Abstract: Upgrading the thermal performance of building
envelope of existing residential buildings is an effective way to reduce
heat gain or heat loss. Overhang device is a common solution for
building envelope improvement as it can cut down solar heat gain and
thereby can reduce the energy used for space cooling in summer time.
Despite that, overhang can increase the demand for indoor heating in
winter due to its function of lowering the solar heat gain. Obviously,
overhang has different impacts on energy use in different climatic
zones which have different energy demand. To evaluate the impact of
overhang device on building energy performance under different
climates of China, an energy analysis model is built up in a
computer-based simulation program known as DesignBuilder based
on the data of a typical high-rise residential building. The energy
simulation results show that single overhang is able to cut down
around 5% of the energy consumption of the case building in the
stand-alone situation or about 2% when the building is surrounded by
other buildings in regions which predominantly rely on space cooling
though it has no contribution to energy reduction in cold region. In
regions with cold summer and cold winter, adding overhang over
windows can cut down around 4% and 1.8% energy use with and
without adjoining buildings, respectively. The results indicate that
overhang might not an effective shading device to reduce the energy
consumption in the mixed climate or cold regions.
Abstract: So much energy is used in high rise buildings to fulfill
the basic needs of users such as lighting and thermal comfort.
Malaysia has hot and humid climate, buildings especially high rise
buildings receive unnecessary solar radiation that cause more solar
heat gain. Energy use specially electricity consumption in high rise
buildings has increased. There have been growing concerns about
energy consumption and its effect on environment. Building, energy
and the environment are important issues that the designers should
consider to them. Self protected form is one of possible ways against
the impact of solar radiation in high rise buildings. The Energy
performance of building envelopes was investigated in term of the
Overall Thermal Transfer Value (OTTV ).In this paper, the amount
of OTTV reduction was calculated through OTTV Equations to
clear the effectiveness of self shading strategy on minimizing energy
consumption for cooling interior spaces in high rise buildings which
has considerable envelope areas against solar radiation. Also increasing
the optimum window area was investigated using self-shading
strategy in designing high rise buildings. As result, the significant
reduction in OTTV was shown based on WWR.In addition slight
increase was demonstrated in WWR that can influence on visible
comfort interior spaces.
Abstract: Over half of the total electricity consumption is used in buildings. Air-conditioning and electric lighting are the two main resources of electricity consumption in high rise buildings. One way to reduce electricity consumption would be to limit heat gain into buildings, therefore reduce the demand for air-conditioning during hot summer months especially in hot regions. On the other hand natural daylight can be used to reduce the use of electricity for artificial lighting. In this paper effective factors on minimizing heat gain and achieving required day light were reviewed .As daylight always accompanied by solar heat gain. Also interactions between heat gain and daylight were discussed through previous studies and equations which are related to heat gain and day lighting especially in high rise buildings. As a result importance of building-s form and its component on energy consumption in buildings were clarified.
Abstract: Air conditioning is mainly use as human comfort
cooling medium. It use more in high temperatures are country such as
Malaysia. Proper estimation of cooling load will archive ideal
temperature. Without proper estimation can lead to over estimation or
under estimation. The ideal temperature should be comfort enough.
This study is to develop a program to calculate an ideal cooling load
demand, which is match with heat gain. Through this study, it is easy
to calculate cooling load estimation. Objective of this study are to
develop user-friendly and easy excess cooling load program. This is
to insure the cooling load can be estimate by any of the individual
rather than them using rule-of-thumb. Developed software is carryout
by using Matlab-GUI. These developments are only valid for
common building in Malaysia only. An office building was select as
case study to verify the applicable and accuracy of develop software.
In conclusion, the main objective has successfully where developed
software is user friendly and easily to estimate cooling load demand.