Abstract: Power transformers are among the most important and
expensive equipments in the electric power systems. Consequently
the transformer protection is an essential part of the system
protection. This paper presents a new method for locating
transformer winding faults such as turn-to-turn, turn-to-core, turn-totransformer
body, turn-to-earth, and high voltage winding to low
voltage winding. In this study the current and voltage signals of input
and output terminals of the transformer are measured, which the
Fourier transform of measured signals and harmonic analysis
determine the fault's location.
Abstract: Using strength Pulse Electrical Field (PEF) in food
industries is a non-thermal process that can deactivate
microorganisms and increase penetration in plant and animals tissues
without serious impact on food taste and quality. In this paper designing and fabricating of a PEF generator has been presented. Pulse generation methods have been surveyed and the best of them
selected. The equipment by controller set can generate square pulse with adjustable parameters such as amplitude 1-5kV, frequency 0.1-10Hz, pulse width 10-100s, and duty cycle 0-100%. Setting the number of pulses, and presenting the output voltage and current
waveforms on the oscilloscope screen are another advantages of this
equipment. Finally, some food samples were tested that yielded the satisfactory results. PEF applying had considerable effects on potato, banana and purple cabbage. It caused increase Brix factor from 0.05
to 0.15 in potato solution. It is also so effective in extraction color material from purple cabbage. In the last experiment effects of PEF
voltages on color extraction of saffron scum were surveyed (about 6% increasing yield).
Abstract: The use of synthetic retardants in polymeric insulated
cables is not uncommon in the high voltage engineering to study
electrical treeing phenomenon. However few studies on organic
materials for the same investigation have been carried. .This paper
describes the study on the effects of Oil Palm Empty Fruit Bunch
(OPEFB) microfiller on the tree initiation and propagation in silicone
rubber with different weight percentages (wt %) of filler to insulation
bulk material. The weight percentages used were 0 wt % and 1 wt %
respectively. It was found that the OPEFB retards the propagation of
the electrical treeing development. For tree inception study, the
addition of 1(wt %) OPEFB has increase the tree inception voltage of
silicone rubber. So, OPEFB is a potential retardant to the initiation
and growth of electrical treeing occurring in polymeric materials for
high voltage application. However more studies on the effects of
physical and electrical properties of OPEFB as a tree retardant
material are required.
Abstract: When a high DC voltage is applied to a capacitor with
strongly asymmetrical electrodes, it generates a mechanical force that
affects the whole capacitor. This phenomenon is most likely to be
caused by the motion of ions generated around the smaller of the two
electrodes and their subsequent interaction with the surrounding
medium. A method to measure this force has been devised and used.
A formula describing the force has also been derived. After
comparing the data gained through experiments with those acquired
using the theoretical formula, a difference was found above a certain
value of current. This paper also gives reasons for this difference.
Abstract: Performing High Voltage (HV) tasks with a multi craft
work force create a special set of safety circumstances. This paper
aims to present vital information relating to when it is acceptable to
use a single or a two-layer soil structure. Also it discusses the
implication of the high voltage infrastructure on the earth grid and the
safety of this implication under a single or a two-layer soil structure.
A multiple case study is investigated to show the importance of using
the right soil resistivity structure during the earthing system design.
Abstract: The High Voltage (HV) transmission mains into the community necessitate earthing design to ensure safety compliance of the system. Concrete poles are widely used within HV transmission mains; which could have an impact on the earth grid impedance and input impedance of the system from the fault point of view. This paper provides information on concrete pole earthing to enhance the split factor of the system; further, it discusses the deployment of concrete structures in high soil resistivity area to reduce the earth grid system of the plant. This paper introduces the cut off soil resistivity SC ρ when replacing timber poles with concrete ones.
Abstract: High voltage generators are being subject to higher
voltage rating and are being designed to operate in harsh conditions.
Stator windings are the main component of generators in which
Electrical, magnetical and thermal stresses remain major failures for
insulation degradation accelerated aging. A large number of
generators failed due to stator winding problems, mainly insulation
deterioration. Insulation degradation assessment plays vital role in the
asset life management. Mostly the stator failure is catastrophic
causing significant damage to the plant. Other than generation loss,
stator failure involves heavy repair or replacement cost. Electro
thermal analysis is the main characteristic for improvement design of
stator slot-s insulation. Dielectric parameters such as insulation
thickness, spacing, material types, geometry of winding and slot are
major design consideration. A very powerful method available to
analyze electro thermal performance is Finite Element Method
(FEM) which is used in this paper. The analysis of various stator coil
and slot configurations are used to design the better dielectric system
to reduce electrical and thermal stresses in order to increase the
power of generator in the same volume of core. This paper describes
the process used to perform classical design and improvement
analysis of stator slot-s insulation.
Abstract: Charging and discharging phenomenon on the surface
of materials can be found in plasma display panel, spacecraft
charging, high voltage insulator, etc. This report gives a simple
explanation on this phenomenon. A scanning electron microscope
was used not only as a tool to produce energetic electron beam to
charge an insulator without metallic coating and to produce a surface
discharging (surface breakdown/flashover) but also to observe the
visible charging and discharging on the sample surface. A model of
electric field distribution on the surface was developed in order to
explain charging and discharging phenomena. Since charging and
discharging process involves incubation time, therefore this process
can be used to evaluate the insulation property of materials under
electron bombardment.
Abstract: In the present work, Pulsed Electro Acoustic (PEA)
technique was adopted to understand the space charge dynamics in
elastomeric material. It is observed that the polarity of the applied
DC voltage voltage and its magnitude alters the space charge
dynamics in insulation structure. It is also noticed that any addition
of compound to the base material/processing technique have
characteristic variation in the space charge injection process. It could
be concluded based on the present work that the plasticizer could
inject heterocharges into the insulation medium. Also it is realized
that space charge magnitude is less with the addition of plasticizer. In
the PEA studies, it is observed that local electric field in the
insulating material can be much more than applied electric field due
to space charge formation. One of the important conclusions arrived
at based on PEA technique is that one could understand the safe
operating electric field of an insulation material and the charge trap
sites.
Abstract: When a lightning strike falls near an overhead power
line, the intense electromagnetic field radiated by the current of the
lightning return stroke coupled with power lines and there induced
transient overvoltages, which can cause a back-flashover in electrical
network. The indirect lightning represents a major danger owing to
the fact that it is more frequent than that which results from the direct
strikes.
In this paper we present an analysis of the electromagnetic
coupling between an external electromagnetic field generated by the
lightning and an electrical overhead lines, so we give an important
and original contribution: We are based on our experimental
measurements which we carried in the high voltage laboratories of
EPFL in Switzerland during the last trimester of 2005, on the recent
works of other authors and with our mathematical improvement a
new particular analytical expression of the electromagnetic field
generated by the lightning return stroke was developed and presented
in this paper. The results obtained by this new electromagnetic field
formulation were compared with experimental results and give a
reasonable approach.
Abstract: Laboratory classes in Electrical Engineering are often hampered by safety issues, as students have to work on high voltage lines. One solution is to make use of virtual laboratory simulations, to help students understand the concepts taught in their coursework. In this context, we have conceived and implemented virtual lab experiments in connection with the study of earthing arrangements. In this work, software was developed, which aid student in understanding the working of a residual current device (RCD) in a TT earthing system. Various parameters, such as the earthing resistances, leakage currents and harmonics were included for a TT system with RCD connection.
Abstract: Three similar negative differential resistance (NDR)
profiles with both high peak to valley current density ratio (PVCDR)
value and high peak current density (PCD) value in unity resonant
tunneling electronic circuit (RTEC) element is developed in this paper.
The PCD values and valley current density (VCD) values of the three
NDR curves are all about 3.5 A and 0.8 A, respectively. All PV values
of NDR curves are 0.40 V, 0.82 V, and 1.35 V, respectively. The VV
values are 0.61 V, 1.07 V, and 1.69 V, respectively. All PVCDR
values reach about 4.4 in three NDR curves. The PCD value of 3.5 A
in triple PVCDR RTEC element is better than other resonant
tunneling devices (RTD) elements. The high PVCDR value is
concluded the lower VCD value about 0.8 A. The low VCD value is
achieved by suitable selection of resistors in triple PVCDR RTEC
element. The low PV value less than 1.35 V possesses low power
dispersion in triple PVCDR RTEC element. The designed multiple
value logical level (MVLL) system using triple PVCDR RTEC
element provides equidistant logical level. The logical levels of
MVLL system are about 0.2 V, 0.8 V, 1.5 V, and 2.2 V from low
voltage to high voltage and then 2.2 V, 1.3 V, 0.8 V, and 0.2 V from
high voltage back to low voltage in half cycle of sinusoid wave. The
output level of four levels MVLL system is represented in 0.3 V, 1.1 V,
1.7 V, and 2.6 V, which satisfies the NMP condition of traditional
two-bit system. The remarkable logical characteristic of improved
MVLL system with paralleled capacitor are with four significant
stable logical levels about 220 mV, 223 mV, 228 mV, and 230 mV.
The stability and articulation of logical levels of improved MVLL
system are outstanding. The average holding time of improved MVLL
system is approximately 0.14 μs. The holding time of improved
MVLL system is fourfold than of basic MVLL system. The function of
additional capacitor in the improved MVLL system is successfully
discovered.
Abstract: This paper presents development of an ignition system using spark electrodes for application in a research explosion vessel.
A single spark is aimed to be discharged with quantifiable ignition energy. The spark electrode system would enable study of flame
propagation, ignitability of fuel-air mixtures and other fundamental characteristics of flames. The principle of the capacitive spark circuit
of ASTM is studied to charge an appropriate capacitance connected across the spark gap through a large resistor by a high voltage from
the source of power supply until the initiation of spark. Different spark energies could be obtained mainly by varying the value of the
capacitance and the supply current. The spark sizes produced are found to be affected by the spark gap, electrode size, input voltage
and capacitance value.
Abstract: Measurements of capacitance C and dissipation
factor tand of the stator insulation system provide useful information
about internal defects within the insulation. The index k is defined as
the proportionality constant between the changes at high voltage of
capacitance DC and of the dissipation factor Dtand . DC and
Dtand values were highly correlated when small flat defects were
within the insulation and that correlation was lost in the presence of
large narrow defects like electrical treeing. The discrimination
between small and large defects is made resorting to partial discharge
PD phase angle analysis. For the validation of the results, C and tand
measurements were carried out in a 15MVA 4160V steam turbine
turbogenerator placed in a sugar mill. In addition, laboratory test
results obtained by other authors were analyzed jointly. In such
laboratory tests, model coil bars subjected to thermal cycling resulted
highly degraded and DC and Dtand values were not correlated. Thus,
the index k could not be calculated.
Abstract: As known, the guard wires of overhead high voltage
are usually grounded through the grounding systems of support and
of the terminal stations. They do affect the zero sequence impedance
value of the line, Z0, which is generally, calculated assuming that the
wires guard are at ground potential. In this way it is not considered
the effect of the resistances of earth of supports and stations. In this
work is formed a formula for the calculation of Z0 which takes
account of said resistances. Is also proposed a method of calculating
the impedance zero sequence overhead lines in which, in various
sections or spans, the guard wires are connected to the supports, or
isolated from them, or are absent. Parametric analysis is given for
lines 220 kV and 400 kV, which shows the extent of the errors made
with traditional methods of calculation.
Abstract: The demand on High voltage (HV) infrastructures is growing due to the corresponding growth in industries and population. New or upgraded HV infrastructure has safety implications since Transmission mains usually occupy the same easement in the vicinity of neighbouring residents. Transmission mains consist of underground (UG) and overhead (OH) sections and the transition between the UG and OH section is known as the UGOH pole. The existence of two transmission mains in the same easement can dictate to resort to more complicated earthing design in order to mitigate the effect of AC interference, and in some cases it can also necessitates completing a Split Study of the system. This paper provides an overview of the AC interference, Split Study and the earthing of an underground feeder including the UGOH pole .In addition, this paper discusses the use of different link boxes on the UG feeder and presents a case study that represent a clear example of the Ac interference and Split factor. Finally, a few recommendations are provided to achieve a safety zone in the area beyond the boundary of the HV system.
Abstract: This research aimed to develop plasma system used in air conditioners. This developed plasma system could be installed in the air conditioners - all split type. The quality of air could be improved to be equal to present plasma system. Development processes were as follows: 1) to study the plasma system used in the air conditioners, 2) to design a plasma generator, 3) to develop the plasma generator, and 4) to test its performance in many types of the air conditioners. This plasma system was developed by AC high voltage – 14 kv with a frequency of 50 kHz. Carbon was a conductor to generate arc in air purifier system. The research was tested by installing the plasma generator in the air conditioners - wall type. Whereas, there were 3 types of installations: air flow out, air flow in, and room center. The result of the plasma generator installed in the air conditioners, split type, revealed that the air flow out installation provided the highest average of o-zone at 223 mg/h. This type of installation provided the highest efficiency of air quality improvement. Moreover, the air flow in installation and the room center installation provided the average of the o-zone at 163 mg/h and 64 mg/h, respectively.
Abstract: This paper proposes a set of quasi-static mathematical
model of magnetic fields caused by high voltage conductors of
distribution transformer by using a set of second-order partial
differential equation. The modification for complex magnetic field
analysis and time-harmonic simulation are also utilized. In this
research, transformers were study in both balanced and unbalanced
loading conditions. Computer-based simulation utilizing the threedimensional
finite element method (3-D FEM) is exploited as a tool
for visualizing magnetic fields distribution volume a distribution
transformer. Finite Element Method (FEM) is one among popular
numerical methods that is able to handle problem complexity in
various forms. At present, the FEM has been widely applied in most
engineering fields. Even for problems of magnetic field distribution,
the FEM is able to estimate solutions of Maxwell-s equations
governing the power transmission systems. The computer simulation
based on the use of the FEM has been developed in MATLAB
programming environment.
Abstract: This paper presents the development of an electricity simulation model taking into account electrical network constraints, applied on the Belgian power system. The base of the model is optimizing an extensive Unit Commitment (UC) problem through the use of Mixed Integer Linear Programming (MILP). Electrical constraints are incorporated through the implementation of a DC load flow. The model encloses the Belgian power system in a 220 – 380 kV high voltage network (i.e., 93 power plants and 106 nodes). The model features the use of pumping storage facilities as well as the inclusion of spinning reserves in a single optimization process. Solution times of the model stay below reasonable values.
Abstract: In this paper we present a new multichannel high
voltage driver box to connect up to six MOEMS mirror devices to it that have resonant and also quasistatically driven actuating electrodes. It is possible to drive all resonant axes synchronously
while the amplitude of them can individually be controlled by separate microcontrollers that also operate the quasistatic axes.
Circuit simulations are compared with the measurements done on the
real system and also show the robust driving performance of a
MOEMS mirror.