Abstract: This paper proposed a design of 16 elements, 8x2 linear fed patch antenna array with 16 ports, for 28 GHz, mm-wave band 5G for base station. The phased array covers along the azimuth plane to provide the coverage to the users in omnidirectional. The proposed antenna is designed RT Duroid 5880 substrate with the overall size of 85x35.6x0.787 mm3. The array is operating from 27.43 GHz to 28.34 GHz with a 910 MHz impedance bandwidth. The gain of the array is 18.3 dB, while the suppression of the side lobes is -1.0 dB. The main lobe direction of the array is 15 deg. The array shows a high array gain throughout the impedance bandwidth with overall of VSWR is below 1.12. The design will be proposed in single element and 16 elements antenna.
Abstract: To manage the demand of wireless communication that has been dramatically increased, switched beam antenna in smart antenna system is focused. Implementation of switched beam antennas at mobile terminals such as notebook or mobile handset is a preferable choice to increase the performance of the wireless communication systems. This paper proposes the low complexity switched beam antenna using single element of antenna which is suitable to implement at mobile terminal. Main beam direction is switched by changing the positions of short circuit on the radiating patch. There are four cases of switching that provide four different directions of main beam. Moreover, the performance in terms of Signal to Interference Ratio when utilizing the proposed antenna is compared with the one using omni-directional antenna to confirm the performance improvable.
Abstract: The paper presents the multi-element synthetic
transmit aperture (MSTA) method with a small number of elements
transmitting and all elements apertures in medical ultrasound
imaging. As compared to the other methods MSTA allows to
increase the system frame rate and provides the best compromise
between penetration depth and lateral resolution.
In the experiments a 128-element linear transducer array with
0.3 mm pitch excited by a burst pulse of 125 ns duration were used.
The comparison of 2D ultrasound images of tissue mimicking
phantom obtained using the STA and the MSTA methods is
presented to demonstrate the benefits of the second approach. The
results were obtained using SA algorithm with transmit and receive
signals correction based on a single element directivity function.
Abstract: The work describes the use of a synthetic transmit
aperture (STA) with a single element transmitting and all elements
receiving in medical ultrasound imaging. STA technique is a novel
approach to today-s commercial systems, where an image is acquired
sequentially one image line at a time that puts a strict limit on the
frame rate and the amount of data needed for high image quality. The
STA imaging allows to acquire data simultaneously from all
directions over a number of emissions, and the full image can be
reconstructed.
In experiments a 32-element linear transducer array with 0.48 mm
inter-element spacing was used. Single element transmission aperture
was used to generate a spherical wave covering the full image region.
The 2D ultrasound images of wire phantom are presented obtained
using the STA and commercial ultrasound scanner Antares to
demonstrate the benefits of the SA imaging.
Abstract: The paper presents the study of synthetic transmit
aperture method applying the Golay coded transmission for medical
ultrasound imaging. Longer coded excitation allows to increase the
total energy of the transmitted signal without increasing the peak
pressure. Signal-to-noise ratio and penetration depth are improved
maintaining high ultrasound image resolution.
In the work the 128-element linear transducer array with 0.3 mm
inter-element spacing excited by one cycle and the 8 and 16-bit
Golay coded sequences at nominal frequencies 4 MHz was used.
Single element transmission aperture was used to generate a spherical
wave covering the full image region and all the elements received the
echo signals. The comparison of 2D ultrasound images of the wire
phantom as well as of the tissue mimicking phantom is presented to
demonstrate the benefits of the coded transmission. The results were
obtained using the synthetic aperture algorithm with transmit and
receive signals correction based on a single element directivity
function.
Abstract: In the paper the study of synthetic transmit aperture
method applying the Golay coded transmission for medical
ultrasound imaging is presented. Longer coded excitation allows to
increase the total energy of the transmitted signal without increasing
the peak pressure. Moreover signal-to-noise ratio and penetration
depth are improved while maintaining high ultrasound image
resolution. In the work the 128-element linear transducer array with
0.3 mm inter-element spacing excited by one cycle and the 8 and 16-
bit Golay coded sequences at nominal frequency 4 MHz was used. To
generate a spherical wave covering the full image region a single
element transmission aperture was used and all the elements received
the echo signals. The comparison of 2D ultrasound images of the
tissue mimicking phantom and in vitro measurements of the beef liver
is presented to illustrate the benefits of the coded transmission. The
results were obtained using the synthetic aperture algorithm with
transmit and receive signals correction based on a single element
directivity function.
Abstract: Studies of vocal communication in Sooty-headed
Bulbul were carried out from January to December 2011. Vocal
recordings and behavioral observations were made in their natural
habitats at some localities of Lampang, Thailand. After editing, cuts
of high quality recordings were analyzed with the help of Avisoft-
SASLab Pro (version 4.40) software. More than one thousand
element repertoires in five groups were found within two vocal
structures. The two structures were short sounds with single element
and phrases composed of elements, the frequency ranged from 1-10
kHz. Most phrases were composed of 2 to 5 elements that were often
dissimilar in structure, however, these phrases were not as complex
as song phrases. The elements and phrases were combined to form
many patterns. The species used ten types of calls; i.e. alert, alarm,
aggressive, begging, contact, courtship, distress, exciting, flying and
invitation. Alert and contact calls were used more frequently than
other calls. Aggressive, alarm and distress calls could be used for
interspecific communication among some other bird species in the
same habitats.
Abstract: The empirical mode decomposition (EMD) represents any time series into a finite set of basis functions. The bases are termed as intrinsic mode functions (IMFs) which are mutually orthogonal containing minimum amount of cross-information. The EMD successively extracts the IMFs with the highest local frequencies in a recursive way, which yields effectively a set low-pass filters based entirely on the properties exhibited by the data. In this paper, EMD is applied to explore the properties of the multi-year air temperature and to observe its effects on climate change under global warming. This method decomposes the original time-series into intrinsic time scale. It is capable of analyzing nonlinear, non-stationary climatic time series that cause problems to many linear statistical methods and their users. The analysis results show that the mode of EMD presents seasonal variability. The most of the IMFs have normal distribution and the energy density distribution of the IMFs satisfies Chi-square distribution. The IMFs are more effective in isolating physical processes of various time-scales and also statistically significant. The analysis results also show that the EMD method provides a good job to find many characteristics on inter annual climate. The results suggest that climate fluctuations of every single element such as temperature are the results of variations in the global atmospheric circulation.