Abstract: The aim of presented research was to improve numerical predictions of air parameters distribution in the actual natatorium by the selection of calculation formula of mass flux of moisture emitted from the pool. Selected correlation should ensure the best compliance of numerical results with the measurements' results of these parameters in the facility. The numerical model of the natatorium was developed, for which boundary conditions were prepared on the basis of measurements' results carried out in the actual facility. Numerical calculations were carried out with the use of ANSYS CFX software, with six formulas being implemented, which in various ways made the moisture emission dependent on water surface temperature and air parameters in the natatorium. The results of calculations with the use of these formulas were compared for air parameters' distributions: Specific humidity, velocity and temperature in the facility. For the selection of the best formula, numerical results of these parameters in occupied zone were validated by comparison with the measurements' results carried out at selected points of this zone.
Abstract: Passive design responds to improve indoor thermal comfort and minimize the energy consumption. The present research analyzed the how efficiently passive solar technologies generate heating and cooling and provide the system integration for domestic applications. In addition to this, the aim of this study is to increase the efficiency of solar systems system with integration some innovation and optimization. As a result, outputs of the project might start a new sector to provide environmentally friendly and cheap cooling for domestic use.
Abstract: Experimental results confirmed the temporal variation of carbon dioxide and carbon monoxide concentration during the working shift of the photocopying process in a small photocopying shop in Novi Sad, Serbia. The statistically significant differences of target gases were examined with two-way analysis of variance without replication followed by Scheffe's post hoc test. The existence of statistically significant differences was obtained for carbon monoxide emission which is pointed out with F-values (12.37 and 31.88) greater than Fcrit (6.94) in contrary to carbon dioxide emission (F-values of 1.23 and 3.12 were less than Fcrit). Scheffe's post hoc test indicated that sampling point A (near the photocopier machine) and second time interval contribute the most on carbon monoxide emission.
Abstract: In this paper, propose method that can user’s position
that based on database is built from single camera. Previous
positioning calculate distance by arrival-time of signal like GPS
(Global Positioning System), RF(Radio Frequency). However, these
previous method have weakness because these have large error range
according to signal interference. Method for solution estimate position
by camera sensor. But, signal camera is difficult to obtain relative
position data and stereo camera is difficult to provide real-time
position data because of a lot of image data, too. First of all, in this
research we build image database at space that able to provide
positioning service with single camera. Next, we judge similarity
through image matching of database image and transmission image
from user. Finally, we decide position of user through position of most
similar database image. For verification of propose method, we
experiment at real-environment like indoor and outdoor. Propose
method is wide positioning range and this method can verify not only
position of user but also direction.
Abstract: Design criteria for achieving an acceptable indoor radon concentration are presented in this paper. The paper suggests three design criteria. These criteria have to be considered at the early stage of the building design phase to meet the latest recommendations from the World Health Organization in most countries. The three design criteria are; first, establishing a radon barrier facing the ground; second, lowering the air pressure in the lower zone of the slab on ground facing downwards; third, diluting the indoor air with outdoor air. The first two criteria can prevent radon from infiltrating from the ground, and the third criteria can dilute the indoor air. By combining these three criteria, the indoor radon concentration can be lowered achieving an acceptable level. In addition, a cheap and reliable method for measuring the radon concentration in the indoor air is described. The provision on radon in the Danish Building Regulations complies with the latest recommendations from the World Health Organization. Radon can cause lung cancer and it is not known whether there is a lower limit for when it is not harmful to human beings. Therefore, it is important to reduce the radon concentration as much as possible in buildings. Airtightness is an important factor when dealing with buildings. It is important to avoid air leakages in the building envelope both facing the atmosphere, e.g. in compliance with energy requirements, but also facing the ground, to meet the requirements to ensure and control the indoor environment. Infiltration of air from the ground underneath a building is the main providing source of radon to the indoor air.
Abstract: The recent tendency of ”Internet of Things” (IoT) has
developed in the last years, causing the emergence of innovative
communication methods among multiple devices. The appearance of
Bluetooth Low Energy (BLE) has allowed a push to IoT in relation
to smartphones. In this moment, a set of new applications related to
several topics like entertainment and advertisement has begun to be
developed but not much has been done till now to take advantage
of the potential that these technologies can offer on many business
areas and in everyday tasks. In the present work, the application of
BLE technology and smartphones is proposed on some business areas
related to the optimization of resource allocation in huge facilities
like airports. An indoor location system has been developed through
triangulation methods with the use of BLE beacons. The described
system can be used to locate all employees inside the building
in such a way that any task can be automatically assigned to a
group of employees. It should be noted that this system cannot
only be used to link needs with employees according to distances,
but it also takes into account other factors like occupation level or
category. In addition, it has been endowed with a security system
to manage business and personnel sensitive data. The efficiency of
communications is another essential characteristic that has been taken
into account in this work.
Abstract: A human’s hand localization is revised by using radar cross section (RCS) measurements with a minimum root mean square (RMS) error matching algorithm on a touchless keypad mock-up model. RCS and frequency transfer function measurements are carried out in an indoor environment on the frequency ranged from 3.0 to 11.0 GHz to cover federal communications commission (FCC) standards. The touchless keypad model is tested in two different distances between the hand and the keypad. The initial distance of 19.50 cm is identical to the heights of transmitting (Tx) and receiving (Rx) antennas, while the second distance is 29.50 cm from the keypad. Moreover, the effects of Rx angles relative to the hand of human factor are considered. The RCS input parameters are compared with power loss parameters at each frequency. From the results, the performance of the RCS input parameters with the second distance, 29.50 cm at 3 GHz is better than the others.
Abstract: Recently, the world main problem is a global warming and climate change affecting both outdoor and indoor environments, especially the air quality (AQ) as a result of vast migration of people from rural areas to urban areas. Therefore, cities became more crowded and denser from an irregular population increase, along with increasing urbanization caused many problems for the environment such as increasing the land prices, changes in life style, and the new buildings are not adapted to the climate producing uncomfortable and unhealthy indoor building conditions. As interior environments are the places that create the most intimate relationship with the user. Consequently, the indoor environment quality (IEQ) for buildings became uncomfortable and unhealthy for its occupants. The symptoms commonly associated with poor indoor environment such as itchy, headache, fatigue, and respiratory complaints such as cough and congestion, etc. The symptoms tend to improve over time or even disappear when people are away from the building. Therefore, designing a healthy indoor environment to fulfill human needs is the main concern for architects and interior designer. However, this research explores how occupant expectations and environmental attitudes may influence occupant health and satisfaction within the context of the indoor environment. In doing so, it reviews and contributes to the methods and tools used to evaluate only the indoor environment quality (IEQ) components of building performance. Its main aim is to review the literature on indoor human comfort. This is followed by a review of previous papers published related to human comfort. Finally, this paper will provide possible approaches in design level of healthy buildings.
Abstract: Device-to-device (D2D) communication is considered a
promising technique to provide wireless peer-to-peer communication
services. Due to increasing demand on mobile services, available
spectrum for radio frequency (RF) based communications becomes
scarce. Recently, visible light communications (VLC) has evolved
as a high speed wireless data transmission technology for indoor
environments with abundant available bandwidth. In this paper,
a novel VLC based D2D communication that provides wireless
peer-to-peer communication is proposed. Potential low operating
power devices for an efficient D2D communication over increasing
distance of separation between devices is analyzed. Optical repeaters
(OR) are also proposed to enhance the performance in an environment
where direct D2D communications yield degraded performance.
Simulation results show that VLC plays an important role in
providing efficient D2D communication up to a distance of 1 m
between devices. It is also found that the OR significantly improves
the coverage distance up to 3.5 m.
Abstract: An analysis of the air tightness level is performed on a representative sample of school classrooms in Southern Spain, which allows knowing the infiltration level of these classrooms, mainly through its envelope, which can affect both energy demand and occupant's thermal comfort. By using a pressurization/depressurization equipment (Blower-Door test), a characterization of 45 multipurpose classrooms have been performed in nine non-university educational institutions of the main climate zones of Southern Spain. In spite of having two doors and a high ratio between glass surface and outer surface, it is possible to see in these classrooms that there is an adequate level of airtightness, since all the n50 values obtained are lower than 9.0 ACH, with an average value around 7.0 ACH.
Abstract: The purposes of hydraulic gate are to maintain the
functions of storing and draining water. It bears long-term hydraulic
pressure and earthquake force and is very important for reservoir and
waterpower plant. The high tensile strength of steel plate is used as
constructional material of hydraulic gate. The cracks and rusts,
induced by the defects of material, bad construction and seismic
excitation and under water respectively, thus, the mechanics
phenomena of gate with crack are probing into the cause of stress
concentration, induced high crack increase rate, affect the safety and
usage of hydroelectric power plant. Stress distribution analysis is a
very important and essential surveying technique to analyze
bi-material and singular point problems. The finite difference
infinitely small element method has been demonstrated, suitable for
analyzing the buckling phenomena of welding seam and steel plate
with crack. Especially, this method can easily analyze the singularity
of kink crack. Nevertheless, the construction form and deformation
shape of some gates are three-dimensional system. Therefore, the
three-dimensional Digital Image Correlation (DIC) has been
developed and applied to analyze the strain variation of steel plate with
crack at weld joint. The proposed Digital image correlation (DIC)
technique is an only non-contact method for measuring the variation of
test object. According to rapid development of digital camera, the cost
of this digital image correlation technique has been reduced.
Otherwise, this DIC method provides with the advantages of widely
practical application of indoor test and field test without the restriction
on the size of test object. Thus, the research purpose of this research is
to develop and apply this technique to monitor mechanics crack
variations of weld steel hydraulic gate and its conformation under
action of loading. The imagines can be picked from real time
monitoring process to analyze the strain change of each loading stage.
The proposed 3-Dimensional digital image correlation method,
developed in the study, is applied to analyze the post-buckling
phenomenon and buckling tendency of welded steel plate with crack.
Then, the stress intensity of 3-dimensional analysis of different
materials and enhanced materials in steel plate has been analyzed in
this paper. The test results show that this proposed three-dimensional
DIC method can precisely detect the crack variation of welded steel
plate under different loading stages. Especially, this proposed DIC
method can detect and identify the crack position and the other flaws
of the welded steel plate that the traditional test methods hardly detect
these kind phenomena. Therefore, this proposed three-dimensional
DIC method can apply to observe the mechanics phenomena of
composite materials subjected to loading and operating.
Abstract: This paper presents the design and implementation
details of a complete unmanned aerial system (UAS) based
on commercial-off-the-shelf (COTS) components, focusing on
safety, security, search and rescue scenarios in GPS-denied
environments. In particular, The aerial platform is capable
of semi-autonomously navigating through extremely low-light,
GPS-denied indoor environments based on onboard sensors only,
including a downward-facing optical flow camera. Besides, an
additional low-cost payload camera system is developed to stream
both infra-red video and visible light video to a ground station in
real-time, for the purpose of detecting sign of life and hidden humans.
The total cost of the complete system is estimated to be $1150,
and the effectiveness of the system has been tested and validated
in practical scenarios.
Abstract: The relationship dependence between RSS and distance
in an enclosed environment is an important consideration because it is
a factor that can influence the reliability of any localization algorithm
founded on RSS. Several algorithms effectively reduce the variance of
RSS to improve localization or accuracy performance. Our proposed
algorithm essentially avoids this pitfall and consequently, its high
adaptability in the face of erratic radio signal. Using 3 anchors in
close proximity of each other, we are able to establish that RSS can be
used as reliable indicator for localization with an acceptable degree of
accuracy. Inherent in this concept, is the ability for each prospective
anchor to validate (guarantee) the position or the proximity of the
other 2 anchors involved in the localization and vice versa. This
procedure ensures that the uncertainties of radio signals due to
multipath effects in enclosed environments are minimized. A major
driver of this idea is the implicit topological relationship among
sensors due to raw radio signal strength. The algorithm is an area
based algorithm; however, it does not trade accuracy for precision
(i.e the size of the returned area).
Abstract: The development of composite materials and the
related design and manufacturing technologies is one of the most
important advances in the history of materials. Composites are
multifunctional materials having unprecedented mechanical and
physical properties that can be tailored to meet the requirements of a
particular application. Some composites also exhibit great resistance
to high-temperature corrosion, oxidation, and wear. Polymers are
widely used indoors and outdoors, therefore they are exposed to a
chemical environment which may include atmospheric oxygen, acidic
fumes, acidic rain, moisture heat and thermal shock, ultra-violet light,
high energy radiation, etc. Different polymers are affected differently
by these factors even though the amorphous polymers are more
sensitive. Ageing is also important and it is defined as the process of
deterioration of engineering materials resulting from the combined
effects of atmospheric radiation, heat, oxygen, water, microorganisms
and other atmospheric factors.
Abstract: Ultraviolet photocatalytic oxidation (UV-PCO)
technology has been recommended as a green approach to health
indoor environment when it is integrated into mechanical ventilation
systems for inorganic and organic compounds removal as well as
energy saving due to less outdoor air intakes. Although much research
has been devoted to UV-PCO, limited information is available on the
UV-PCO behavior tested by the mixtures in literature. This project
investigated UV-PCO performance and by-product generation using a
single and a mixture of acetone and MEK at 100 ppb each in a
single-pass duct system in an effort to obtain knowledge associated
with competitive photochemical reactions involved in. The
experiments were performed at 20 % RH, 22 °C, and a gas flow rate of
128 m3/h (75 cfm). Results show that acetone and MEK mutually
reduced each other’s PCO removal efficiency, particularly negative
removal efficiency for acetone. These findings were different from
previous observation of facilitatory effects on the adsorption of
acetone and MEK on photocatalyst surfaces.
Abstract: This study was carried out for an underground subway station at Seoul Metro, Korea. The optimal set-points of the ventilation control system are determined every 3 hours, then, the ventilation controller adjusts the ventilation fan speed according to the optimal set-point changes. Compared to manual ventilation system which is operated irrespective of the OAQ, the IDP-based ventilation control system saves 3.7% of the energy consumption. Compared to the fixed set-point controller which is operated irrespective of the IAQ diurnal variation, the IDP-based controller shows better performance with a 2% decrease in energy consumption, maintaining the comfortable IAQ range inside the station.
Abstract: This study addresses a concept of the Sustainable Building Environmental Model (SBEM) developed to optimize energy consumption in air conditioning and ventilation (ACV) systems without any deterioration of indoor environmental quality (IEQ). The SBEM incorporates two main components: an adaptive comfort temperature control module (ACT) and a new carbon dioxide demand control module (nDCV). These two modules take an innovative approach to maintain satisfaction of the Indoor Environmental Quality (IEQ) with optimum energy consumption; they provide a rational basis of effective control. A total of 2133 sets of measurement data of indoor air temperature (Ta), relative humidity (Rh) and carbon dioxide concentration (CO2) were conducted in some Hong Kong offices to investigate the potential of integrating the SBEM. A simulation was used to evaluate the dynamic performance of the energy and air conditioning system with the integration of the SBEM in an air-conditioned building. It allows us make a clear picture of the control strategies and performed any pre-tuned of controllers before utilized in real systems. With the integration of SBEM, it was able to save up to 12.3% in simulation of overall electricity consumption, and maintain the average carbon dioxide concentration within 1000ppm and occupant dissatisfaction in 20%.
Abstract: Based on an indoor environmental quality (IEQ) index established by previous work that indicates the overall IEQ acceptance from the prospect of an occupant in residential buildings in terms of four IEQ factors - thermal comfort, indoor air quality, visual and aural comforts, this study develops a user-friendly IEQ calculator for iOS and Android users to calculate the occupant acceptance and compare the relative performance of IEQ in apartments. “IEQ calculator” is easy to use and it preliminarily illustrates the overall indoor environmental quality on the spot. Users simply input indoor parameters such as temperature, number of people and windows are opened or closed for the mobile application to calculate the scores in four areas: the comforts of temperature, brightness, noise and indoor air quality. The calculator allows the prediction of the best IEQ scenario on a quantitative scale. Any indoor environments under the specific IEQ conditions can be benchmarked against the predicted IEQ acceptance range. This calculator can also suggest how to achieve the best IEQ acceptance among a group of residents.
Abstract: In this paper, we propose a system for preventing gas
risks through the use of wireless communication modules and
intelligent gas safety appliances. Our system configuration consists of
an automatic extinguishing system, detectors, a wall-pad, and a
microcomputer controlled micom gas meter to monitor gas flow and
pressure as well as the occurrence of earthquakes. The automatic fire
extinguishing system checks for both combustible gaseous leaks and
monitors the environmental temperature, while the detector array
measures smoke and CO gas concentrations. Depending on detected
conditions, the micom gas meter cuts off an inner valve and generates
a warning, the automatic fire-extinguishing system cuts off an external
valve and sprays extinguishing materials, or the sensors generate
signals and take further action when smoke or CO are detected.
Information on intelligent measures taken by the gas safety appliances
and sensors are transmitted to the wall-pad, which in turn relays this as
real time data to a server that can be monitored via an external network
(BcN) connection to a web or mobile application for the management
of gas safety. To validate this smart-home gas management system, we
field-tested its suitability for use in Korean apartments under several
scenarios.
Abstract: Prosperity of electronic equipment in photocopying
environment not only has improved work efficiency, but also has
changed indoor air quality. Considering the number of photocopying
employed, indoor air quality might be worse than in general office
environments. Determining the contribution from any type of
equipment to indoor air pollution is a complex matter. Non-methane
hydrocarbons are known to have an important role on air quality due
to their high reactivity. The presence of hazardous pollutants in
indoor air has been detected in one photocopying shop in Novi Sad,
Serbia. Air samples were collected and analyzed for five days, during
8-hr working time in three time intervals, whereas three different
sampling points were determined. Using multiple linear regression
model and software package STATISTICA 10 the concentrations of
occupational hazards and microclimates parameters were mutually
correlated. Based on the obtained multiple coefficients of
determination (0.3751, 0.2389 and 0.1975), a weak positive
correlation between the observed variables was determined. Small
values of parameter F indicated that there was no statistically
significant difference between the concentration levels of nonmethane
hydrocarbons and microclimates parameters. The results
showed that variable could be presented by the general regression
model: y = b0 + b1xi1+ b2xi2. Obtained regression equations allow to
measure the quantitative agreement between the variables and thus
obtain more accurate knowledge of their mutual relations.