Abstract: This paper presents the simulation the results of
electric field and potential distributions along surface of silicone
rubber polymer insulators. Near the same leakage distance subjected
to 15 kV in 50 cycle salt fog ageing test, alternate sheds silicone
rubber polymer insulator showed better contamination performance
than straight sheds silicone rubber polymer insulator. Severe surface
ageing was observed on the straight sheds insulator. The objective of
this work is to elucidate that electric field distribution along straight
sheds insulator higher than alternate shed insulator in salt fog ageing
test. Finite element method (FEM) is adopted for this work. The
simulation results confirmed the experimental data, as well.
Abstract: This paper presents the experimental results of salt fog ageing test of silicone rubber housing material for outdoor polymer insulator based on IEC 61109. Four types of HTV silicone rubber sheet with different amount of ATH were tested continuously 1000