Abstract: Improving the energy performance of existing buildings can be challenging, particularly when facades cannot be modified, and the only available option is internal insulation. In such cases, the choice of the most suitable material becomes increasingly complex, as in addition to thermal transmittance and capital cost, the designer needs to account for the impact of the intervention on the internal spaces, and in particular the loss of usable space due to the additional layers of materials installed. This paper explores this issue by analyzing a case study of an average office building needing to go through a refurbishment in order to reach the limits imposed by current regulations to achieve energy efficiency in buildings. The building is simulated through dynamic performance simulation under three different climate conditions in order to evaluate its energy needs. The use of Vacuum Insulated Panels as an option for energy refurbishment is compared to traditional insulation materials (XPS, Mineral Wool). For each scenario, energy consumptions are calculated and, in combination with their expected capital costs, used to perform a financial feasibility analysis. A holistic approach is proposed, taking into account the impact of the intervention on internal space by quantifying the value of the lost usable space and used in the financial feasibility analysis. The proposed approach highlights how taking into account different drivers will lead to the choice of different insulation materials, showing how accounting for the economic value of space can make VIPs an attractive solution for energy retrofitting under various climate conditions.
Abstract: The emergence of digital twin technology, a digital replica of physical world, has improved the real-time access to data from sensors about the performance of buildings. This digital transformation has opened up many opportunities to improve the management of the building by using the data collected to help monitor consumption patterns and energy leakages. One example is the integration of predictive models for anomaly detection. In this paper, we use the GAM (Generalised Additive Model) for the anomaly detection of Air Handling Units (AHU) power consumption pattern. There is ample research work on the use of GAM for the prediction of power consumption at the office building and nation-wide level. However, there is limited illustration of its anomaly detection capabilities, prescriptive analytics case study, and its integration with the latest development of digital twin technology. In this paper, we applied the general GAM modelling framework on the historical data of the AHU power consumption and cooling load of the building between Jan 2018 to Aug 2019 from an education campus in Singapore to train prediction models that, in turn, yield predicted values and ranges. The historical data are seamlessly extracted from the digital twin for modelling purposes. We enhanced the utility of the GAM model by using it to power a real-time anomaly detection system based on the forward predicted ranges. The magnitude of deviation from the upper and lower bounds of the uncertainty intervals is used to inform and identify anomalous data points, all based on historical data, without explicit intervention from domain experts. Notwithstanding, the domain expert fits in through an optional feedback loop through which iterative data cleansing is performed. After an anomalously high or low level of power consumption detected, a set of rule-based conditions are evaluated in real-time to help determine the next course of action for the facilities manager. The performance of GAM is then compared with other approaches to evaluate its effectiveness. Lastly, we discuss the successfully deployment of this approach for the detection of anomalous power consumption pattern and illustrated with real-world use cases.
Abstract: Piled raft foundations represent an efficient and reliable technique for transferring high vertical and horizontal loads to the subsoil. Piled raft foundations were successfully implemented for several high-rise buildings worldwide over the last decades. For the structural design of this foundation type the stiffnesses of both the piles and the raft have to be determined for the static (e.g. dead load, live load) and the dynamic load cases (e.g. earthquake). In this context the question often arises, to which proportion wind loads are to be considered as dynamic loads. Usually a piled raft foundation has to be monitored in order to verify the design hypotheses. As an additional benefit, the analysis of this monitoring data may lead to a better understanding of the behaviour of this foundation type for future projects in similar subsoil conditions. In case the measurement frequency is high enough, one may also draw conclusions on the effect of wind loading on the piled raft foundation. For a 41-storey office building in Basel, Switzerland, the preliminary design showed that a piled raft foundation was the best solution to satisfy both design requirements, as well as economic aspects. A high-frequency monitoring of the foundation including pile loads, vertical stresses under the raft, as well as pore water pressures was performed over 5 years. In windy situations the analysis of the measurements shows that the pile load increment due to wind consists of a static and a cyclic load term. As piles and raft react with different stiffnesses under static and dynamic loading, these measurements are useful for the correct definition of stiffnesses of future piled raft foundations. This paper outlines the design strategy and the numerical modelling of the aforementioned piled raft foundation. The measurement results are presented and analysed. Based on the findings, comments and conclusions on the definition of pile and raft stiffnesses for vertical and wind loading are proposed.
Abstract: Kabul city has suffered a lot in 40 years of conflict of civil war and “The war on terror”. After the invasion of Afghanistan by the United States of America and its allies in 2001, the Taliban was removed from operational power, but The Taliban and other terrorist groups remained in remote areas of the country, they started suicide attacks and bombings. Hence to protect from these attacks officials surrounded their office buildings and houses with concrete blast walls. It gives a bad landscape to the city and creates traffic congestions. Our research contains; questionnaire, reviewing Kabul Municipality documents and literature review. Questionnaires were distributed to Kabul citizens to find out how people feel by seeing the T-Walls on Kabul streets? And what problems they face with T-Walls. “The T-Walls pull down commission” of Kabul Municipality documents were reviewed to find out what caused the failure of this commission. A literature review has been done to compare Kabul with Washington D.C on how they designed the city against terrorism threat without turning the cities into lock down. Bogota city of Columbia urban happiness movement is reviewed and compared with Kabul. The finding of research revealed that citizens of Kabul want security but not at the expense of public realm and creating the architecture of fear. It also indicates that increasing the T-walls do not give secure feeling but instead; it increases terror, hatred and affect people’s optimism. At the end, a series of recommendation is suggested on the issue.
Abstract: In healthcare facilities, training the staff for firefighting and evacuation in real buildings is very challenging due to the presence of a vulnerable population in such an environment. In a standard environment, traditional approaches, such as fire drills, are often used to train the occupants and provide them with information about fire safety procedures. However, those traditional approaches may be inappropriate for a vulnerable population and can be inefficient from an educational viewpoint as it is impossible to expose the occupants to scenarios similar to a real emergency. Immersive serious games could be used as an alternative to traditional approaches to overcome their limitations. Serious games are already being used in different safety domains such as fires, earthquakes and terror attacks for several building types (e.g., office buildings, train stations, tunnels, etc.). In this study, we developed an immersive serious game to improve the fire safety skills of staff in healthcare facilities. An accurate representation of the healthcare environment was built in Unity3D by including visual and audio stimuli inspired from those employed in commercial action games. The serious game is organised in three levels. In each of them, the trainee is presented with a specific fire emergency and s/he can perform protective actions (e.g., firefighting, helping non-ambulant occupants, etc.) or s/he can ignore the opportunity for action and continue the evacuation. In this paper, we describe all the steps required to develop such a prototype, as well as the key questions that need to be answered, to develop a serious game for firefighting and evacuation in healthcare facilities.
Abstract: Shading devices (SDs) are widely used in buildings in the hot-humid climate areas for reducing cooling energy consumption for interior temperature, as the result of reducing the solar radiation directly. Contrasting the surface temperature of materials of SDs to the glass on the building façade could give more analysis for the shading effect. On the other side, SDs are much more used as the independence system on building façade in hot-humid area. This typical construction could have some impacts on building ventilation as well. This paper discusses the outdoor SDs’ effects on the building thermal environment and ventilation, through a set of measurements on a 2-floors office building in Guangzhou, China, which install a dynamic aluminum SD-system around the façade on 2nd-floor. The measurements recorded the in/outdoor temperature, relative humidity, velocity, and the surface temperature of the aluminum panel and the glaze. After that, a CFD simulation was conducted for deeper discussion of ventilation. In conclusion, this paper reveals the temperature differences on the different material of the façade, and finds that the velocity of indoor environment could be reduced by the outdoor SDs.
Abstract: Decentralized ventilation systems should combine a small and economical design with high aerodynamic and thermal efficiency. The Counter Flow Heat Recovery Fan (CHRF) provides the ability to meet these requirements by using only one cross flow fan with a large number of blades to generate both airflows and which simultaneously acts as a regenerative counter flow heat exchanger. The successful development of the first laboratory prototype has shown the potential of this ventilation system. Occurring condensate on the surfaces of the fan blades during the cold and dry season can be recovered through the characteristic mode of operation. Hence the CHRF provides the possibility to avoid the need for frost protection and condensate drain. Through the implementation of system-specific solutions for flow balancing and summer bypass the required functionality is assured. The scalability of the CHRF concept allows the use in renovation as well as in new buildings from single-room devices through to systems for office buildings. High aerodynamic and thermal efficiency and the lower number of required mechatronic components should enable a reduction in investment as well as operating costs. The rotor is the key component of the system, the requirements and possible implementation variants are presented.
Abstract: This research responded to anecdotal evidence that suggested inefficiencies within the Architect and Acoustician relationship may lead to ineffective acoustic design decisions. The acoustician spoken to believed that he was approached too late in the design phase. The approached architect valued acoustical qualities, yet, struggled to interpret common measurement parameters. The preliminary investigation of these opinions indicated a gap in the current New Zealand Architectural discourse and currently informs the creation of a 2016 Master of Architecture (Prof) thesis research. Little meaningful information about acoustic intervention in the early design phase could be found from past literature. In the information that was sourced, authors focus on software as an incorporation tool without investigating why the flaws in the relationship originally exist. To further explore this relationship, a survey was designed. It underwent three phases to ensure its consistency, and was delivered to a group of 51 acousticians from one international Acoustics company. The results were then separated between New Zealand and off-shore to identify trends. The survey results suggest that 75% of acousticians meet the architect less than 5 times per project. Instead of regular contact, a mediated method is adopted though a mix of telecommunication and written reports. Acousticians tend to be introduced later into New Zealand building project than the corresponding off-shore building. This delay corresponds to an increase in remedial action for each of the building types in the survey except Auditoria and Office Buildings. 31 participants have had their specifications challenged by an architect. Furthermore, 71% of the acousticians believe that architects do not have the knowledge to understand why the acoustic specifications are in place. The issues raised in this investigation align to the colloquial evidence expressed by the two consultants. It identifies a larger gap in the industry were acoustics is remedially treated rather than identified as a possible design driver. Further research through design is suggested to understand the role of acoustics within architectural design and potential tools for its inclusion during, not after, the design process.
Abstract: In recent years, the power system has been changed
and a flexible power pricing system such as demand response has been
sought in Japan. The demand response system works simply in the
household sector and the owner as the decision-maker, can benefit
from power saving. On the other hand, the execution of demand
response in the office building is more complex than in the household
because various people such as owners, building administrators and
occupants are involved in the decision-making process. While the
owners benefit from demand saving, the occupants are exposed to
restricted benefits of a demand-saved environment. One of the reasons
is that building systems are usually under centralized management and
each occupant cannot choose freely whether to participate in demand
response or not. In addition, it is unclear whether incentives give
occupants the motivation to participate. However, the recent
development of IT and building systems enables the personalized
control of the office environment where each occupant can control the
lighting level or temperature individually. Therefore, it can be possible
to have a system which each occupant can make a decision of whether
or not to participate in demand response in the office building. This study investigates personal responses to demand response
requests, under the condition where each occupant can adjust their
brightness individually in their workspace. Once workers participate
in the demand response, their desk-lights are automatically turned off.
The participation rates in the demand response events are compared
among four groups, which are divided by different motivation, the
presence, or absence of incentives and the method of participation. The
result shows that there are significant differences of participation rates
in demand response event between four groups. The method of
participation has a large effect on the participation rate. The “Opt-out”
groups where the occupants are automatically enrolled in a demand
response event if they do not express non-participation have the
highest participation rate in the four groups. Incentives also have an
effect on the participation rate. This study also reports on the impact of low illumination office
environment on the occupants, such as stress or fatigue. The
electrocardiogram and the questionnaire are used to investigate the
autonomic nervous activity and subjective fatigue symptoms of the
occupants. There is no big difference between dim workspace during
demand response event and bright workspace in autonomic nervous
activity and fatigue.
Abstract: Malaysia’s green building development is gaining
momentum and green buildings have become a key focus area,
especially within the commercial sector with the encouragement of
government legislation and policy. Due to the emerging awareness
among the market players’ views of the benefits associated with the
ownership of green buildings in Malaysia, there is a need for valuers
to incorporate consideration of sustainability into their assessments of
property market value to ensure the green buildings continue to
increase in the market. This paper analyses the valuers’ current
perception on the valuation practices with regard to the green issues
in Malaysia. The study was based on a survey of registered real estate
valuers and the experts whose work related to valuation in the Klang
Valley area to rate their view regarding the perception on valuation of
green building. The findings present evidence that even though
Malaysian valuers have limited knowledge of green buildings, they
recognise the importance of incorporating the green features in the
valuation process. The inclusion of incorporating the green features
in valuations in practice was hindered by the inadequacy of sufficient
transaction data in the market. Furthermore, valuers experienced
difficulty in identifying what are the various input parameters of
green building and how to adjust it in order to reflect the benefit of
sustainability features correctly in the valuation process. This paper
focuses on the present challenges confronted by Malaysian valuers
with regards to incorporating the green features in their valuation.
Abstract: Energy consumption and users’ satisfaction were
compared in three LEED certified office buildings in turkey and an
office building in Egypt. The field studies were conducted in summer
2012. The measured environmental parameters in the four buildings
were indoor air temperature, relative humidity, CO2 percentage and
light intensity. The traditional building is located in Smart Village in
Abu Rawash, Cairo, Egypt. The building was studied for 7 days
resulting in 84 responds. The three rated buildings are in Istanbul;
Turkey. A Platinum LEED certified office building is owned by
BASF and gained a platinum certificate for new construction and
major renovation. The building was studied for 3 days resulting in 13
responds. A Gold LEED certified office building is owned by BASF
and gained a gold certificate for new construction and major
renovation. The building was studied for 2 days resulting in 10
responds. A silver LEED certified office building is owned by
Unilever and gained a silver certificate for commercial interiors. The
building was studied for 7 days resulting in 84 responds.
The results showed that all buildings had no significant difference
regarding occupants’ satisfaction with the amount of lighting, noise
level, odor and access to the outdoor view. There was significant
difference between occupants’ satisfaction in LEED certified
buildings and the traditional building regarding the thermal
environment and the perception of the general environment (colors,
carpet and decoration. The findings suggest that careful design could
lead to a certified building that enhances the thermal environment and
the perception of the indoor environment leading to energy
consumption without scarifying occupants’ satisfaction.
Abstract: Sustainable tall buildings that provide comfortable,
healthy and efficient indoor environments are clearly desirable as the
densification of living and working space for the world’s increasing
population proceeds. For environmental concerns, these buildings
must also be energy efficient. One component of these tasks is the
provision of indoor air quality and thermal comfort, which can be
enhanced with natural ventilation by the supply of fresh air. Working
spaces can only be naturally ventilated with connections to the
outdoors utilizing operable windows, double facades, ventilation
stacks, balconies, patios, terraces and skygardens. Large amounts of
fresh air can be provided to the indoor spaces without mechanical
air-conditioning systems, which are widely employed in
contemporary tall buildings.
This paper tends to present the concept of natural ventilation for
sustainable tall office buildings in order to achieve healthy and
comfortable working spaces, as well as energy efficient
environments. Initially the historical evolution of ventilation
strategies for tall buildings is presented, beginning with natural
ventilation and continuing with the introduction of mechanical airconditioning
systems. Then the emergence of natural ventilation due
to the health and environmental concerns in tall buildings is handled,
and the strategies for implementing this strategy are revealed. In the
next section, a number of case studies that utilize this strategy are
investigated. Finally, how tall office buildings can benefit from this
strategy is discussed.
Abstract: This study examines the stack ventilation performance of an office building located in Taipei, Taiwan. Atriums in this building act as stacks that facilitate buoyancy-driven ventilation. Computational Fluid Dynamic (CFD) simulations are used to identify interior airflow patterns, and then used these patterns to assess the building’s heat expulsion efficiency. Ambient temperatures of 20°C were adopted as the typical seasonal spring temperature range in Taipei. Further, “zero-wind” conditions are established to ensure simulation results reflected only the buoyancy effect. After checking results against neutral pressure level (NPL) level, airflow, air velocity, and indoor temperature stratification, the lower stack is modified to reduce the NPL in order to remove heat accumulated on the top floor.
Abstract: In recent years, there has been an increasing interest in using daylight to save energy in buildings. In tropical regions, daylighting is always an energy saver. On the other hand, daylight provides visual comfort. According to standards, it shows that many criteria should be taken into consideration in order to have daylight utilization and visual comfort. The current standard in Malaysia, MS 1525 does not provide sufficient guideline. Hence, more research is needed on daylight performance. If architects do not consider daylight design, it not only causes inconvenience in working spaces but also causes more energy consumption as well as environmental pollution. This research had surveyed daylight performance in 5 selected office buildings from different area of Malaysian through experimental method. Several parameters of daylight quality such as daylight factor, surface luminance and surface luminance ratio were measured in different rooms in each building. The result of this research demonstrated that most of the buildings were not designed for daylight utilization. Therefore, it is very important that architects follow the daylight design recommendation to reduce consumption of electric power for artificial lighting while the sufficient quality of daylight is available.
Abstract: Sustainable energy usage has been recognized as one
of the important measure to increase the competitiveness of the
nation globally. Many strong emphases were given in the Ninth
Malaysia Plan (RMK9) to improve energy efficient especially to
government buildings. With this in view, a project to investigate the
potential of energy saving in selected building in Universiti Tun
Hussein Onn Malaysia (UTHM) was carried out. In this project, a
case study involving electric energy consumption of the academic
staff office building was conducted. The scope of the study include to
identify energy consumption in a selected building, to study energy
saving opportunities, to analyse cost investment in term of economic
and to identify users attitude with respect to energy usage. The
MS1525:2001, Malaysian Standard -Code of practice on energy
efficiency and use of renewable energy for non-residential buildings
was used as reference. Several energy efficient measures were
considered and their merits and priority were compared. Improving
human behavior can reduce energy consumption by 6% while
technical measure can reduce energy consumption by 44%. Two
economic analysis evaluation methods were applied; they are the
payback period method and net present value method.
Abstract: Air conditioning is mainly use as human comfort
cooling medium. It use more in high temperatures are country such as
Malaysia. Proper estimation of cooling load will archive ideal
temperature. Without proper estimation can lead to over estimation or
under estimation. The ideal temperature should be comfort enough.
This study is to develop a program to calculate an ideal cooling load
demand, which is match with heat gain. Through this study, it is easy
to calculate cooling load estimation. Objective of this study are to
develop user-friendly and easy excess cooling load program. This is
to insure the cooling load can be estimate by any of the individual
rather than them using rule-of-thumb. Developed software is carryout
by using Matlab-GUI. These developments are only valid for
common building in Malaysia only. An office building was select as
case study to verify the applicable and accuracy of develop software.
In conclusion, the main objective has successfully where developed
software is user friendly and easily to estimate cooling load demand.
Abstract: The purpose of this paper is to investigate the adjust-
ment of solar shading devices in office buildings in two different
seasons by occupants, and its influence on the lighting control and
indoor illuminance levels. The results show that occupants take
inappropriate measures both in reducing solar radiation in summer
and in admitting solar gains in winter, resulting in an increase in
lighting energy and a reduction in indoor illuminance. Therefore,
movable shading devices, controlled automatically, are suitable for