Abstract: The different seismic behavior of liquid storage tanks rather than conventional structures makes their responses more complicated. Uplifting and excessive settlement due to liquid sloshing are the most frequent damages in cylindrical liquid tanks after shell bucking failure modes. As a matter of fact, uses of liquid storage tanks because of the simple construction on compact layer of soil as a foundation are very conventional, but in some cases need to retrofit are essential. The tank seismic behavior can be improved by modifying dynamic characteristic of tank with verifying seismic loads as well as retrofitting and improving base ground. This paper focuses on a typical steel tank on loose, medium and stiff sandy soil and describes an evaluation of displacement of the tank before and after retrofitting. The Abaqus program was selected for its ability to include shell and structural steel elements, soil-structure interaction, and geometrical nonlinearities and contact type elements. The result shows considerable decreasing in settlement and uplifting in the case of retrofitted tank. Also, by increasing shear strength parameter of soil, the performance of the liquid storage tank under the case of seismic load increased.
Abstract: Cylindrical concrete reservoirs are appropriate choice
for storing liquids as water, oil and etc. By using of the pre-cast
concrete reservoirs instead of the in-situ constructed reservoirs, the
speed and precision of the construction would considerably increase.
In this construction method, wall and roof panels would make in
factory with high quality materials and precise controlling. Then,
pre-cast wall and roof panels would carry out to the construction site
for assembling. This method has a few faults such as: the existing
weeks in connection of wall panels together and wall panels to
foundation. Therefore, these have to be resisted under applied loads
such as seismic load. One of the innovative methods which was
successfully applied for seismic retrofitting of numerous pre-cast
cylindrical water reservoirs in New Zealand, using of the high tensile
cables around the reservoirs and post-tensioning them. In this paper,
analytical modeling of wall and roof panels and post-tensioned
cables are carried out with finite element method and the effect of
height to diameter ratio, post-tensioning force value, liquid level in
reservoir, installing position of tendons on seismic response of
reservoirs are investigated.
Abstract: The main objective of seismic rehabilitation in the
foundations is decreasing the range of horizontal and vertical
vibrations and omitting high frequencies contents under the seismic
loading. In this regard, the advantages of micropiles network is
utilized. Reduction in vibration range of foundation can be achieved
by using high dynamic rigidness module such as deep foundations. In
addition, natural frequency of pile and soil system increases in regard
to rising of system rigidness. Accordingly, the main strategy is
decreasing of horizontal and vertical seismic vibrations of the
structure. In this case, considering the impact of foundation, pile and
improved soil foundation is a primary concern. Therefore, in this
paper, effective factors are studied on the seismic rehabilitation of
foundations applying network micropiles in sandy soils with
nonlinear reaction.