Abstract: Fibre reinforced concrete (FRC) has been widely used in industrial pavements and non-structural elements such as pipes, culverts, tunnels, and precast elements. The strengthening effect of fibres in the concrete matrix is achieved primarily due to the bridging effect of fibres at the crack interfaces. The workability of the concrete was reduced on addition of high percentages of steel fibres. The optimum percentage of addition of steel fibres varies with its aspect ratio. For this study, 1% addition of steel has resulted to be the optimum percentage for both Hooked and Crimped Steel Fibres and was added to the beam specimens. The fibres restrain efficiently the cracks and take up residual stresses beyond the cracking. In this sense, diagonal cracks are effectively stitched up by fibres crossing it. The failure of beams within the shear failure range changed from shear to flexure in the presence of sufficient steel fibre quantity. The shear strength is increased with the addition of steel fibres and had exceeded the enhancement obtained with the transverse reinforcement. However, such increase is not directly in proportion with the quantity of fibres used. Considering all the clarification made in the present experimental investigation, it is concluded that 1% of crimped steel fibres with an aspect ratio of 50 is the best type of steel fibres for replacement of transverse stirrups in high strength concrete beams when compared to the steel fibres with hooked ends.
Abstract: This paper summarizes the results of a survey on
smart non-structural element dynamic dissipation when installed
in modern high-rise mega-frame prototypes. An innovative glazed
curtain wall was designed using Shape Memory Alloy (SMA)
joints in order to increase the energy dissipation and enhance
the seismic/wind response of the structures. The studied buildings
consisted of thirty- and sixty-storey planar frames, extracted from
reference three-dimensional steel Moment Resisting Frame (MRF)
with outriggers and belt trusses. The internal core was composed of
a CBF system, whilst outriggers were placed every fifteen stories
to limit second order effects and inter-storey drifts. These structural
systems were designed in accordance with European rules and
numerical FE models were developed with an open-source code,
able to account for geometric and material nonlinearities. With
regard to the characterization of non-structural building components,
full-scale crescendo tests were performed on aluminium/glass curtain
wall units at the laboratory of the Construction Technologies
Institute (ITC) of the Italian National Research Council (CNR),
deriving force-displacement curves. Three-dimensional brick-based
inelastic FE models were calibrated according to experimental results,
simulating the fac¸ade response. Since recent seismic events and
extreme dynamic wind loads have generated the large occurrence of
non-structural components failure, which causes sensitive economic
losses and represents a hazard for pedestrians safety, a more
dissipative glazed curtain wall was studied. Taking advantage of the
mechanical properties of SMA, advanced smart joints were designed
with the aim to enhance both the dynamic performance of the single
non-structural unit and the global behavior. Thus, three-dimensional
brick-based plastic FE models were produced, based on the innovated
non-structural system, simulating the evolution of mechanical
degradation in aluminium-to-glass and SMA-to-glass connections
when high deformations occurred. Consequently, equivalent nonlinear
links were calibrated to reproduce the behavior of both tested and
smart designed units, and implemented on the thirty- and sixty-storey
structural planar frame FE models. Nonlinear time history analyses
(NLTHAs) were performed to quantify the potential of the new
system, when considered in the lateral resisting frame system (LRFS)
of modern high-rise MRFs. Sensitivity to the structure height was
explored comparing the responses of the two prototypes. Trends
in global and local performance were discussed to show that, if
accurately designed, advanced materials in non-structural elements provide new sources of energy dissipation.
Abstract: Seismic vulnerability assessment of masonry buildings is a fundamental issue even for moderate to low seismic hazard regions. This fact is even more important when dealing with old structures such as those located in Annaba city (Algeria), which the majority of dates back to the French colonial era from 1830. This category of buildings is in high risk due to their highly degradation state, heterogeneous materials and intrusive modifications to structural and non-structural elements. Furthermore, they are usually shelter a dense population, which is exposed to such risk. In order to undertake a suitable seismic risk mitigation strategies and reinforcement process for such structures, it is essential to estimate their seismic resistance capacity at a large scale. In this sense, two seismic vulnerability index methods and damage estimation have been adapted and applied to a pilot-scale building area located in the moderate seismic hazard region of Annaba city: The first one based on the EMS-98 building typologies, and the second one derived from the Italian GNDT approach. To perform this task, the authors took the advantage of an existing data survey previously performed for other purposes. The results obtained from the application of the two methods were integrated and compared using a geographic information system tool (GIS), with the ultimate goal of supporting the city council of Annaba for the implementation of risk mitigation and emergency planning strategies.
Abstract: This paper deals with different modeling aspects of masonry infill: no infill model, Layered shell infill model, and strut infill model. These models consider the complicated behavior of the in-filled plane frames under lateral load similar to an earthquake load. Three strut infill models are used: NBCC (2005) strut infill model, ASCE/SEI 41-06 strut infill model and proposed strut infill model based on modification to Canadian, NBCC (2005) strut infill model. Pushover and modal analyses of a masonry infill concrete frame with a single storey and an existing 5-storey RC building have been carried out by using different models for masonry infill. The corresponding hinge status, the value of base shear at target displacement as well as their dynamic characteristics have been determined and compared. A validation of the structural numerical models for the existing 5-storey RC building has been achieved by comparing the experimentally measured and the analytically estimated natural frequencies and their mode shapes. This study shows that ASCE/SEI 41-06 equation underestimates the values for the equivalent properties of the diagonal strut while Canadian, NBCC (2005) equation gives realistic values for the equivalent properties. The results indicate that both ASCE/SEI 41-06 and Canadian, NBCC (2005) equations for strut infill model give over estimated values for dynamic characteristic of the building. Proposed modification to Canadian, NBCC (2005) equation shows that the fundamental dynamic characteristic values of the building are nearly similar to the corresponding values using layered shell elements as well as measured field results.
Abstract: The present report describes the characteristics of
damages and behavior of reinforced concrete buildings during the
tsunami action. The discussion is based on the field damage survey in
selected cities located on the coast of the zone affected by the Great
East Japan Earthquake on March 11, 2011. This earthquake is the most
powerful know earthquake that has hit Japan with a magnitude 9.0 and
with epicenter located at 129 km of Sendai city (off the coast). The
earthquake triggered a destructive tsunami with run up height of up to
40 meters that mainly affect cities located on the Pacific Ocean coast of
the Tohoku region (north-east region of Japan). Reinforced concrete
buildings in general resist the tsunami without collapse however the
non-structural elements like panels and ceilings were severely
damaged. The analysis of damages has permitted to understand the
behavior of RC buildings under tsunami attack, and has also permitted
to establish recommendations for their use to take refuge from tsunami
in places where natural topography makes impossible to reach hilltops
or other safer places.
Abstract: In the paper the results of calculations of the dynamic
response of a multi-storey reinforced concrete building to a strong
mining shock originated from the main region of mining activity in
Poland (i.e. the Legnica-Glogow Copper District) are presented. The
representative time histories of accelerations registered in three
directions were used as ground motion data in calculations of the
dynamic response of the structure. Two variants of a numerical model
were applied: the model including only structural elements of the
building and the model including both structural and non-structural
elements (i.e. partition walls and ventilation ducts made of brick). It
turned out that non-structural elements of multi-storey RC buildings
have a small impact of about 10 % on natural frequencies of these
structures. It was also proved that the dynamic response of building
to mining shock obtained in case of inclusion of all non-structural
elements in the numerical model is about 20 % smaller than in case
of consideration of structural elements only. The principal stresses
obtained in calculations of dynamic response of multi-storey building
to strong mining shock are situated on the level of about 30% of
values obtained from static analysis (dead load).