Abstract: A numerical prediction of flow in a tube bank is reported. The flow regimes considered cover a wide range of Reynolds numbers, which range from 380 to 99000 and which are equivalent to a range of inlet velocities from very low (0.072 m/s) to very high (60 m/s). In this study, calculations were made using the standard k-e model with standard wall function. The drag coefficient, skin friction drag, pressure drag, and pressure distribution around a tube were investigated. As the velocity increased, the drag coefficient decreased until the velocity exceeded 45 m/s, after which it increased. Furthermore, the pressure drag and skin friction drag depend on the velocity.
Abstract: This analysis investigates the distortion of flow
measurement and the increase of cavitation along orifice
flowmeter. The analysis using the numerical method (CFD)
validated the distortion of flow measurement through the inlet
velocity profile considering the convergence and grid
dependency. Realizable k-e model was selected and y+ was
about 50 in this numerical analysis. This analysis also estimated
the vulnerability of cavitation effect due to inlet velocity profile.
The investigation concludes that inclined inlet velocity profile
could vary the pressure which was measured at pressure tab
near pipe wall and it led to distort the pressure values ranged
from -3.8% to 5.3% near the orifice plate and to make the
increase of cavitation. The investigation recommends that the
fully developed inlet velocity flow is beneficial to accurate flow
measurement in orifice flowmeter.