Abstract: The increase in electric power demand in face of
environmental issues has intensified the participation of renewable
energy sources such as photovoltaics, in the energy matrix of various
countries. Due to their operational characteristics, they can generate
time-varying harmonic and inter-harmonic distortions. For this
reason, the application of methods of measurement based on
traditional Fourier analysis, as proposed by IEC 61000-4-7, can
provide inaccurate results. Considering the aspects mentioned herein,
came the idea of the development of this work which aims to present
the results of a comparative evaluation between a methodology
arising from the combination of the Prony method with the Kalman
filter and another method based on the IEC 61000-4-30 and IEC
61000-4-7 standards. Employed in this study were synthetic signals
and data acquired through measurements in a 50kWp photovoltaic
installation.
Abstract: Fresh water is one of the resources which is getting
depleted day by day. A wise method to address this issue is by the
application of renewable energy-sun irradiation and by means of
decentralized, cheap, energetically self-sufficient, robust and simple
to operate plants, distillates can be obtained from sea, river or even
sewage. Solar desalination is a technique used to desalinate water
using solar energy. The present work deals with the comprehensive
design and simulation of solar tracking system using LabVIEW,
temperature and mass flow rate control of the solar desalination plant
using LabVIEW and also analysis of single phase inverter circuit
with LC filters for solar pumping system in MATLAB. The main
objective of this work is to improve the performance of solar
desalination system using automatic tracking system, output control
using temperature and mass flow rate control system and also to
reduce the harmonic distortion in the solar pumping system by means
of LC filters. The simulation of single phase inverter was carried out
using MATLAB and the output waveforms were analyzed.
Simulations were performed for optimum output temperature control,
which in turn controls the mass flow rate of water in the thermal
collectors. Solar tracking system was accomplished using LABVIEW
and was tested successfully. The thermal collectors are tracked in
accordance with the sun’s irradiance levels, thereby increasing the
efficiency of the thermal collectors.
Abstract: In this paper, influence of harmonics on medium
voltage distribution system of Bogazici Electricity Distribution Inc.
(BEDAS) which takes place at Istanbul/Turkey is investigated. A ring
network consisting of residential loads is taken into account for this
study. Real system parameters and measurement results are used for
simulations. Also, probable working conditions of the system are
analyzed for 50%, 75%, and 100% loading of transformers with
similar harmonic contents. Results of the study are exhibited the
influence of nonlinear loads on %THDV, P.F. and technical losses of
the medium voltage distribution system.
Abstract: This paper proposed the comparison made between
Multi-Carrier Pulse Width Modulation, Sinusoidal Pulse Width
Modulation and Selective Harmonic Elimination Pulse Width
Modulation technique for minimization of Total Harmonic Distortion
in Cascaded H-Bridge Multi-Level Inverter. In Multicarrier Pulse
Width Modulation method by using Alternate Position of Disposition
scheme for switching pulse generation to Multi-Level Inverter.
Another carrier based approach; Sinusoidal Pulse Width Modulation
method is also implemented to define the switching pulse generation
system in the multi-level inverter. In Selective Harmonic Elimination
method using Genetic Algorithm and Particle Swarm Optimization
algorithm for define the required switching angles to eliminate low
order harmonics from the inverter output voltage waveform and
reduce the total harmonic distortion value. So, the results validate that
the Selective Harmonic Elimination Pulse Width Modulation method
does capably eliminate a great number of precise harmonics and
minimize the Total Harmonic Distortion value in output voltage
waveform in compared with Multi-Carrier Pulse Width Modulation
method, Sinusoidal Pulse Width Modulation method. In this paper,
comparison of simulation results shows that the Selective Harmonic
Elimination method can attain optimal harmonic minimization
solution better than Multi-Carrier Pulse Width Modulation method,
Sinusoidal Pulse Width Modulation method.
Abstract: This article presents two methods for the
compensation of harmonics generated by a nonlinear load. The first is
the classic method P-Q. The second is the controller by modern
method of artificial intelligence specifically fuzzy logic. Both
methods are applied to a shunt Active Power Filter (sAPF) based on a
three-phase voltage converter at five levels NPC topology. In
calculating the harmonic currents of reference, we use the algorithm
P-Q and pulse generation, we use the intersective PWM. For
flexibility and dynamics, we use fuzzy logic. The results give us clear
that the rate of Harmonic Distortion issued by fuzzy logic is better
than P-Q.
Abstract: This paper proposes five level diode clamped Z source
Inverter. The existing PWM techniques used for ZSI are restricted for
two level. The two level Z Source Inverter have high harmonic
distortions which effects the performance of the grid connected PV
system. To improve the performance of the system the number of
voltage levels in the output waveform need to be increased. This
paper presents comparative analysis of a five level diode clamped Z
source Inverter with different carrier based Modified Pulse Width
Modulation techniques. The parameters considered for comparison
are output voltage, voltage gain, voltage stress across switch and total
harmonic distortion when powered by same DC supply. Analytical
results are verified using MATLAB.
Abstract: Multi-Level Inverter technology has been developed in the area of high-power medium-voltage energy scheme, because of their advantages such as devices of lower rating can be used thereby enabling the schemes to be used for high voltage applications. Reduced Total Harmonic Distortion (THD).Since the dv/dt is low; the Electromagnetic Interference from the scheme is low. To avoid the switching losses Lower switching frequencies can be used. In this paper present a survey of various topologies, control strategy and modulation techniques used by these inverters. Here the regenerative and superior topologies are also discussed.
Abstract: This paper presents the simulation results of the
effects of sampling frequency on the total harmonic distortion (THD)
of three-phase inverters using the space vector pulse width
modulation (SVPWM) and space vector control (SVC) algorithms.
The relationship between the variables was studied using curve fitting
techniques, and it has been shown that, for 50 Hz inverters, there is
an exponential relation between the sampling frequency and THD up
to around 8500 Hz, beyond which the performance of the model
becomes irregular, and there is an negative exponential relation
between the sampling frequency and the marginal improvement to
the THD. It has also been found that the performance of SVPWM is
better than that of SVC with the same sampling frequency in most
frequency range, including the range where the performance of the
former is irregular.
Abstract: With advances in solid-state power electronic devices
and microprocessors, various pulse-width-modulation (PWM)
techniques have been developed for industrial applications. This
paper presents the comparison of two different PWM techniques, the
sinusoidal PWM (SPWM) technique and the space-vector PWM
(SVPWM) technique applied to two level VSI for micro grid
applications. These two methods are compared by discussing their
ease of implementation and by analyzing the output harmonic spectra
of various output voltages (line-to-neutral voltages, and line-to-line
voltages) and their total harmonic distortion (THD). The SVPWM
technique in the under-modulation region can increase the
fundamental output voltage by 15.5% over the SPWM technique.
Abstract: In this paper family of multilevel inverter topology
with reduced number of power switches is presented. The proposed
inverter can generate both even and odd level. The proposed topology
is suitable for symmetric structure. The proposed symmetric inverter
results in reduction of power switches, power diode and gate driver
circuits and also it may further minimize the installation area and
cost. To prove the superiority of proposed topology is compared with
conventional topologies. The performance of this symmetric
multilevel inverter has been tested by computer based simulation and
prototype based experimental setup for nine-level inverter is
developed and results are verified.
Abstract: In this paper, we present a comparative assessment of
Space Vector Pulse Width Modulation (SVPWM) and Model
Predictive Control (MPC) for two-level three phase (2L-3P) Voltage
Source Inverter (VSI). VSI with associated system is subjected to
both control techniques and the results are compared.
Matlab/Simulink was used to model, simulate and validate the
control schemes. Findings of this study show that MPC is superior to
SVPWM in terms of total harmonic distortion (THD) and
implementation.
Abstract: This paper presents a hybrid three phase rectifier for
high power factor application. This rectifier is composed by zero
voltage transition (ZVT) and zero current transition (ZCT) boost
converter with three phase diode bridge rectifier, in parallel with a six
pulse three phase pulse width modulation (PWM) controlled rectifier.
The proposed topology is capable of high power factor with DC
output voltage regulation by providing sinusoidal input. Also, it
increases the overall efficiency of the new hybrid rectifier to 94.56%
and the total harmonic distortion of the hybrid structure varies from
0% to 16% at nominal output power. This topology was simulated in
MATLAB/SIMULINK environment and the output waveforms
presented with experimental result.
Abstract: Multilevel inverters such as flying capacitor, diodeclamped,
and cascaded H-bridge inverters are very popular
particularly in medium and high power applications. This paper
focuses on a cascaded H-bridge module using a single direct current
(DC) source in order to generate an 11-level output voltage. The
noble approach reduces the number of switches and gate drivers, in
comparison with a conventional method. The anticipated topology
produces more accurate result with an isolation transformer at high
switching frequency. Different modulation techniques can be used for
the multilevel inverter, but this work features modulation techniques
known as selective harmonic elimination (SHE).This modulation
approach reduces the number of carriers with reduction in Switching
Losses, Total Harmonic Distortion (THD), and thereby increasing
Power Quality (PQ). Based on the simulation result obtained, it
appears SHE has the ability to eliminate selected harmonics by
chopping off the fundamental output component. The performance
evaluation of the proposed cascaded multilevel inverter is performed
using PSIM simulation package and THD of 0.94% is obtained.
Abstract: One of the major power quality concerns in modern times is the problem of current harmonics. The current harmonics is caused due to the increase in non-linear loads which is largely dominated by power electronics devices. The Shunt active filtering is one of the best solutions for mitigating current harmonics. This paper describes a fuzzy logic controller based (FLC) based three Phase Shunt active Filter to achieve low current harmonic distortion (THD) and Reactive power compensation. The performance of fuzzy logic controller is analysed under both balanced sinusoidal and unbalanced sinusoidal source condition. The above controller serves the purpose of maintaining DC Capacitor Voltage constant. The proposed shunt active filter uses hysteresis current controller for current control of IGBT based PWM inverter. The simulation results of model in Simulink MATLAB reveals satisfying results.
Abstract: Multilevel inverter is a promising inverter topology for high voltage and high power applications. This inverter synthesizes several different levels of DC voltages to produce a stepped AC output that approaches the pure sine waveform. The three different topologies, diode-clamped inverter, capacitor-clamped inverter and cascaded h-bridge multilevel inverter are widely used in these multilevel inverters. Among the three topologies, cascaded h-bridge multilevel inverter is more suitable for photovoltaic applications since each PV array can act as a separate dc source for each h-bridge module. This research especially focus on photovoltaic power source as input to the system and shows the potential of a Single Phase Cascaded H-bridge Eleven level inverter governed by the fuzzy logic controller to improve the power quality by reducing the total harmonic distortion at the output voltage. Hence the efficiency of the system will be improved. Simulation using MATLAB/SIMULINK has been done to verify the performance of cascaded h-bridge eleven level inverter using sinusoidal pulse width modulation technique. The simulated output shows very favorable result.
Abstract: Power quality in terms of power factor, THD and precisely regulated output voltage are the major key factors for efficient operation of power electronic converters. This paper presents an easy and effective active wave shaping control scheme for the pulsed input current drawn by the uncontrolled diode bridge rectifier thereby achieving power factor nearer to unity and also satisfying the THD specifications. It also regulates the output DC-bus voltage. CCM boost power factor correction with constant frequency operation features smaller inductor current ripple resulting in low RMS currents on inductor and switch thus leading to low electromagnetic interference. The objective of this work is to develop an active PFC control circuit using CCM boost converter implementing variable duty cycle control. The proposed scheme eliminates inductor current sensing requirements yet offering good performance and satisfactory results for maintaining the power quality. Simulation results have been presented which covers load changes also.
Abstract: This paper is based on the bridgeless single-phase Ac–Dc Power Factor Correction (PFC) converters with Fuzzy Logic Controller. High frequency isolated Cuk converters are used as a modular dc-dc converter in Discontinuous Conduction Mode (DCM) of operation of Power Factor Correction. The aim of this paper is to simplify the program complexity of the controller by reducing the number of fuzzy sets of the Membership Functions (MFs) and to improve the efficiency and to eliminate the power quality problems. The output of Fuzzy controller is compared with High frequency triangular wave to generate PWM gating signals of Cuk converter. The proposed topologies are designed to work in Discontinuous Conduction Mode (DCM) to achieve a unity power factor and low total harmonic distortion of the input current. The Fuzzy Logic Controller gives additional advantages such as accurate result, uncertainty and imprecision and automatic control circuitry. Performance comparisons between the proposed and conventional controllers and circuits are performed based on circuit simulations.
Abstract: Distributed Generation (DG) systems are considered an integral part in future distribution system planning. Appropriate size and location of distributed generation plays a significant role in minimizing power losses in distribution systems. Among the benefits of distributed generation is the reduction in active power losses, which can improve the system performance, reliability and power quality. In this paper, Artificial Bee Colony (ABC) algorithm is proposed to determine the optimal DG-unit size and location by loss sensitivity index in order to minimize the real power loss, total harmonic distortion (THD) and voltage sag index improvement. Simulation study is conducted on 69-bus radial test system to verify the efficacy of the proposed method.
Abstract: The aim of this paper is to identify an optimum
control strategy of three-phase shunt active filters to minimize the total harmonic distortion factor of the supply current. A classical PIPI cascade control solution of the output current of the active filterand the voltage across the DC capacitor based on Modulus–Optimum
criterion is taken into consideration. The control system operation
has been simulated using Matlab-Simulink environment and the results agree with the theoretical expectation. It is shown that there is
an optimum value of the DC-bus voltage which minimizes the supply current harmonic distortion factor. It corresponds to the equality of the apparent power at the output of the active filter and the apparent power across the capacitor. Finally, predicted results are verified experimentally on a MaxSine active power filter.
Abstract: The paper presents a space-vector pulse width modulation (SVPWM) inverter feeding a permanent-magnet synchronous motor (PMSM). The SVPWM inverter enables to feed the motor with a higher voltage with low harmonic distortions than the conventional sinusoidal PWM inverter. The control strategy of the inverter is the voltage / frequency control method, which is based on the space-vector modulation technique. The proposed PMSM drive system involving the field-oriented control scheme not only decouples the torque and flux which provides faster response but also makes the control task easy. The performance of the proposed drive is simulated. The advantages of the proposed drive are confirmed by the simulation results.