Abstract: Acoustic properties of polymeric liquids are high
sensitive to free gas traces in the form of fine bubbles. Their presence
is typical for such liquids because of chemical reactions, small
wettability of solid boundaries, trapping of air in technological
operations, etc. Liquid temperature influences essentially its
rheological properties, which may have an impact on the bubble
pulsations and sound propagation in the system. The target of the
paper is modeling of the liquid temperature effect on single bubble
dynamics and sound dispersion and attenuation in polymeric solution
with spherical gas bubbles. The basic sources of attenuation (heat
exchange between gas in microbubbles and surrounding liquid,
rheological and acoustic losses) are taken into account. It is supposed
that in the studied temperature range the interface mass transfer has a
minor effect on bubble dynamics. The results of the study indicate
that temperature raise yields enhancement of bubble pulsations and
increase in sound attenuation in the near-resonance range and may
have a strong impact on sound dispersion in the liquid-bubble
mixture at frequencies close to the resonance frequency of bubbles.
Abstract: Haynes 25 alloy (also known as L-605 alloy) is cobalt
based super alloy which has widely applications such as aerospace
industry, turbine and furnace parts, power generators and heat
exchangers and petroleum refining components due to its excellent
characteristics. However, the workability of this alloy is more
difficult compared to normal steels or even stainless. In present work,
an experimental investigation was performed under cryogenic
cooling to determine cutting tool wear patterns and obtain optimal
cutting parameters in turning of cobalt based superalloy Haynes 25.
In experiments, uncoated carbide tool was used and cutting speed (V)
and feed rate (f) were considered as test parameters. Tool wear
(VBmax) were measured for process performance indicators.
Analysis of variance (ANOVA) was performed to determine the
importance of machining parameters.
Abstract: This paper carries out a performance analysis based on
the first and second laws of thermodynamics for heat recovery vapor
generator (HRVG) of ammonia-water mixture when the heat source is
low-temperature energy in the form of sensible heat. In the analysis,
effects of the ammonia mass concentration and mass flow ratio of the
binary mixture are investigated on the system performance including
the effectiveness of heat transfer, entropy generation, and exergy
efficiency. The results show that the ammonia concentration and the
mass flow ratio of the mixture have significant effects on the system
performance of HRVG.
Abstract: Carbon steel is used in boilers, pressure vessels, heat
exchangers, piping, structural elements and other moderatetemperature
service systems in which good strength and ductility are
desired. ASME Boiler and Pressure Vessel Code, Section II Part A
(2004) provides specifications of ferrous materials for construction of
pressure equipment, covering wide range of mechanical properties
including high strength materials for power plants application.
However, increased level of springback is one of the major problems
in fabricating components of high strength steel using bending.
Presented work discuss the springback simulations for five different
steels (i.e. SA-36, SA-299, SA-515 grade 70, SA-612 and SA-724
grade B) using finite element analysis of air V-bending. Analytical
springback simulations of hypothetical layered materials are
presented. Result shows that; (i) combination of the material property
parameters controls the springback, (ii) layer of the high ductility
steel on the high strength steel greatly suppresses the springback.
Abstract: The previous researches focused on the influence of
anthropogenic greenhouse gases exerting global warming, but not
consider whether desert sand may warm the planet, this could be
improved by accounting for sand's physical and geometric properties.
Here we show, sand particles (because of their geometry) at the desert
surface form an extended surface of up to 1 + π/4 times the planar area
of the desert that can contact sunlight, and at shallow depths of the
desert form another extended surface of at least 1 + π times the planar
area that can contact air. Based on this feature, an enhanced heat
exchange system between sunlight, desert sand, and air in the spaces
between sand particles could be built up automatically, which can
increase capture of solar energy, leading to rapid heating of the sand
particles, and then the heating of sand particles will dramatically heat
the air between sand particles. The thermodynamics of deserts may
thus have contributed to global warming, especially significant to
future global warming if the current desertification continues to
expand.
Abstract: The cables in a nuclear power plant are designed to be
used for about 40 years in safe operation environment. However, the
heat and radiation in the nuclear power plant causes the rapid
performance deterioration of cables in nuclear vessels and heat
exchangers, which requires cable lifetime estimation. The most
accurate method of estimating the cable lifetime is to evaluate the
cables in a laboratory. However, removing cables while the plant is
operating is not allowed because of its safety and cost. In this paper, a
robot system to estimate the cable lifetime in nuclear power plants is
developed and tested. The developed robot system can calculate a
modulus value to estimate the cable lifetime even when the nuclear
power plant is in operation.
Abstract: The experimental thermal performance of two heat
exchangers in closed-wet cooling tower (CWCT) was investigated in
this study. The test sections are heat exchangers which have multi path
that is used as the entrance of cooling water and are consisting of
bare-type copper tubes between 15.88mm and 19.05mm. The process
fluids are the cooling water that flows from top part of heat exchanger
to bottom side in the inner side of tube, and spray water that flows
gravitational direction in the outer side of it. Air contacts its outer side
of that as it counterflows. Heat and mass transfer coefficients and
cooling capacity were calculated with variations of process fluids,
multi path and different diameter tubes to figure out the performance
of characteristics of CWCT.
The main results were summarized as follows: The results show this
experiment is reliable with values of heat and mass transfer
coefficients comparing to values of correlations. Heat and mass
transfer coefficients and cooling capacity of two paths are higher than
these with one path using 15.88 and 19.05mm tubes. Cooling capacity
per unit volume with 15.88mm tube using one and two paths are
higher than 19.05mm tube due to increase of surface area per unit
volume.
Abstract: Three dimensional simulations in tube in tube heat
exchangers are investigated numerically in this study. In these
simulations forced convective heat transfer and laminar flow of
single-phase water are considered. In order to measure heat transfer
parameters in these heat exchangers, FLUENT CFD Solver is used in
this numerical method. For the purpose of creating geometry and
exert boundary and initial conditions in the present model, finite
volume method in Computational Fluid Dynamics is used in this
study. In the present study, at each Z-location, variation of local
temperatures, heat flux and Nusselt number at the whole tube is
investigated in detail. Thereafter, averaged computational Nusselt
number in this model is calculated. In addition, conceivable pressure
drops have been obtained at each Z-location in this model. Then,
pressure drop values in the present model are explored. Finally, all
the numerical results for this kind of heat exchanger will be discussed
precisely.
Abstract: Evaporator is an important and widely used heat
exchanger in air conditioning and refrigeration industries. Different
methods have been used by investigators to increase the heat transfer
rates in evaporators. One of the passive techniques to enhance heat
transfer coefficient is the application of microfin tubes. The
mechanism of heat transfer augmentation in microfin tubes is
dependent on the flow regime of two-phase flow. Therefore many
investigations of the flow patterns for in-tube evaporation have been
reported in literatures. The gravitational force, surface tension and
the vapor-liquid interfacial shear stress are known as three dominant
factors controlling the vapor and liquid distribution inside the tube. A
review of the existing literature reveals that the previous
investigations were concerned with the two-phase flow pattern for
flow boiling in horizontal tubes [12], [9]. Therefore, the objective of
the present investigation is to obtain information about the two-phase
flow patterns for evaporation of R-134a inside horizontal smooth and
microfin tubes. Also Investigation of heat transfer during flow
boiling of R-134a inside horizontal microfin and smooth tube have
been carried out experimentally The heat transfer coefficients for
annular flow in the smooth tube is shown to agree well with Gungor
and Winterton-s correlation [4]. All the flow patterns occurred in the
test can be divided into three dominant regimes, i.e., stratified-wavy
flow, wavy-annular flow and annular flow. Experimental data are
plotted in two kinds of flow maps, i.e., Weber number for the vapor
versus weber number for the liquid flow map and mass flux versus
vapor quality flow map. The transition from wavy-annular flow to
annular or stratified-wavy flow is identified in the flow maps.
Abstract: This study experimentally and numerically investigates
motor cooling performance. The motor consists of a centrifugal fan,
two axial fans, a shaft, a stator, a rotor and a heat exchanger with 637
cooling tubes. The pressure rise-flow rate (P-Q) performance curves of
the cooling fans at 1800 rpm are tested using a test apparatus
complying with the Chinese National Standard (CNS) 2726.
Compared with the experimental measurements, the numerical
analysis results show that the P-Q performance curves of the axial fan
and centrifugal fan can be estimated within about 2% and 6%,
respectively. By using the simplified model, setting up the heat
exchanger and stator as porous media, the flow field in the motor is
calculated. By using the results of the flow field near the rotor and
stator, and subjecting the heat generation rate as a boundary condition,
the temperature distributions of the stator and rotor are also calculated.
The simulation results show that the calculated temperature of the
stator winding near the axial fans is lower by about 5% than the
measured value, and the calculated temperature of the stator core
located at the center of the stator is about 1% higher than the measured
value. Besides, discussion is made to improve the motor cooling
performance.
Abstract: A co-generation system in automobile can improve
thermal efficiency of vehicle in some degree. The waste heat from the
engine exhaust and coolant is still attractive energy source that reaches
around 60% of the total energy converted from fuel. To maximize the
effectiveness of heat exchangers for recovering the waste heat, it is
vital to select the most suitable working fluid for the system, not to
mention that it is important to find the optimum design for the heat
exchangers. The design of heat exchanger is out of scoop of this study;
rather, the main focus has been on the right selection of working fluid
for the co-generation system. Simulation study was carried out to find
the most suitable working fluid that can allow the system to achieve
the optimum efficiency in terms of the heat recovery rate and thermal
efficiency.
Abstract: The present work deals with thermodynamic analysis
of cascade refrigeration system using ozone friendly refrigerants pair
R507A and R23. R507A is azeotropic mixture composed of HFC
refrigerants R125/R143a (50%/50% wt.). R23 is a single component
HFC refrigerant used as replacement to CFC refrigerant R13 in low
temperature applications. These refrigerants have zero ozone
depletion potential and are non-flammable and as R507A an
azeotropic mixture there is no problem of temperature glide. This
study thermodynamically analyzed R507A-R23 cascade refrigeration
system to optimize the design and operating parameters of the
system. The design and operating parameters include: Condensing,
evaporating, subcooling and superheating temperatures in the high
temperature circuit, temperature difference in the cascade heat
exchanger, Condensing, evaporating, subcooling and superheating
temperatures in the low temperature circuit.