Abstract: Energy use is one of the main indicators for the economic and social development of a country, reflecting directly in the quality of life of the population. The expansion of energy use together with the depletion of fossil resources and the poor efficiency of energy systems have led many countries in recent years to invest in renewable energy sources. In this context, solar-assisted heat pump has become very important in energy industry, since it can transfer heat energy from the sun to water or another absorbing source. The direct-expansion solar assisted heat pump (DX-SAHP) water heater system operates by receiving solar energy incident in a solar collector, which serves as an evaporator in a refrigeration cycle, and the energy reject by the condenser is used for water heating. In this paper, a DX-SAHP using carbon dioxide as refrigerant (R744) was assembled, and the influence of the variation of the water mass flow rate in the system was analyzed. The parameters such as high pressure, water outlet temperature, gas cooler outlet temperature, evaporator temperature, and the coefficient of performance were studied. The mainly components used to assemble the heat pump were a reciprocating compressor, a gas cooler which is a countercurrent concentric tube heat exchanger, a needle-valve, and an evaporator that is a copper bare flat plate solar collector designed to capture direct and diffuse radiation. Routines were developed in the LabVIEW and CoolProp through MATLAB software’s, respectively, to collect data and calculate the thermodynamics properties. The range of coefficient of performance measured was from 3.2 to 5.34. It was noticed that, with the higher water mass flow rate, the water outlet temperature decreased, and consequently, the coefficient of performance of the system increases since the heat transfer in the gas cooler is higher. In addition, the high pressure of the system and the CO2 gas cooler outlet temperature decreased. The heat pump using carbon dioxide as a refrigerant, especially operating with solar radiation has been proven to be a renewable source in an efficient system for heating residential water compared to electrical heaters reaching temperatures between 40 °C and 80 °C.
Abstract: The objective of this work was to develop a theoretical model to study the dynamic thermal behavior of a flat plate solar collector integrated with a phase change material (PCM). The PCM acted as a heat source for the solar system during low intensity solar radiation and night. The energy balance equations for the various components of the collector as well as for the PCM were formulated and numerically solved using MATLAB computational program. The effect of natural convection on heat during the melting process was taken into account by using an effective thermal conductivity. The model was used to investigate the effect of inlet water temperature, water mass flow rate, and PCM thickness on the outlet water temperature and the melt fraction during charging and discharging modes. A comparison with a collector without PCM was made. Results showed that charging and discharging processes of PCM have six stages. The adding of PCM caused a decrease in temperature during charge and an increase during discharge. The rise was most enhanced for higher inlet water temperature, PCM thickness and for lower mass flow rate. Analysis indicated that the complete melting time was shorter than the solidification time due to the high heat transfer coefficient during melting. The increases in PCM height and mass flow rate were not linear with the melting and solidification times.
Abstract: The objective of this work was to develop a theoretical model to study the dynamic thermal behavior of a flat plate solar collector integrated with a phase change material (PCM). The PCM acted as a heat source for the solar system during low intensity solar radiation and night. The energy balance equations for the various components of the collector as well as for the PCM were formulated and numerically solved using Matlab computational program. The effect of natural convection on heat during the melting process was taken into account by using an effective thermal conductivity. The model was used to investigate the effect of inlet water temperature, water mass flow rate, and PCM thickness on the outlet water temperature and the melt fraction during charging and discharging modes. A comparison with a collector without PCM was made. Results showed that charging and discharging processes of PCM have six stages. The adding of PCM caused a decrease in temperature during charge and an increase during discharge. The rise was most enhanced for higher inlet water temperature, PCM thickness and for lower mass flow rate. Analysis indicated that the complete melting time was shorter than the solidification time due to the high heat transfer coefficient during melting. The increases in PCM height and mass flow rate were not linear with the melting and solidification times.
Abstract: This paper presents the experimental as well as the
simulated performance studies on the transcritical CO2 heat pumps
for simultaneous water cooling and heating; effects of water mass
flow rates and water inlet temperatures of both evaporator and gas
cooler on the cooling and heating capacities, system COP and water
outlets temperatures are investigated. Study shows that both the
water mass flow rate and inlet temperature have significant effect on
system performances. Test results show that the effect of evaporator
water mass flow rate on the system performances and water outlet
temperatures is more pronounced (COP increases 0.6 for 1 kg/min)
compared to the gas cooler water mass flow rate (COP increases 0.4
for 1 kg/min) and the effect of gas cooler water inlet temperature is
more significant (COP decreases 0.48 for given ranges) compared to
the evaporator water inlet temperature (COP increases 0.43 for given
ranges). Comparisons of experimental values with simulated results
show the maximum deviation of 5% for cooling capacity, 10% for
heating capacity, 16% for system COP. This study offers useful
guidelines for selecting appropriate water mass flow rate to obtain
required system performance.
Abstract: The present work demonstrates the design and simulation of a fuzzy control of an air conditioning system at different pressures. The first order Sugeno fuzzy inference system is utilized to model the system and create the controller. In addition, an estimation of the heat transfer rate and water mass flow rate injection into or withdraw from the air conditioning system is determined by the fuzzy IF-THEN rules. The approach starts by generating the input/output data. Then, the subtractive clustering algorithm along with least square estimation (LSE) generates the fuzzy rules that describe the relationship between input/output data. The fuzzy rules are tuned by Adaptive Neuro-Fuzzy Inference System (ANFIS). The results show that when the pressure increases the amount of water flow rate and heat transfer rate decrease within the lower ranges of inlet dry bulb temperatures. On the other hand, and as pressure increases the amount of water flow rate and heat transfer rate increases within the higher ranges of inlet dry bulb temperatures. The inflection in the pressure effect trend occurs at lower temperatures as the inlet air humidity increases.
Abstract: This paper presents the exergy analysis of a
desalination unit using humidification-dehumidification process.
Here, this unit is considered as a thermal system with three main
components, which are the heating unit by using a solar collector, the
evaporator or the humidifier, and the condenser or the dehumidifier.
In these components the exergy is a measure of the quality or grade
of energy and it can be destroyed in them. According to the second
law of thermodynamics this destroyed part is due to irreversibilities
which must be determined to obtain the exergetic efficiency of the
system.
In the current paper a computer program has been developed using
visual basic to determine the exergy destruction and the exergetic
efficiencies of the components of the desalination unit at variable
operation conditions such as feed water temperature, outlet air
temperature, air to feed water mass ratio and salinity, in addition to
cooling water mass flow rate and inlet temperature, as well as
quantity of solar irradiance.
The results obtained indicate that the exergy efficiency of the
humidifier increases by increasing the mass ratio and decreasing the
outlet air temperature. In the other hand the exergy efficiency of the
condenser increases with the increase of this ratio and also with the
increase of the outlet air temperature.