Abstract: This paper presents a comparative study of static analysis procedure for seismic performance based on UBC-1997 and SBC-301-2007(Saudi Arabia). These building codes define different ductility classes and corresponding response reduction factors based on material, configuration and detailing of reinforcements. Codes differ significantly in specifying the procedures to estimate base shear, drift and effective stiffness of structural members. One of the major improvements made in new SBC (based on IBC-2003) is ground motion parameters used for seismic design. In old SBC (based on UBC) maps have been based on seismic zones. However new SBC provide contour maps giving spectral response quantities. In this approach, a case study of RC frame building located in two different cities and with different ductility classes has been performed. Moreover, equivalent static method based on SBC-301 and UBC-1997 is used to explore the variation in results based on two codes, particularly design base shear, lateral loads and story drifts.
Abstract: The transmission line towers are one of the important life line structures in the distribution of power from the source to the various places for several purposes. The predominant external loads which act on these towers are wind and earthquake loads. In this present study tower is analyzed using Indian Standards IS: 875:1987(Wind Load), IS: 802:1995(Structural steel), IS:1893:2002 (Earthquake) and dynamic analysis of tower has been performed considering ground motion of 2001 Bhuj Earthquake (India). The dynamic analysis was performed considering a tower system consisting two towers spaced 800m apart and 35m height each. This analysis has been performed using numerical time stepping finite difference method which is central difference method were employed by a developed MATLAB program to get the normalized ground motion parameters includes acceleration, frequency, velocity which are important in designing the tower. The tower is analyzed using response spectrum analysis.
Abstract: Slab sliding system (SSS) with Coulomb friction
interface between slab and supporting frame is a passive structural
vibration control technology. The system can significantly reduce the
slab acceleration and accompanied lateral force of the frame. At the
same time it is expected to cause the slab displacement magnification
by sliding movement. To obtain the general comprehensive seismic
response of a single story structure, inelastic response spectra were
computed for a large ensemble of ground motions and a practical range
of structural periods and friction coefficient values. It was shown that
long period structures have no trade-off relation between force
reduction and displacement magnification with respect to elastic
response, unlike short period structures. For structures with the
majority of mass in the slab, the displacement magnification value can
be predicted according to simple inelastic displacement relation for
inelastically responding SDOF structures because the system behaves
elastically to a SDOF structure.
Abstract: A failure of the non-structural component can cause significant damages in critical facilities such as nuclear power plants and hospitals. Historically, it was reported that the damage from the leakage of sprinkler systems, resulted in the shutdown of hospitals for several weeks by the 1971 San Fernando and 1994 North Ridge earthquakes. In most cases, water leakages were observed at the cross joints, sprinkler heads, and T-joint connections in piping systems during and after the seismic events. Hence, the primary objective of this study was to understand the seismic performance of T-joint connections and to develop an analytical Finite Element (FE) model for the T-joint systems of 2-inch fire protection piping system in hospitals subjected to seismic ground motions. In order to evaluate the FE models of the piping systems using OpenSees, two types of materials were used: 1) Steel02 materials and 2) Pinching4 materials. Results of the current study revealed that the nonlinear moment-rotation FE models for the threaded T-joint reconciled well with the experimental results in both FE material models. However, the system-level fragility determined from multiple nonlinear time history analyses at the threaded T-joint was slightly different. The system-level fragility at the T-joint, determined by Pinching4 material was more conservative than that of using Steel02 material in the piping system.
Abstract: Widespread use of response spectra in seismic design and evaluation of different types of structures makes them one of the most important seismic inputs. This importance urges the local design codes to adapt precise data based on updated information about the recent major earthquakes happened and also localized geotechnical data. In this regard, this paper derives the response spectra with a geotechnical approach for various scenarios coming from the recent major earthquakes happened in Iran for different types of hard soils, and compares the results to the corresponding spectra from the current seismic code. This comparison implies the need for adapting new design spectra for seismic design, because of major differences in the frequency domains and amplifications.
Abstract: Superelastic Shape Memory Alloy (SMA) is accepted
when it used as connection in steel structures. The seismic behaviour
of steel frames with SMA is being assessed in this study. Three eightstorey
steel frames with different SMA systems are suggested, the
first one of which is braced with diagonal bracing system, the second
one is braced with nee bracing system while the last one is which the
SMA is used as connection at the plastic hinge regions of beams.
Nonlinear time history analyses of steel frames with SMA subjected
to two different ground motion records have been performed using
Seismostruct software. To evaluate the efficiency of suggested
systems, the dynamic responses of the frames were compared. From
the comparison results, it can be concluded that using SMA element
is an effective way to improve the dynamic response of structures
subjected to earthquake excitations. Implementing the SMA braces
can lead to a reduction in residual roof displacement. The shape
memory alloy is effective in reducing the maximum displacement at
the frame top and it provides a large elastic deformation range. SMA
connections are very effective in dissipating energy and reducing the
total input energy of the whole frame under severe seismic ground
motion. Using of the SMA connection system is more effective in
controlling the reaction forces at the base frame than other bracing
systems. Using SMA as bracing is more effective in reducing the
displacements. The efficiency of SMA is dependant on the input
wave motions and the construction system as well.
Abstract: Excessive ductility demand on shorter piers is a
common problem for irregular bridges subjected to strong ground
motion. Various techniques have been developed to reduce the
likelihood of collapse of bridge due to failure of shorter piers. This
paper presents the new approach to improve the seismic behavior of
such bridges using Nitinol shape memory alloys (SMAs).
Superelastic SMAs have the ability to remain elastic under very large
deformation due to martensitic transformation. This unique property
leads to enhanced performance of controlled bridge compared with
the performance of the reference bridge. To evaluate the effectiveness
of the devices, nonlinear time history analysis is performed on a RC
single column bent highway bridge using a suite of representative
ground motions. The results show that this method is very effective in
limiting the ductility demand of shorter pier.
Abstract: We study the dynamic response of a wind turbine
structure subjected to theoretical seismic motions, taking into account
the rotational component of ground shaking. Models are generated
for a shallow moderate crustal earthquake in the Madrid Region
(Spain). Synthetic translational and rotational time histories are
computed using the Discrete Wavenumber Method, assuming a point
source and a horizontal layered earth structure. These are used to
analyze the dynamic response of a wind turbine, represented by a
simple finite element model. Von Mises stress values at different
heights of the tower are used to study the dynamical structural
response to a set of synthetic ground motion time histories
Abstract: Presented herein is an assessment of current nonlinear
static procedures (NSPs) for seismic evaluation of bucklingrestrained
braced frames (BRBFs) which have become a favorable
lateral-force resisting system for earthquake resistant buildings. The
bias and accuracy of modal, improved modal pushover analysis
(MPA, IMPA) and mass proportional pushover (MPP) procedures
are comparatively investigated when they are applied to BRBF
buildings subjected to two sets of strong ground motions. The
assessment is based on a comparison of seismic displacement
demands such as target roof displacements, peak floor/roof
displacements and inter-story drifts. The NSP estimates are compared
to 'exact' results from nonlinear response history analysis (NLRHA).
The response statistics presented show that the MPP
procedure tends to significantly overestimate seismic demands of
lower stories of tall buildings considered in this study while MPA
and IMPA procedures provide reasonably accurate results in
estimating maximum inter-story drift over all stories of studied BRBF
systems.
Abstract: In the paper the results of calculations of the dynamic
response of a multi-storey reinforced concrete building to a strong
mining shock originated from the main region of mining activity in
Poland (i.e. the Legnica-Glogow Copper District) are presented. The
representative time histories of accelerations registered in three
directions were used as ground motion data in calculations of the
dynamic response of the structure. Two variants of a numerical model
were applied: the model including only structural elements of the
building and the model including both structural and non-structural
elements (i.e. partition walls and ventilation ducts made of brick). It
turned out that non-structural elements of multi-storey RC buildings
have a small impact of about 10 % on natural frequencies of these
structures. It was also proved that the dynamic response of building
to mining shock obtained in case of inclusion of all non-structural
elements in the numerical model is about 20 % smaller than in case
of consideration of structural elements only. The principal stresses
obtained in calculations of dynamic response of multi-storey building
to strong mining shock are situated on the level of about 30% of
values obtained from static analysis (dead load).
Abstract: In this experimental investigation shake table tests
were conducted on two reduced models that represent normal single
room building constructed by Compressed Stabilized Earth Block
(CSEB) from locally available soil. One model was constructed with
earthquake resisting features (EQRF) having sill band, lintel band and
vertical bands to control the building vibration and another one was
without Earthquake Resisting Features. To examine the seismic
capacity of the models particularly when it is subjected to long-period
ground motion by large amplitude by many cycles of repeated
loading, the test specimen was shaken repeatedly until the failure.
The test results from Hi-end Data Acquisition system show that
model with EQRF behave better than without EQRF. This modified
masonry model with new material combined with new bands is used
to improve the behavior of masonry building.
Abstract: A method to predict the column size for displacement based design of reinforced concrete frame buildings with higher target inter storey drift is reported here. The column depth derived from empirical relation as a function of given beam section, target inter-story drift, building plan features and common displacement based design parameters is used. Regarding the high drift requirement, a minimum column-beam moment capacity ratio is maintained during capacity design. The method is used in designing four, eight and twelve story frame buildings with displacement based design for three percent target inter storey drift. Non linear time history analysis of the designed buildings are performed under five artificial ground motions to show that the columns are found elastic enough to avoid column sway mechanism assuring that for the design the column size can be used with or without minor changes.
Abstract: This study examines the inelastic behavior of adjacent planar reinforced concrete (R.C.) frames subjected to strong ground motions. The investigation focuses on the effects of vertical ground motion on the seismic pounding. The examined structures are modeled and analyzed by RUAUMOKO dynamic nonlinear analysis program using reliable hysteretic models for both structural members and contact elements. It is found that the vertical ground motion mildly affects the seismic response of adjacent buildings subjected to structural pounding and, for this reason, it can be ignored from the displacement and interstorey drifts assessment. However, the structural damage is moderately affected by the vertical component of earthquakes.
Abstract: Recordings from recent earthquakes have provided evidence that ground motions in the near field of a rupturing fault differ from ordinary ground motions, as they can contain a large energy, or “directivity" pulse. This pulse can cause considerable damage during an earthquake, especially to structures with natural periods close to those of the pulse. Failures of modern engineered structures observed within the near-fault region in recent earthquakes have revealed the vulnerability of existing RC buildings against pulse-type ground motions. This may be due to the fact that these modern structures had been designed primarily using the design spectra of available standards, which have been developed using stochastic processes with relatively long duration that characterizes more distant ground motions. Many recently designed and constructed buildings may therefore require strengthening in order to perform well when subjected to near-fault ground motions. Fiber Reinforced Polymers are considered to be a viable alternative, due to their relatively easy and quick installation, low life cycle costs and zero maintenance requirements. The objective of this paper is to investigate the adequacy of Artificial Neural Networks (ANN) to determine the three dimensional dynamic response of FRP strengthened RC buildings under the near-fault ground motions. For this purpose, one ANN model is proposed to estimate the base shear force, base bending moments and roof displacement of buildings in two directions. A training set of 168 and a validation set of 21 buildings are produced from FEA analysis results of the dynamic response of RC buildings under the near-fault earthquakes. It is demonstrated that the neural network based approach is highly successful in determining the response.
Abstract: Few studies have been conducted on polymeric strip
and the behavior of soil retaining walls. This paper will present the
effect of frequency on the dynamic behavior of reinforced soil
retaining walls with polymeric strips. The frequency content
describes how the amplitude of a ground motion is distributed among
different frequencies. Since the frequency content of an earthquake
motion will strongly influence the effects of that motion, the
characterization of the motion cannot be completed without the
consideration of its frequency content. The maximum axial force of
reinforcements and horizontal displacement of the reinforced walls
are focused in this research. To clarify the dynamic behavior of
reinforced soil retaining walls with polymeric strips, a numerical
modeling using Finite Difference Method is benefited. As the results
indicate, the frequency of input base acceleration has an important
effect on the behavior of these structures. Because of resonant in the
system, where the frequency of the input dynamic load is equal to the
natural frequency of the system, the maximum horizontal
displacement and the maximum axial forces in polymeric strips is
occurred. Moreover, they were to increase the structure flexibility
because of the main advantages of polymeric strips; i.e. being simple
method of construction, having a homogeneous behavior with soils,
and possessing long durability, which are of great importance in
dynamic analysis.
Abstract: The innovative fuzzy estimator is used to estimate the
ground motion acceleration of the retaining structure in this study. The
Kalman filter without the input term and the fuzzy weighting recursive
least square estimator are two main portions of this method. The
innovation vector can be produced by the Kalman filter, and be
applied to the fuzzy weighting recursive least square estimator to
estimate the acceleration input over time. The excellent performance
of this estimator is demonstrated by comparing it with the use of
difference weighting function, the distinct levels of the measurement
noise covariance and the initial process noise covariance. The
availability and the precision of the proposed method proposed in this
study can be verified by comparing the actual value and the one
obtained by numerical simulation.
Abstract: In the paper a detailed analysis of the dynamic
response of a cooling tower shell to mining tremors originated from
two main regions of mining activity in Poland (Upper Silesian Coal
Basin and Legnica-Glogow Copper District) was presented. The
representative time histories registered in the both regions were used
as ground motion data in calculations of the dynamic response of the
structure. It was proved that the dynamic response of the shell is
strongly dependent not only on the level of vibration amplitudes but
on the dominant frequency range of the mining shock typical for the
mining region as well. Also a vertical component of vibrations
occurred to have considerable influence on the total dynamic
response of the shell. Finally, it turned out that non-uniformity of
kinematic excitation resulting from spatial variety of ground motion
plays a significant role in dynamic analysis of large-dimensional
shells under mining shocks.
Abstract: Probabilistic characteristics of seismic responses of the
Partially Restrained connection rotation (PRCR) and panel zone
deformation (PZD) installed in older steel moment frames were
investigated in accordance with statistical inference in
decision-making process. The 4, 6 and 8 story older steel moment
frames with clip angle and T-stub connections were designed and
analyzed using 2%/50yrs ground motions in four cities of the
Mid-America earthquake region. The probability density function and
cumulative distribution function of PRCR and PZD were determined
by the goodness-of-fit tests based on probabilistic parameters
measured from the results of the nonlinear time-history analyses. The
obtained probabilistic parameters and distributions can be used to find
out what performance level mainly PR connections and panel zones
satisfy and how many PR connections and panel zones experience a
serious damage under the Mid-America ground motions.
Abstract: This paper presents an analytical solution to get a reliable estimation of the hydrodynamic pressure on gravity dams induced by vertical component earthquake when solving the fluid and dam interaction problem. Presented analytical technique is presented for calculation of earthquake-induced hydrodynamic pressure in the reservoir of gravity dams allowing for water compressibility and wave absorption at the reservoir bottom. This new analytical solution can take into account the effect of bottom material on seismic response of gravity dams. It is concluded that because the vertical component of ground motion causes significant hydrodynamic forces in the horizontal direction on a vertical upstream face, responses to the vertical component of ground motion are of special importance in analysis of concrete gravity dams subjected to earthquakes.
Abstract: We study dynamic instability in high-rise steel moment
resisting frames (SMRFs) subjected to synthetic long-period ground
motions caused by hypothetical huge subduction earthquakes. Since
long duration as well as long dominant periods is a characteristic of
long-period ground motions, interstory drifts may enter the negative
postyield stiffness range many times when high-rise buildings are
subjected to long-period ground motions. Through the case studies of
9 high-rise SMRFs designed in accordance with the Japanese design
practice in 1980s, we demonstrate that drifting, or accumulation of
interstory drifts in one direction, occurs at the lower stories of the
SMRFs, if their natural periods are close to the dominant periods of the
long-period ground motions. The drifting led to residual interstory
drift ratio over 0.01, or to collapse if the design base shear was small.