Abstract: This paper introduces a digital method for fault section identification in transmission lines. The method uses digital set of the measured short circuit current to locate faults in electrical power systems. The digitized current is used to construct a set of overdetermined system of equations. The problem is then constructed and solved using the proposed digital optimization technique to find the fault distance. The proposed optimization methodology is an application of simulated annealing optimization technique. The method is tested using practical case study to evaluate the proposed method. The accurate results obtained show that the algorithm can be used as a powerful tool in the area of power system protection.
Abstract: Leakage current monitoring for high voltage transmission line insulators is of interest as a performance indicator. Presently, to the best of our knowledge, there is no commercially available, clamp-on type, non-intrusive device for measuring leakage current on energised high voltage direct current (HVDC) transmission line insulators. The South African power utility, Eskom, is investigating the development of such a hand-held sensor for two important applications; first, for continuous real-time condition monitoring of HVDC line insulators and, second, for use by live line workers to determine if it is safe to work on energised insulators. In this paper, a DC leakage current sensor based on magnetic field sensing techniques is developed. The magnetic field sensor used in the prototype can also detect alternating current up to 5 MHz. The DC leakage current prototype detects the magnetic field associated with the current flowing on the surface of the insulator. Preliminary HVDC leakage current measurements are performed on glass insulators. The results show that the prototype can accurately measure leakage current in the specified current range of 1-200 mA. The influence of external fields from the HVDC line itself on the leakage current measurements is mitigated through a differential magnetometer sensing technique. Thus, the developed sensor can perform measurements on in-service HVDC insulators. The research contributes to the body of knowledge by providing a sensor to measure leakage current on energised HVDC insulators non-intrusively. This sensor can also be used by live line workers to inform them whether or not it is safe to perform maintenance on energized insulators.
Abstract: There is a widespread changeover in the electrical power industry universally from old-style monopolistic outline towards a horizontally distributed competitive structure to come across the demand of rising consumption. When the transmission lines of derestricted system are incapable to oblige the entire service needs, the lines are overloaded or congested. The governor between customer and power producer is nominated as Independent System Operator (ISO) to lessen the congestion without obstructing transmission line restrictions. Among the existing approaches for congestion management, the frequently used approaches are reorganizing the generation and load curbing. There is a boundary for reorganizing the generators, and further loads may not be supplemented with the prevailing resources unless more private power producers are added in the system by considerably raising the cost. Hence, congestion is relaxed by appropriate Flexible AC Transmission Systems (FACTS) devices which boost the existing transfer capacity of transmission lines. The FACTs device, namely, Unified Power Flow Controller (UPFC) is preferred, and the correct placement of UPFC is more vital and should be positioned in the highly congested line. Hence, the weak line is identified by using power flow performance index with the new objective function with proposed hybrid Fish – Bee algorithm. Further, the location of UPFC at appropriate line reduces the branch loading and minimizes the voltage deviation. The power transfer capacity of lines is determined with and without UPFC in the identified congested line of IEEE 30 bus structure and the simulated results are compared with prevailing algorithms. It is observed that the transfer capacity of existing line is increased with the presented algorithm and thus alleviating the congestion.
Abstract: In electrical power system, high voltage insulators are necessary for consistent performance. All insulators are exposed to different mechanical and electrical stresses. Mechanical stresses occur due to various loads such as wind load, hardware and conductors weight. Electrical stresses are due to over voltages and operating voltages. The performance analysis of polymer insulators is an essential, as most of the electrical utility companies are employing polymer insulators for new and updated transmission lines. In this paper, electric field is analyzed for 400 kV silicone (SiR) composite insulator by COULOMB 3D software based on boundary element method. The field results are compared with EPRI reference values. Our results proved that values at critical regions are very less compared to EPRI reference values. And also experimentally 400 kV single V suspension string is evaluated as per IEC standards.
Abstract: Design of compact UWB multilayered microstrip filter with E-shape resonator is presented, which provides wide stopband up to 20 GHz and arbitrary impedance matching. The design procedure is developed based on the method of least squares and theory of N-coupled transmission lines. The dimensions of designed filter are about 11 mm × 11 mm and the three E-shape resonators are placed among four dielectric layers. The average insertion loss in the passband is less than 1 dB and in the stopband is about 30 dB up to 20 GHz. Its group delay in the UWB region is about 0.5 ns. The performance of the optimized filter design perfectly agrees with the microwave simulation softwares.
Abstract: This study and the field test comparisons were carried
out on the Algerian Derguna – Setif transmission systems. The
transmission line of normal voltage 225 kV is 65 km long,
transported and uses twin bundle conductors protected with two
shield wires of transposed galvanized steel. An iterative finite-element method is used to solve Poisons
equation. Two algorithms are proposed for satisfying the current
continuity condition and updating the space-charge density. A new approach to the problem of corona discharge in
transmission system has been described in this paper. The effect of
varying the configurations and wires number is also investigated. The
analysis of this steady is important in the design of HVDC
transmission lines. The potential and electric field have been
calculating in locations singular points of the system.
Abstract: Photonic Crystal Fibers (PCFs) can be used in optical
communications as transmission lines. For this reason, the PCFs with
low confinement loss, low chromatic dispersion, and low nonlinear
effects are highly suitable transmission media. In this paper, we
introduce a new design of index-guiding nanostructured photonic
crystal fiber (IG-NPCF) with ultra-low chromatic dispersion, low
nonlinearity effects, and low confinement loss. Relatively low
dispersion is achieved in the wavelength range of 1200 to 1600nm
using the proposed design. According to the new structure of
nanostructured PCF presented in this study, the chromatic dispersion
slope is -30(ps/km.nm) and the confinement loss reaches below 10-7
dB/km. While in the wavelength range mentioned above at the same
time an effective area of more than 50.2μm2 is obtained.
Abstract: With the current rise in the demand of electrical energy, present-day power systems which are large and complex, will continue to grow in both size and complexity. Flexible AC Transmission System (FACTS) controllers provide new facilities, both in steady state power flow control and dynamic stability control. Thyristor Controlled Series Capacitor (TCSC) is one of FACTS equipment, which is used for power flow control of active power in electric power system and for increase of capacities of transmission lines. In this paper, a Backstepping Power Flow Controller (BPFC) for TCSC in multimachine power system is developed and tested. The simulation results show that the TCSC proposed controller is capable of controlling the transmitted active power and improving the transient stability when compared with conventional PI Power Flow Controller (PIPFC).
Abstract: This paper presents a wavelet transform and Support
Vector Machine (SVM) based algorithm for estimating fault location
on transmission lines. The Discrete wavelet transform (DWT) is used
for data pre-processing and this data are used for training and testing
SVM. Five types of mother wavelet are used for signal processing to
identify a suitable wavelet family that is more appropriate for use in
estimating fault location. The results demonstrated the ability of SVM
to generalize the situation from the provided patterns and to
accurately estimate the location of faults with varying fault resistance.
Abstract: The protection of parallel transmission lines has been a challenging task due to mutual coupling between the adjacent circuits of the line. This paper presents a novel scheme for detection and classification of faults on parallel transmission lines. The proposed approach uses combination of wavelet transform and neural network, to solve the problem. While wavelet transform is a powerful mathematical tool which can be employed as a fast and very effective means of analyzing power system transient signals, artificial neural network has a ability to classify non-linear relationship between measured signals by identifying different patterns of the associated signals. The proposed algorithm consists of time-frequency analysis of fault generated transients using wavelet transform, followed by pattern recognition using artificial neural network to identify the type of the fault. MATLAB/Simulink is used to generate fault signals and verify the correctness of the algorithm. The adaptive discrimination scheme is tested by simulating different types of fault and varying fault resistance, fault location and fault inception time, on a given power system model. The simulation results show that the proposed scheme for fault diagnosis is able to classify all the faults on the parallel transmission line rapidly and correctly.
Abstract: A novel and efficient approach to realize
fractional-order capacitors is investigated in this paper. Meanwhile, a
new approach which is more efficient for semiconductor
implementation of fractional-order capacitors is proposed. The
feasibility of the approach has been verified with the preliminary
measured results.
Abstract: In this paper, the transformers over-load problem of Shiraz substation in Fars Regional Electric Company (FREC) is investigated for a period of three years plan. So the suggestions for using phase shifting transformer (PST) and unified power flow controller (UPFC) in order to solve this problem are examined in details and finally, some economical and practical designs will be given in order to solve the related problems. Practical consideration and using the basic and fundamental concept of powers in transmission lines in order to find the economical design are the main advantages of this research. The simulation results of the integrated overall system with different designs compare them base on economical and practical aspects to solve the over-load and loss-reduction.
Abstract: Protection system hidden failures have been identified as one of the main causes of system cascading collapse resulting to power system instability. In this paper, a systematic approach is presented in order to identify the probability of a system cascading collapse by taking into consideration the effect of protection system hidden failure. This includes the accurate calculation of the probability of hidden failure as it will provide significant impinge on the findings of the probability of system cascading collapse. The probability of a system cascading collapse is then used to identify the initial tripping of sensitive transmission lines which will contribute to a critical system cascading collapse. Based on the results obtained from this study, it is important to decide on the accurate value of the hidden failure probability as it will affect the probability of a system cascading collapse.
Abstract: This paper presents a model for analysis the induced voltage of transmission lines (energized) acting on neighboring distribution lines (de-energized). From environmental restrictions, 22 kV distribution lines need to be installed under 115 kV transmission lines. With the installation of the two parallel circuits like this, they make the induced voltage which can cause harm to operators. This work was performed with the ATP-EMTP modeling to analyze such phenomenon before field testing. Simulation results are used to find solutions to prevent danger to operators who are on the pole.
Abstract: The interline power flow controller (IPFC) is one of
the latest generation flexible AC transmission systems (FACTS)
controller used to control power flows of multiple transmission lines.
This paper presents a mathematical model of IPFC, termed as power
injection model (PIM). This model is incorporated in Newton-
Raphson (NR) power flow algorithm to study the power flow control
in transmission lines in which IPFC is placed. A program in
MATLAB has been written in order to extend conventional NR
algorithm based on this model. Numerical results are carried out on a
standard 2 machine 5 bus system. The results without and with IPFC
are compared in terms of voltages, active and reactive power flows to
demonstrate the performance of the IPFC model.
Abstract: This paper describes a finite-difference time-domainFDTD) method to analyze lightning surge propagation in electric transmission lines. Numerical computation of solving the Telegraphist-s equations is determined and investigated its effectiveness. A source of lightning surge wave on power transmission lines is modeled by using Heidler-s surge model. The
proposed method was tested against medium-voltage power
transmission lines in comparison with the solution obtained by using
lattice diagram. As a result, the calculation showed that the method is one of accurate methods to analyze transient
lightning wave in power transmission lines.
Abstract: This paper addresses the problems encountered by conventional distance relays when protecting double-circuit transmission lines. The problems arise principally as a result of the mutual coupling between the two circuits under different fault conditions; this mutual coupling is highly nonlinear in nature. An adaptive protection scheme is proposed for such lines based on application of artificial neural network (ANN). ANN has the ability to classify the nonlinear relationship between measured signals by identifying different patterns of the associated signals. One of the key points of the present work is that only current signals measured at local end have been used to detect and classify the faults in the double circuit transmission line with double end infeed. The adaptive protection scheme is tested under a specific fault type, but varying fault location, fault resistance, fault inception angle and with remote end infeed. An improved performance is experienced once the neural network is trained adequately, which performs precisely when faced with different system parameters and conditions. The entire test results clearly show that the fault is detected and classified within a quarter cycle; thus the proposed adaptive protection technique is well suited for double circuit transmission line fault detection & classification. Results of performance studies show that the proposed neural network-based module can improve the performance of conventional fault selection algorithms.
Abstract: Series compensators have been used for many years,
to increase the stability and load ability of transmission line. They
compensate retarded or advanced volt drop of transmission lines
by placing advanced or retarded voltage in series with them to
compensate the effective reactance, which cause to increase load
ability of transmission lines. In this paper, two method of fuzzy
controller, based on power reference tracking and impedance
reference tracking have been developed on TCSC controller in
order to increase load ability and improving power oscillation
damping of system. In these methods, fire angle of thyristors are
determined directly through the special Rule-bases with the error
and change of error as the inputs. The simulation results of two
area four- machines power system show the good performance of
power oscillation damping in system. Comparison of this method
with classical PI controller shows the increasing speed of system
response in power oscillation damping.
Abstract: This paper analyses the torsional efforts in gas turbine-generator shafts caused by high speed automatic reclosing of transmission lines. This issue is especially important for cases of three phase short circuit and unsuccessful reclosure of lines in the vicinity of the thermal plant. The analysis was carried out for the thermal plant TERMOPERNAMBUCO located on Northeast region of Brazil. It is shown that stress level caused by lines unsuccessful reclosing can be several times higher than terminal three-phase short circuit. Simulations were carried out with detailed shaft torsional model provided by machine manufacturer and with the “Alternative Transient Program – ATP" program [1]. Unsuccessful three phase reclosing for selected lines in the area closed to the plant indicated most critical cases. Also, reclosing first the terminal next to the gas turbine gererator will lead also to the most critical condition. Considering that the values of transient torques are very sensible to the instant of reclosing, simulation of unsuccessful reclosing with statistics ATP switch were carried out for determination of most critical transient torques for each section of the generator turbine shaft.
Abstract: A power cable is widely used for power supply in
power distributing networks and power transmission lines. Due to
limitations in the production, delivery and setting up power cables,
they are produced and delivered in several separate lengths. Cable
itself, consists of two cable terminations and arbitrary number of
cable joints, depending on the cable route length. Electrical stress
control is needed to prevent a dielectric breakdown at the end of the
insulation shield in both the air and cable insulation. Reliability of
cable joint depends on its materials, design, installation and operating
environment. The paper describes design and performance results for
new modeled cable joints. Design concepts, based on numerical
calculations, must be correct. An Equivalent Electrodes
Method/Boundary Elements Method-hybrid approach that allows
electromagnetic field calculations in multilayer dielectric media,
including inhomogeneous regions, is presented.