Abstract: In this study, the different approaches currently followed by design codes to assess the stability of buildings utilizing concrete moment resisting frames structural system are evaluated. For such purpose, a parametric study was performed. It involved analyzing group of concrete moment resisting frames having different slenderness ratios (height/width ratios), designed for different lateral loads to vertical loads ratios and constructed using ordinary reinforced concrete and high strength concrete for stability check and overall buckling using code approaches and computer buckling analysis. The objectives were to examine the influence of such parameters that directly linked to frames’ lateral stiffness on the buildings’ stability and evaluates the code approach in view of buckling analysis results. Based on this study, it was concluded that, the most susceptible buildings to instability and magnification of second order effects are buildings having high aspect ratios (height/width ratio), having low lateral to vertical loads ratio and utilizing construction materials of high strength. In addition, the study showed that the instability limits imposed by codes are mainly mathematical to ensure reliable analysis not a physical ones and that they are in general conservative. Also, it has been shown that the upper limit set by one of the codes that second order moment for structural elements should be limited to 1.4 the first order moment is not justified, instead, the overall story check is more reliable.
Abstract: This paper presents the influence of the vertical
seismic component on the non-linear dynamics analysis of three
different structures. The subject structures were analyzed and
designed according to recent codes. This paper considers three types
of buildings: 5-, 10-, and 15-story buildings. The non-linear
dynamics analysis of the structures with assuming elastic-perfectlyplastic
behavior was performed using RAM PERFORM-3D software;
the horizontal component was taken into consideration with and
without the incorporation of the corresponding vertical component.
Dynamic responses obtained for the horizontal component acting
alone were compared with those obtained from the simultaneous
application of both seismic components. The results show that the
effect of the vertical component of ground motion may increase the
axial load significantly in the interior columns and, consequently, the
stories. The plastic mechanisms would be changed. The P-Delta
effect is expected to increase. The punching base plate shear of the
columns should be considered. Moreover, the vertical component
increases the input energy when the structures exhibit inelastic
behavior and are taller.
Abstract: This paper presents the influence of the vertical
seismic component on the non-linear dynamics analysis of three
different structures. The subject structures were analyzed and
designed according to recent codes. This paper considers three types
of buildings: 5-, 10-, and 15-story buildings. The non-linear dynamics
analysis of the structures with assuming elastic-perfectly-plastic
behavior was performed using RAM PERFORM-3D software; the
horizontal component was taken into consideration with and without
the incorporation of the corresponding vertical component. Dynamic
responses obtained for the horizontal component acting alone were
compared with those obtained from the simultaneous application of
both seismic components. The results show that the effect of the
vertical component of ground motion may increase the axial load
significantly in the interior columns and, consequently, the stories.
The plastic mechanisms would be changed. The P-Delta effect is
expected to increase. The punching base plate shear of the columns
should be considered. Moreover, the vertical component increases the
input energy when the structures exhibit inelastic behavior and are
taller.
Abstract: We study dynamic instability in high-rise steel moment
resisting frames (SMRFs) subjected to synthetic long-period ground
motions caused by hypothetical huge subduction earthquakes. Since
long duration as well as long dominant periods is a characteristic of
long-period ground motions, interstory drifts may enter the negative
postyield stiffness range many times when high-rise buildings are
subjected to long-period ground motions. Through the case studies of
9 high-rise SMRFs designed in accordance with the Japanese design
practice in 1980s, we demonstrate that drifting, or accumulation of
interstory drifts in one direction, occurs at the lower stories of the
SMRFs, if their natural periods are close to the dominant periods of the
long-period ground motions. The drifting led to residual interstory
drift ratio over 0.01, or to collapse if the design base shear was small.