Abstract: A new concept of response system is proposed for
filling the gap that exists in reducing vulnerability during immediate
response to natural disasters. Real Time Early Response Systems
(RTERSs) incorporate real time information as feedback data for
closing control loop and for generating real time situation assessment.
A review of the state of the art on works that fit the concept of
RTERS is presented, and it is found that they are mainly focused on
manmade disasters. At the same time, in response phase of natural
disaster management many works are involved in creating early
warning systems, but just few efforts have been put on deciding what
to do once an alarm is activated. In this context a RTERS arises as a
useful tool for supporting people in their decision making process
during natural disasters after an event is detected, and also as an
innovative context for applying well-known automation technologies
and automatic control concepts and tools.
Abstract: The aged are faced with increasing risk for falls. The
aged have the easily fragile bones than others. When falls have
occurred, it is important to detect this emergency state because such
events often lead to more serious illness or even death. A
implementation of PDA system, for detection of emergency situation,
was developed using 3-axis accelerometer in this paper as follows.
The signals were acquired from the 3-axis accelerometer, and then
transmitted to the PDA through Bluetooth module. This system can
classify the human activity, and also detect the emergency state like
falls. When the fall occurs, the system generates the alarm on the
PDA. If a subject does not respond to the alarm, the system determines
whether the current situation is an emergency state or not, and then
sends some information to the emergency center in the case of urgent
situation. Three different studies were conducted on 12 experimental
subjects, with results indicating a good accuracy. The first study was
performed to detect the posture change of human daily activity. The
second study was performed to detect the correct direction of fall. The
third study was conducted to check the classification of the daily
physical activity. Each test was lasted at least 1 min. in third study.
The output of acceleration signal was compared and evaluated by
changing a various posture after attaching a 3-axis accelerometer
module on the chest. The newly developed system has some important
features such as portability, convenience and low cost. One of the
main advantages of this system is that it is available at home
healthcare environment. Another important feature lies in low cost to
manufacture device. The implemented system can detect the fall
accurately, so will be widely used in emergency situation.