Abstract: The aerodynamic noise radiation from a side view mirror (SVM) in the high-speed airflow is calculated by the combination of unsteady incompressible fluid flow analysis and acoustic analysis. The transient flow past the generic SVM is simulated with variable turbulence model, namely DES Detached Eddy Simulation and LES (Large Eddy Simulation). Detailed velocity vectors and contour plots of the time-varying velocity and pressure fields are presented along cut planes in the flow-field. Mean and transient pressure are also monitored at several points in the flow field and compared to corresponding experimentally data published in literature. The acoustic predictions made using the Ffowcs-Williams-Hawkins acoustic analogy (FW-H) and the boundary element (BEM).
Abstract: Appropriate ventilation in a classroom is helpful for
enhancing air exchange rate and student concentration. This study
focuses on the effects of fenestration in a four-story school building by
performing numerical simulation of a building when considering
indoor and outdoor environments simultaneously. The wind profile
function embedded in PHOENICS code was set as the inlet boundary
condition in a suburban environment. Sixteen fenestration
combinations were compared in a classroom containing thirty seats.
This study evaluates mean age of air (AGE) and airflow pattern of a
classroom on different floors. Considering both wind profile and
fenestration effects, the airflow on higher floors is channeled toward
the area near ceiling in a room and causes older mean age of air in the
breathing zone. The results in this study serve as a useful guide for
enhancing natural ventilation in a typical school building.
Abstract: This paper addresses one important aspect of
combustion system analysis, the spray evaporation and
dispersion modeling. In this study we assume an empty
cylinder which is as a simulator for a ramjet engine and the
cylinder has been studied by cold flow. Four nozzles have the
duties of injection which are located in the entrance of
cylinder. The air flow comes into the cylinder from one side
and injection operation will be done. By changing injection
velocity and entrance air flow velocity, we have studied
droplet sizing and efficient mass fraction of fuel vapor near
and at the exit area. We named the mass of fuel vapor inside
the flammability limit as the efficient mass fraction. Further,
we decreased the initial temperature of fuel droplets and we
have repeated the investigating again. To fulfill the calculation
we used a modified version of KIVA-3V.
Abstract: Experiments have been performed to investigate the radiation effects on mixed convection heat transfer for thermally developing airflow in vertical ducts with two differentially heated isothermal walls and two adiabatic walls. The investigation covers the Reynolds number Re = 800 to Re = 2900, heat flux varied from 256 W/m2 to 863 W/m2, hot wall temperature ranges from 27°C to 100 °C, aspect ratios 1 & 0.5 and the emissivity of internal walls are 0.05 and 0.85. In the present study, combined flow visualization was conducted to observe the flow patterns. The effect of surface temperature along the walls was studied to investigate the local Nusselt number variation within the duct. The result shows that flow condition and radiation significantly affect the total Nusselt number and tends to reduce the buoyancy condition.
Abstract: The aerodynamics characteristics of a blended-wing body (BWB) aircraft were obtained in Universiti Teknologi MARA low speed wind tunnel. The scaled-down of BWB model consisted of a canard as its horizontal stabilizer. There were four canards with different aspect ratio used in the experiments. Canard setting angles were varied from -20q to 20q. All tests were conducted at velocity of 35 m/s, with Mach number 0.1. At low angles of attacks, the increment of lift slope for various canards aspect ratio is small and almost constant. Higher canard aspect ratio will cause higher drag. However, canard has a high effect to the moment at zero lift, CM,0.The visualization using mini tuff was performed to observe the airflow at the upper surface of canard. KeywordsAerodynamics,blended-wing body, canard, wind tunnel.
Abstract: This paper investigates experimental and numerical study of the airflow characteristics for vortex, round and square ceiling diffusers and its effect on the thermal comfort in a ventilated room. Three different thermal comfort criteria namely; Mean Age of the Air (MAA), ventilation effectiveness (E), and Effective Draft Temperature (EDT) have been used to predict the thermal comfort zone inside the room. In experimental work, a sub-scale room is set-up to measure the temperature field in the room. In numerical analysis, unstructured grids have been used to discretize the numerical domain. Conservation equations are solved using FLUENT commercial flow solver. The code is validated by comparing the numerical results obtained from three different turbulence models with the available experimental data. The comparison between the various numerical models shows that the standard k-ε turbulence model can be used to simulate these cases successfully. After validation of the code, effect of supply air velocity on the flow and thermal field could be investigated and hence the thermal comfort. The results show that the pressure coefficient created by the square diffuser is 1.5 times greater than that created by the vortex diffuser. The velocity decay coefficient is nearly the same for square and round diffusers and is 2.6 times greater than that for the vortex diffuser.
Abstract: In aerospace applications, interactions of airflow with
aircraft structures can result in undesirable structural deformations.
This structural deformation in turn, can be predicted if the natural
modes of the structure are known. This can be achieved through
conventional modal testing that requires a known excitation force in
order to extract these dynamic properties. This technique can be
experimentally complex because of the need for artificial excitation
and it is also does not represent actual operational condition. The
current work presents part of research work that address the practical
implementation of operational modal analysis (OMA) applied to a
cantilevered hybrid composite plate employing single contactless
sensing system via laser vibrometer. OMA technique extracts the
modal parameters based only on the measurements of the dynamic
response. The OMA results were verified with impact hammer modal
testing and good agreement was obtained.
Abstract: Clean air in subway station is important to passengers. The Platform Screen Doors (PSDs) can improve indoor air quality in the subway station; however the air quality in the subway tunnel is degraded. The subway tunnel has high CO2 concentration and indoor particulate matter (PM) value. The Indoor Air Quality (IAQ) level in subway environment degrades by increasing the frequency of the train operation and the number of the train. The ventilation systems of the subway tunnel need improvements to have better air-quality. Numerical analyses might be effective tools to analyze the performance of subway twin-track tunnel ventilation systems. An existing subway twin-track tunnel in the metropolitan Seoul subway system is chosen for the numerical simulations. The ANSYS CFX software is used for unsteady computations of the airflow inside the twin-track tunnel when the train moves. The airflow inside the tunnel is simulated when one train runs and two trains run at the same time in the tunnel. The piston-effect inside the tunnel is analyzed when all shafts function as the natural ventilation shaft. The supplied air through the shafts is mixed with the pollutant air in the tunnel. The pollutant air is exhausted by the mechanical ventilation shafts. The supplied and discharged airs are balanced when only one train runs in the twin-track tunnel. The pollutant air in the tunnel is high when two trains run simultaneously in opposite direction and all shafts functioned as the natural shaft cases when there are no electrical power supplies in the shafts. The remained pollutant air inside the tunnel enters into the station platform when the doors are opened.
Abstract: The Platform Screen Doors improve Indoor Air Quality
(IAQ) in the subway station; however, and the air quality is degraded
in the subway tunnel. CO2 concentration and indoor particulate matter
value are high in the tunnel. The IAQ level in subway tunnel degrades
by increasing the train movements. Air-curtain installation reduces
dusts, particles and moving toxic smokes and permits traffic by
generating virtual wall. The ventilation systems of the subway tunnel
need improvements to have better air-quality. Numerical analyses
might be effective tools analyze the flowfield inside the air-curtain
installed subway tunnel. The ANSYS CFX software is used for steady
computations of the airflow inside the tunnel. The single-track subway
tunnel has the natural shaft, the mechanical shaft, and the PSDs
installed stations. The height and width of the tunnel are 6.0 m and 4.0
m respectively. The tunnel is 400 m long and the air-curtain is installed
at the top of the tunnel. The thickness and the width of the air-curtain
are 0.08 m and 4 m respectively. The velocity of the air-curtain
changes between 20 - 30 m/s. Three cases are analyzed depending on
the installing location of the air-curtain. The discharged-air through
the natural shafts increases as the velocity of the air-curtain increases
when the air-curtain is installed between the mechanical and the
natural shafts. The pollutant-air is exhausted by the mechanical and the
natural shafts and remained air is pushed toward tunnel end. The
discharged-air through the natural shaft is low when the air-curtain
installed before the natural shaft. The mass flow rate decreases in the
tunnel after the mechanical shaft as the air-curtain velocity increases.
The computational results of the air-curtain installed tunnel become
basis for the optimum design study. The air-curtain installing location
is chosen between the mechanical and the natural shafts. The velocity
of the air-curtain is fixed as 25 m/s. The thickness and the blowing
angles of the air-curtain are the design variables for the optimum
design study. The object function of the design optimization is
maximizing the discharged air through the natural shaft.
Abstract: In this work, we experimentally study heat transfer
from exhaust particulate air of detergent spray drying tower to water
by using coiled tube heat exchanger. Water flows in the coiled
tubes, where air loaded with detergent particles of 43 micrometers
in diameter flows within the shell. Four coiled tubes with different
coil pitches are used in a counter-current flow configuration. We
investigate heat transfer coefficients of inside and outside the heat
transfer surfaces through 400 experiments. The correlations between
Nusselt number and Reynolds number, Prandtl number, mass flow
rate of particulates to mass flow rate of air ratio and coiled tube
pitch parameter are proposed. The correlations procured can be used
to predicted heat transfer between tube and shell of the heat
exchanger.