and semi-engineered building structures. Such structures are used as houses, schools, primary healthcare centers and government offices. These building are classified structurally into two categories viz. non-engineered and semi-engineered. Non-engineered structures include: adobe, unreinforced masonry (URM) and wood buildings. Semi-engineered buildings are mostly low-rise (up to 3 story) light concrete frame structures or masonry bearing walls with reinforced concrete slab. This paper presents an overview of the typical damage observed in non-engineered structures and their most likely causes in the past earthquakes with specific emphasis on the performance of such structures in the 2005 Kashmir earthquake. It is demonstrated that seismic performance of these structures can be improved from life-safety viewpoint by adopting simple low-cost modifications to the existing construction practices. Incorporation of some of these practices in the reconstruction efforts after the 2005 Kashmir earthquake are examined in the last section for mitigating seismic risk hazard.
Abstract: Recently, an increasing trend of passive and low-energy buildings transferring form non earthquake-prone to earthquake-prone regions has thrown out the question about the seismic safety of such buildings. The paper describes the most commonly used thermal insulating materials and the special details, which could be critical from the point of view of earthquake resistance. The most critical appeared to be the cases of buildings founded on the RC foundation slab lying on a thermal insulation (TI) layer made of extruded polystyrene (XPS). It was pointed out that in such cases the seismic response of such buildings might differ to response of their fixed based counterparts. The main parameters that need special designers’ attention are: the building’s lateral top displacement, the ductility demand of the superstructure, the foundation friction coefficient demand, the maximum compressive stress in the TI layer and the percentage of the uplifted foundation. The analyses have shown that the potentially negative influences of inserting the TI under the foundation slab could be expected only for slender high-rise buildings subjected to severe earthquakes. Oppositely it was demonstrated for the foundation friction coefficient demand which could exceed the capacity value yet in the case of low-rise buildings subjected to moderate earthquakes. Some suggestions to prevent the horizontal shifts are also given.
Abstract: The International Building Code (IBC) and the
California Building Code (CBC) both recognize four basic types of
steel seismic resistant frames; moment frames, concentrically braced
frames, shear walls and eccentrically braced frames. Based on
specified geometries and detailing, the seismic performance of these
steel frames is well understood. In 2011, the authors designed an
innovative steel braced frame system with tapering members in the
general shape of a branching tree as a seismic retrofit solution to an
existing four story “lift-slab” building. Located in the seismically
active San Francisco Bay Area of California, a frame of this
configuration, not covered by the governing codes, would typically
require model or full scale testing to obtain jurisdiction approval.
This paper describes how the theories, protocols, and code
requirements of eccentrically braced frames (EBFs) were employed
to satisfy the 2009 International Building Code (IBC) and the 2010
California Building Code (CBC) for seismically resistant steel frames
and permit construction of these nonconforming geometries.
Abstract: Slab sliding system (SSS) with Coulomb friction
interface between slab and supporting frame is a passive structural
vibration control technology. The system can significantly reduce the
slab acceleration and accompanied lateral force of the frame. At the
same time it is expected to cause the slab displacement magnification
by sliding movement. To obtain the general comprehensive seismic
response of a single story structure, inelastic response spectra were
computed for a large ensemble of ground motions and a practical range
of structural periods and friction coefficient values. It was shown that
long period structures have no trade-off relation between force
reduction and displacement magnification with respect to elastic
response, unlike short period structures. For structures with the
majority of mass in the slab, the displacement magnification value can
be predicted according to simple inelastic displacement relation for
inelastically responding SDOF structures because the system behaves
elastically to a SDOF structure.
Abstract: The paper deals with current issues in research of advanced methods to increase reliability of traditional timber structural elements. It analyses the issue of strengthening of bent timber beams, such as ceiling beams in old (historical) buildings with additional concrete slab in combination with externally bonded fiber - reinforced polymer. The study evaluates deflection of a selected group of timber beams with concrete slab and additional CFRP reinforcement using different calculating methods and observes differences in results from different calculating methods. An elastic (EN 1995) calculation method and evaluation with FEM analysis software were used.
Abstract: Timber-concrete structures were recently introduced in Brazil as a viable option for bridge construction on side roads. Binding between timber and concrete is fundamentally important to assure the rigidity and performance of this structural system. The objective of this study was to assess the structural performance of a timber-concrete bridge prototype with width of 170cm and span of 400cm, whose binding among timber beams and concrete slabs was made with metal pins, obtained from CA 50 construction steel bars of 12.5mm diameter. It was possible to conclude, from the results obtained experimentally in laboratory, that the timber-concrete bridge prototype showed a good structural performance. This structural system provides an economical, rapid implementation solution, which may be used on side roads, favoring regional integration and agricultural production flow.