Abstract: This analysis investigates the distortion of flow
measurement and the increase of cavitation along orifice
flowmeter. The analysis using the numerical method (CFD)
validated the distortion of flow measurement through the inlet
velocity profile considering the convergence and grid
dependency. Realizable k-e model was selected and y+ was
about 50 in this numerical analysis. This analysis also estimated
the vulnerability of cavitation effect due to inlet velocity profile.
The investigation concludes that inclined inlet velocity profile
could vary the pressure which was measured at pressure tab
near pipe wall and it led to distort the pressure values ranged
from -3.8% to 5.3% near the orifice plate and to make the
increase of cavitation. The investigation recommends that the
fully developed inlet velocity flow is beneficial to accurate flow
measurement in orifice flowmeter.
Abstract: The present paper represents a methodology for
investigating flow characteristics near orifice plate by using a
commercial computational fluid dynamics code. The flow
characteristics near orifice plate which is located in the auxiliary
feedwater system were modeled via three different levels of grid and
four different types of Reynolds Averaged Navier-Stokes (RANS)
equations with proper near-wall treatment. The results from CFD code
were compared with experimental data in terms of differential pressure
through the orifice plate. In this preliminary study, the Realizable k-ε
and the Reynolds stress models with enhanced wall treatment were
suitable to analyze flow characteristics near orifice plate, and the
results had a good agreement with experimental data.