Abstract: This paper details the progress made in the development of the different state-of-the-art aerodynamic tools for the analysis of vertical axis wind turbines including the flow simulation around the blade, viscous flow, stochastic wind, and dynamic stall effects. The paper highlights the capabilities of the developed wind turbine aerodynamic codes over the last thirty years which are currently being used in North America and Europe by Sandia Laboratories, FloWind, IMST Marseilles, and Hydro-Quebec among others. The aerodynamic codes developed at Ecole Polytechnique de Montreal, Canada, represent valuable tools for simulating the flow around wind turbines including secondary effects. Comparison of theoretical results with experimental data have shown good agreement. The strength of the aerodynamic codes based on Double-Multiple Stream tube model (DMS) lies in its simplicity, accuracy, and ability to analyze secondary effects that interfere with wind turbine aerodynamic calculations.
Abstract: The cumulative costs for O&M may represent as
much as 65%-90% of the turbine's investment cost. Nowadays the
cost effectiveness concept becomes a decision-making and
technology evaluation metric. The cost of energy metric accounts for
the effect replacement cost and unscheduled maintenance cost
parameters. One key of the proposed approach is the idea of
maintaining the WTs which can be captured via use of a finite state
Markov chain. Such a model can be embedded within a probabilistic
operation and maintenance simulation reflecting the action to be
done. In this paper, an approach of estimating the cost of O&M is
presented. The finite state Markov model is used for decision
problems with number of determined periods (life cycle) to predict
the cost according to various options of maintenance.
Abstract: High resolution images are always desired as they contain the more information and they can better represent the original data. So, to convert the low resolution image into high resolution interpolation is done. The quality of such high resolution image depends on the interpolation function and is assessed in terms of sharpness of image. This paper focuses on Wavelet based Interpolation Techniques in which an input image is divided into subbands. Each subband is processed separately and finally combined the processed subbandsto get the super resolution image.
Abstract: Lightning protection systems (LPS) for wind power
generation is becoming an important public issue. A serious damage
of blades, accidents where low-voltage and control circuit
breakdowns are frequently occur in many wind farms. A grounding
system is one of the most important components required for
appropriate LPSs in wind turbines WTs. Proper design of a wind
turbine grounding system is demanding and several factors for the
proper and effective implementation must taken into account. In this
paper proposed procedure of proper design of grounding systems for
a wind turbine was introduced. This procedure depends on measuring
of ground current of simulated wind farm under lightning taking into
consideration the soil ionization. The procedure also includes the
Ground Potential Rise (GPR) and the voltage distributions at ground
surface level and Touch potential. In particular, the contribution of
mitigating techniques, such as rings, rods and the proposed design
were investigated.
Abstract: In this study, a field testing has been carried out to assess the power characteristics of some small scale wind turbines fabricated by one native technician from Tanzania. Two Horizontal Axis Wind Turbines (HAWTs), one with five and other with sixteen blades were installed at a height of 2.4m above the ground. The rotation speed of the rotor blade and wind speed approaching the turbines were measured simultaneously. The data obtained were used to determine how the power coefficient varies as a function of tip speed ratio and also the way in which the output power compares with available power in the wind for each turbine. For the sixteen-bladed wind turbine the maximum value of power coefficient of about 0.14 was found to occur at a tip speed ratio of around 0.65 while for the five bladed, these extreme values were respectively attained at approximately 0.2 and 1.7. The five bladed-wind turbine was found to have a higher power efficiency of about 37.5% which is higher compared to the sixteen bladed wind turbine whose corresponding value was 14.37%. This is what would be expected, as the smaller the number of blades of a wind turbine, the higher the electric power efficiency and vice versa. Some of the main reasons for the low efficiency of these machines may be due to the low aerodynamic efficiency of the turbine or low efficiency of the transmission mechanisms such as gearbox and generator which were not examined in this study. It is recommended that some other researches be done to investigate the power efficiency of such machines from different manufacturers in the country. The manufacturers should also be encouraged to use fewer blades in their designs so as to improve the efficiency and at the same time reduce materials used to fabricate the blades. The power efficiency of the electric generators used in the locally fabricated wind turbines should also be examined.
Abstract: This work presents a comparison between the Annual
Energy Output (AEO) of two commercial vertical-axis wind turbines
(VAWTs) for a low-wind urban site: both a drag-driven and a liftdriven
concepts are examined in order to be installed on top of the
new Via dei Giustinelli building, Trieste (Italy). The power-curves,
taken from the product specification sheets, have been matched to the
wind characteristics of the selected installation site. The influence of
rotor swept area and rated power on the performance of the two
proposed wind turbines have been examined in detail, achieving a
correlation between rotor swept area, electrical generator size and
wind distribution, to be used as a guideline for the calculation of the
AEO.
Abstract: Hysteresis phenomenon has been observed in the
operations of both horizontal-axis and vertical-axis wind turbines
(HAWTs and VAWTs). In this study, wind tunnel experiments were
applied to investigate the characters of hysteresis phenomena between
the angular speed and the external resistance of electrical loading
during the operation of a Darrieus type VAWT. Data of output voltage,
output current, angular speed of wind turbine under different wind
speeds are measured and analyzed. Results show that the range of
external resistance changes with the wind speed. The range decreases
as the wind speed increases following an exponential decay form.
Experiments also indicate that the maximum output power of wind
turbines is always inside the range where hysteresis happened. These
results provide an important reference to the design of output control
system of wind turbines.
Abstract: Waste management is now a global concern due to its
high environmental impact on climate change. Because of generating
huge amount of waste through our daily activities, managing waste in
an efficient way has become more important than ever. Alternative
Waste Technology (AWT), a new category of waste treatment
technology has been developed for energy recovery in recent years to
address this issue. AWT describes a technology that redirects waste
away from landfill, recovers more useable resources from the waste
flow and reduces the impact on the surroundings. Australia is one of
the largest producers of waste per-capita. A number of AWTs are
using in Australia to produce energy from waste. Presently, it is vital
to identify an appropriate AWT to establish a sustainable waste
management system in Australia. Identification of an appropriate
AWT through Multi-criteria analysis (MCA) of four AWTs by using
five key decision making criteria is presented and discussed in this
paper.
Abstract: The system is made with main distributed components:
First Level: Industrial Computers placed in Control Room (monitors thermal and electrical processes based on the data provided by the second level); Second Level: PLCs which collects data from process and transmits information on the first level; also takes commands from this level which are further, passed to execution elements from third
level; Third Level: field elements consisting in 3 categories: data collecting elements; data transfer elements from the third level to the second; execution elements which take commands from the second
level PLCs and executes them after which transmits the confirmation of execution to them. The purpose of the automatic functioning is the optimization of the co-generative electrical energy commissioning in the national
energy system and the commissioning of thermal energy to the consumers.
The integrated system treats the functioning of all the equipments and devices as a whole: Gas Turbine Units (GTU); MT 20kV Medium Voltage Station (MVS); 0,4 kV Low Voltage Station (LVS); Main Hot Water Boilers (MHW); Auxiliary Hot Water Boilers (AHW); Gas Compressor Unit (GCU); Thermal Agent Circulation
Pumping Unit (TPU); Water Treating Station (WTS).