Abstract: At present, vibrations of rotors of gas transmittal unit evade sustainable forecasting. This paper describes elastic oscillation modes in resilient supports and rotor impellers modeled during computational experiments with regard to interference in the system of gas-dynamic flow and compressor rotor. Verification of aeroelastic approach was done on model problem of interaction between supersonic jet in shock tube with deformed plate. ANSYS 15.0 engineering analysis system was used as a modeling tool of numerical simulation in this paper. Finite volume method for gas dynamics and finite elements method for assessment of the strain stress state (SSS) components were used as research methods. Rotation speed and material’s elasticity modulus varied during calculations, and SSS components and gas-dynamic parameters in the dynamic system of gas-dynamic flow and compressor rotor were evaluated. The analysis of time dependence demonstrated that gas-dynamic parameters near the rotor blades oscillate at 200 Hz, and SSS parameters at the upper blade edge oscillate four times higher, i.e. with blade frequency. It has been detected that vibration amplitudes correction in the test points at magnetic bearings by aeroelasticity may correspond up to 50%, and about -π/4 for phases.
Abstract: Due to the randomness and uncertainty of wind energy, modern power systems integrating large-scale wind generation will be significantly impacted in terms of system performance and technical challenges. System inertia with high wind penetration is decreasing when conventional thermal generators are gradually replaced by wind turbines, which do not naturally contribute to inertia response. The power imbalance caused by wind power or demand fluctuations leads to the instability of system frequency. Accordingly, the need to attach the supplementary virtual inertia control to wind farms (WFs) strongly arises. When multi-wind farms are connected to the grid simultaneously, the selection of which critical WFs to install the virtual inertia control is greatly important to enhance the stability of system frequency. By building the small signal model of wind power systems considering frequency regulation, the installation locations are identified by the geometric measures of the mode observability of WFs. In addition, this paper takes the impacts of grid topology and selection of feedback control signals into consideration. Finally, simulations are conducted on a multi-wind farms power system and the results demonstrate that the designed virtual inertia control method can effectively assist the frequency regulation.
Abstract: CRLH (composite right/left-handed) based and SRR (split-ring resonator) based filters have been designed at microwave frequency which can provide better performance compared to conventional edge-coupled band-pass filter designed around the same frequency, 2.45 GHz. Both CRLH and SRR are unit cells used in metamaterial design. The primary aim of designing filters with such structures is to realize size reduction and also to realize novel filter performance. The CRLH based filter has been designed in microstrip transmission line, while the SRR based filter is designed with SRR loading in waveguide. The CRLH based filter designed at 2.45 GHz provides an insertion loss of 1.6 dB with harmonic suppression up to 10 GHz with 67 % size reduction when compared with a conventional edge-coupled band-pass filter designed around the same frequency. One dimensional (1-D) SRR matrix loaded in a waveguide shows the possibility of realizing a stop-band with sharp skirts in the pass-band while a stop-band in the pass-band of normal rectangular waveguide with tailoring of the dimensions of SRR unit cells. Such filters are expected to be very useful for communication systems at microwave frequency.
Abstract: Using the numerical and experimental methods, this paper discusses some primary studies on the vibration and cooling performances of the piezoelectric cooling fan with the rectangular blade. When the fan works at its natural frequency, the vibrating displacement is largest and the cooling performance is best. Due to the vibration behavior, the cooling performance is affected by the geometry, material property, and working frequency of the piezoelectric cooling fan.
Abstract: A human’s hand localization is revised by using radar cross section (RCS) measurements with a minimum root mean square (RMS) error matching algorithm on a touchless keypad mock-up model. RCS and frequency transfer function measurements are carried out in an indoor environment on the frequency ranged from 3.0 to 11.0 GHz to cover federal communications commission (FCC) standards. The touchless keypad model is tested in two different distances between the hand and the keypad. The initial distance of 19.50 cm is identical to the heights of transmitting (Tx) and receiving (Rx) antennas, while the second distance is 29.50 cm from the keypad. Moreover, the effects of Rx angles relative to the hand of human factor are considered. The RCS input parameters are compared with power loss parameters at each frequency. From the results, the performance of the RCS input parameters with the second distance, 29.50 cm at 3 GHz is better than the others.
Abstract: The Hall Coefficient (HC) and the Magnetoresistance (MR) have been studied in two-dimensional systems. The HC and the MR in Rectangular Quantum Wire (RQW) subjected to a crossed DC electric field and magnetic field in the presence of a Strong Electromagnetic Wave (EMW) characterized by electric field are studied in this work. Using the quantum kinetic equation for electrons interacting with optical phonons, we obtain the analytic expressions for the HC and the MR with a dependence on magnetic field, EMW frequency, temperatures of systems and the length characteristic parameters of RQW. These expressions are different from those obtained for bulk semiconductors and cylindrical quantum wires. The analytical results are applied to GaAs/GaAs/Al. For this material, MR depends on the ratio of the EMW frequency to the cyclotron frequency. Indeed, MR reaches a minimum at the ratio 5/4, and when this ratio increases, it tends towards a saturation value. The HC can take negative or positive values. Each curve has one maximum and one minimum. When magnetic field increases, the HC is negative, achieves a minimum value and then increases suddenly to a maximum with a positive value. This phenomenon differs from the one observed in cylindrical quantum wire, which does not have maximum and minimum values.
Abstract: Fluctuations of Schottky diode parameters in a
structure of the mixer are investigated. These fluctuations are
manifested in two ways. At the first, they lead to fluctuations in the
transfer factor that is lead to the amplitude fluctuations in the signal
of intermediate frequency. On the basis of the measurement data of
1/f noise of the diode at forward current, the estimation of a spectrum
of relative fluctuations in transfer factor of the mixer is executed.
Current dependence of the spectrum of relative fluctuations in
transfer factor of the mixer and dependence of the spectrum of
relative fluctuations in transfer factor of the mixer on the amplitude
of the heterodyne signal are investigated. At the second, fluctuations
in parameters of the diode lead to occurrence of 1/f noise in the
output signal of the mixer. This noise limits the sensitivity of the
mixer to the value of received signal.
Abstract: Brushless DC motors (BLDC) are widely used in
industrial areas. The BLDC motors are driven either by indirect ACAC
converters or by direct AC-AC converters. Direct AC-AC
converters i.e. matrix converters are used in this paper to drive the
three phase BLDC motor and it eliminates the bulky DC link energy
storage element. A matrix converter converts the AC power supply to
an AC voltage of variable amplitude and variable frequency. A
control technique is designed to generate the switching pulses for the
three phase matrix converter. For the control of speed of the BLDC
motor a separate PI controller and Fuzzy Logic Controller (FLC) are
designed and a hysteresis current controller is also designed for the
control of motor torque. The control schemes are designed and tested
separately. The simulation results of both the schemes are compared
and contrasted in this paper. The results show that the fuzzy logic
control scheme outperforms the PI control scheme in terms of
dynamic performance of the BLDC motor. Simulation results are
validated with the experimental results.
Abstract: Microcantilevers are the basic MEMS devices, which
can be used as sensors, actuators and electronics can be easily built
into them. The detection principle of microcantilever sensors is based
on the measurement of change in cantilever deflection or change in its
resonance frequency. The objective of this work is to explore the
analogies between mechanical and electrical equivalent of
microcantilever beams. Normally scientists and engineers working in
MEMS use expensive software like CoventorWare, IntelliSuite,
ANSYS/Multiphysics etc. This paper indicates the need of developing
electrical equivalent of the MEMS structure and with that, one can
have a better insight on important parameters, and their interrelation of
the MEMS structure. In this work, considering the mechanical model
of microcantilever, equivalent electrical circuit is drawn and using
force-voltage analogy, it is analyzed with circuit simulation software.
By doing so, one can gain access to powerful set of intellectual tools
that have been developed for understanding electrical circuits Later
the analysis is performed using ANSYS/Multiphysics - software based
on finite element method (FEM). It is observed that both mechanical
and electrical domain results for a rectangular microcantlevers are in
agreement with each other.
Abstract: Pure nickel coatings have been successfully
electrodeposited on copper substrates by the pulse plating technique.
The influence of current density, duty cycle and pulse frequency on
the surface morphology, crystal orientation, and microhardness was
determined. It was found that the crystallite size of the deposit
increases with increasing current density and duty cycle. The crystal
orientation progressively changed from a random texture at 1 A/dm2
to (200) texture at 10 A/dm2. Increasing pulse frequency resulted in
increased texture coefficient and peak intensity of (111) reflection.
An increase in duty cycle resulted in considerable increase in texture
coefficient and peak intensity of (311) reflection. Coatings obtained
at high current densities and duty cycle present a mixed morphology
of small and large grains. Maximum microhardness of 193 Hv was
achieved at 4 A/dm2, 10 Hz and duty cycle of 50%. Nickel coatings
with (200) texture are ductile while (111) texture improves the
microhardness of the coatings.
Abstract: Graphene, a single-atom sheet, has been considered as
the most promising material for making future nanoelectromechanical
systems as well as purely electrical switching with graphene
transistors. Graphene-based devices have advantages in scaled-up
device fabrication due to the recent progress in large area graphene
growth and lithographic patterning of graphene nanostructures. Here
we investigated its mechanical responses of circular graphene
nanoflake under the nanoindentation using classical molecular
dynamics simulations. A correlation between the load and the
indentation depth was constructed. The nanoindented force in this
work was applied to the center point of the circular graphene nanoflake
and then, the resonance frequency could be tuned by a nanoindented
depth. We found the hardening or the softening of the graphene
nanoflake during its nanoindented-deflections, and such properties
were recognized by the shift of the resonance frequency. The
calculated mechanical parameters in the force-vs-deflection plot were
in good agreement with previous experimental and theoretical works.
This proposed schematics can detect the pressure via the deflection
change or/and the resonance frequency shift, and also have great
potential for versatile applications in nanoelectromechanical systems.
Abstract: This paper presents a grid synchronization technique based on adaptive notch filter for SPV (Solar Photovoltaic) system along with MPPT (Maximum Power Point Tracking) techniques. An efficient grid synchronization technique offers proficient detection of various components of grid signal like phase and frequency. It also acts as a barrier for harmonics and other disturbances in grid signal. A reference phase signal synchronized with the grid voltage is provided by the grid synchronization technique to standardize the system with grid codes and power quality standards. Hence, grid synchronization unit plays important role for grid connected SPV systems. As the output of the PV array is fluctuating in nature with the meteorological parameters like irradiance, temperature, wind etc. In order to maintain a constant DC voltage at VSC (Voltage Source Converter) input, MPPT control is required to track the maximum power point from PV array. In this work, a variable step size P & O (Perturb and Observe) MPPT technique with DC/DC boost converter has been used at first stage of the system. This algorithm divides the dPpv/dVpv curve of PV panel into three separate zones i.e. zone 0, zone 1 and zone 2. A fine value of tracking step size is used in zone 0 while zone 1 and zone 2 requires a large value of step size in order to obtain a high tracking speed. Further, adaptive notch filter based control technique is proposed for VSC in PV generation system. Adaptive notch filter (ANF) approach is used to synchronize the interfaced PV system with grid to maintain the amplitude, phase and frequency parameters as well as power quality improvement. This technique offers the compensation of harmonics current and reactive power with both linear and nonlinear loads. To maintain constant DC link voltage a PI controller is also implemented and presented in this paper. The complete system has been designed, developed and simulated using SimPower System and Simulink toolbox of MATLAB. The performance analysis of three phase grid connected solar photovoltaic system has been carried out on the basis of various parameters like PV output power, PV voltage, PV current, DC link voltage, PCC (Point of Common Coupling) voltage, grid voltage, grid current, voltage source converter current, power supplied by the voltage source converter etc. The results obtained from the proposed system are found satisfactory.
Abstract: Nowadays, energy dissipation devices are commonly
used in structures. High rate of energy absorption during earthquakes
is the benefit of using such devices, which results in damage
reduction of structural elements, specifically columns. The hysteretic
damping capacity of energy dissipation devices is the key point that it
may adversely make analysis and design process complicated. This
effect may be generally represented by Equivalent Viscous Damping
(EVD). The equivalent viscous damping might be obtained from the
expected hysteretic behavior regarding to the design or maximum
considered displacement of a structure. In this paper, the hysteretic
damping coefficient of a steel Moment Resisting Frame (MRF),
which its performance is enhanced by a Buckling Restrained Brace
(BRB) system has been evaluated. Having foresight of damping
fraction between BRB and MRF is inevitable for seismic design
procedures like Direct Displacement-Based Design (DDBD) method.
This paper presents an approach to calculate the damping fraction for
such systems by carrying out the dynamic nonlinear time history
analysis (NTHA) under harmonic loading, which is tuned to the
natural system frequency. Two MRF structures, one equipped with
BRB and the other without BRB are simultaneously studied.
Extensive analysis shows that proportion of each system damping
fraction may be calculated by its shear story portion. In this way,
contribution of each BRB in the floors and their general contribution
in the structural performance may be clearly recognized, in advance.
Abstract: We investigate experimentally and theoretically the
dynamics of a capacitive resonator under mixed frequency excitation
of two AC harmonic signals. The resonator is composed of a proof
mass suspended by two cantilever beams. Experimental
measurements are conducted using a laser Doppler Vibrometer to
reveal the interesting dynamics of the system when subjected to twosource
excitation. A nonlinear single-degree-of-freedom model is
used for the theoretical investigation. The results reveal combination
resonances of additive and subtractive type, which are shown to be
promising to increase the bandwidth of the resonator near primary
resonance frequency. Our results also demonstrate the ability to shift
the combination resonances to much lower or much higher frequency
ranges. We also demonstrate the dynamic pull-in instability under
mixed frequency excitation.
Abstract: Due to the continuous increment of the load demand,
identification of weaker buses, improvement of voltage profile and
power losses in the context of the voltage stability problems has
become one of the major concerns for the larger, complex,
interconnected power systems. The objective of this paper is to
review the impact of Flexible AC Transmission System (FACTS)
controller in Wind generators connected electrical network for
maintaining voltage stability. Wind energy could be the growing
renewable energy due to several advantages. The influence of wind
generators on power quality is a significant issue; non uniform power
production causes variations in system voltage and frequency.
Therefore, wind farm requires high reactive power compensation; the
advances in high power semiconducting devices have led to the
development of FACTS. The FACTS devices such as for example
SVC inject reactive power into the system which helps in maintaining
a better voltage profile. The performance is evaluated on an IEEE 14
bus system, two wind generators are connected at low voltage buses
to meet the increased load demand and SVC devices are integrated at
the buses with wind generators to keep voltage stability. Power
flows, nodal voltage magnitudes and angles of the power network are
obtained by iterative solutions using MIPOWER.
Abstract: This paper presents effects of the mean operating
pressure on the optimal operating frequency based on temperature
differences across stack ends in a thermoacoustic refrigerator. In
addition to the length of the resonance tube, components of the
thermoacoustic refrigerator have an influence on the operating
frequency due to their acoustic properties, i.e., absorptivity,
reflectivity and transmissivity. The interference of waves incurs and
distorts the original frequency generated by the driver so that the
optimal operating frequency differs from the designs. These acoustic
properties are not parameters in the designs and be very complicated
to infer their responses. A prototype thermoacoustic refrigerator is
constructed and used to investigate its optimal operating frequency
compared to the design at various operating pressures. Helium and air
are used as working fluids during the experiments. The results
indicate that the optimal operating frequency of the prototype
thermoacoustic refrigerator using helium is at 6 bar and 490Hz or
approximately 20% away from the design frequency. The optimal
operating frequency at other mean pressures differs from the design
in an unpredictable manner, however, the optimal operating
frequency and pressure can be identified by testing.
Abstract: This paper presents the simulation results of the
effects of sampling frequency on the total harmonic distortion (THD)
of three-phase inverters using the space vector pulse width
modulation (SVPWM) and space vector control (SVC) algorithms.
The relationship between the variables was studied using curve fitting
techniques, and it has been shown that, for 50 Hz inverters, there is
an exponential relation between the sampling frequency and THD up
to around 8500 Hz, beyond which the performance of the model
becomes irregular, and there is an negative exponential relation
between the sampling frequency and the marginal improvement to
the THD. It has also been found that the performance of SVPWM is
better than that of SVC with the same sampling frequency in most
frequency range, including the range where the performance of the
former is irregular.
Abstract: Elastomeric dielectric material has recently become a
new alternative for actuator technology. The characteristics of
dielectric elastomers placed between two electrodes to withstand
large strain when electrodes are charged has attracted the attention of
many researcher to study this material for actuator technology. Thus,
in the past few years Danfoss Ventures A/S has established their own
dielectric electro-active polymer (DEAP), which was called
PolyPower.
The main objective of this work was to investigate the dynamic
characteristics for vibration control of a PolyPower actuator folded in
‘pull’ configuration. A range of experiments was carried out on the
folded actuator including passive (without electrical load) and active
(with electrical load) testing. For both categories static and dynamic
testing have been done to determine the behavior of folded DEAP
actuator.
Voltage-Strain experiments show that the DEAP folded actuator is
a non-linear system. It is also shown that the voltage supplied has no
effect on the natural frequency. Finally, varying AC voltage with
different amplitude and frequency shows the parameters that
influence the performance of DEAP folded actuator. As a result, the
actuator performance dominated by the frequency dependence of the
elastic response and was less influenced by dielectric properties.
Abstract: This paper represents performance of particle swarm
optimisation (PSO) algorithm based integral (I) controller and
proportional-integral controller (PI) for interconnected hydro-thermal
automatic generation control (AGC) with generation rate constraint
(GRC) and Thyristor controlled phase shifter (TCPS) in series with
tie line. The control strategy of TCPS provides active control of
system frequency. Conventional objective function integral square
error (ISE) and another objective function considering square of
derivative of change in frequencies of both areas and change in tie
line power are considered. The aim of designing the objective
function is to suppress oscillation in frequency deviations and change
in tie line power oscillation. The controller parameters are searched
by PSO algorithm by minimising the objective functions. The
dynamic performance of the controllers I and PI, for both the
objective functions, are compared with conventionally optimized I
controller.
Abstract: The power converter that feeds high-frequency, highvoltage
transformers must be carefully designed due to parasitic
components, mainly the secondary winding capacitance and the
leakage inductance, that introduces resonances in relatively lowfrequency
range, next to the switching frequency. This paper
considers applications in which the load (resistive) has an
unpredictable behavior, changing from open to short-circuit condition
faster than the output voltage control loop could react. In this context,
to avoid overvoltage and over current situations, that could damage
the converter, the transformer or the load, it is necessary to find an
operation point that assure the desired output voltage in spite of the
load condition. This can done adjusting the frequency response of the
transformer adding an external inductance, together with selecting the
switching frequency to get stable output voltage independently of the
load.