Abstract: Low-temperature waste heat is abundant in the process industries, and large amounts of Liquefied Natural Gas (LNG) cold energy are discarded without being recovered properly in LNG terminals. Power generation is an effective way to utilize low-temperature waste heat and LNG cold energy simultaneously. Organic Rankine Cycles (ORCs) and CO2 power cycles are promising technologies to convert low-temperature waste heat and LNG cold energy into electricity. If waste heat and LNG cold energy are utilized simultaneously in one system, the performance may outperform separate systems utilizing low-temperature waste heat and LNG cold energy, respectively. Low-temperature waste heat acts as the heat source and LNG regasification acts as the heat sink in the combined system. Due to the large temperature difference between the heat source and the heat sink, cascaded power cycle configurations are proposed in this paper. Cascaded power cycles can improve the energy efficiency of the system considerably. The cycle operating at a higher temperature to recover waste heat is called top cycle and the cycle operating at a lower temperature to utilize LNG cold energy is called bottom cycle in this study. The top cycle condensation heat is used as the heat source in the bottom cycle. The top cycle can be an ORC, transcritical CO2 (tCO2) cycle or supercritical CO2 (sCO2) cycle, while the bottom cycle only can be an ORC due to the low-temperature range of the bottom cycle. However, the thermodynamic path of the tCO2 cycle and sCO2 cycle are different from that of an ORC. The tCO2 cycle and the sCO2 cycle perform better than an ORC for sensible waste heat recovery due to a better temperature match with the waste heat source. Different combinations of the tCO2 cycle, sCO2 cycle and ORC are compared to screen the best configurations of the cascaded power cycles. The influence of the working fluid and the operating conditions are also investigated in this study. Each configuration is modeled and optimized in Aspen HYSYS. The results show that cascaded tCO2/ORC performs better compared with cascaded ORC/ORC and cascaded sCO2/ORC for the case study.
Abstract: Recently developed cooperative diversity scheme
enables a terminal to get transmit diversity through the support of other
terminals. However, most of the introduced cooperative schemes have
a common fault of decreased transmission rate because the destination
should receive the decodable compositions of symbols from the source
and the relay. In order to achieve high data rate, we propose a
cooperative scheme that employs hierarchical modulation. This
scheme is free from the rate loss and allows seamless cooperative
communication.
Abstract: In this paper, we describe the use of formal methods
to model malware behaviour. The modelling of harmful behaviour
rests upon syntactic structures that represent malicious procedures
inside malware. The malicious activities are modelled by a formal
grammar, where API calls’ components are the terminals and the set
of API calls used in combination to achieve a goal are designated
non-terminals. The combination of different non-terminals in various
ways and tiers make up the attack vectors that are used by harmful
software. Based on these syntactic structures a parser can be
generated which takes execution traces as input for pattern
recognition.
Abstract: Interaction between human, location and activity
defines space. In the framework of these relations, space is a
container for current specifications in relations of the 3 mentioned
elements. The change of land utility considered with average
performance range, urban regulations, society requirements etc. will
provide welfare and comfort for citizens. From an engineering view it
is fundamental that choosing a proper location for a specific civil
activity requires evaluation of locations from different perspectives.
The debate of desirable establishment of municipal service elements
in urban regions is one of the most important issues related to urban
planning. In this paper, the research type is applicable based on goal,
and is descriptive and analytical based on nature. Initially existing
terminals in Esfahan are surveyed and then new locations are
presented based on evaluated criteria. In order to evaluate terminals
based on the considered factors, an AHP model is used at first to
estimate weight of different factors and then existing and suggested
locations are evaluated using Arc GIS software and AHP model
results. The results show that existing bus terminals are located in
fairly proper locations. Further results of this study suggest new
locations to establish terminals based on urban criteria.
Abstract: We present an analytical model for the calculation of
the sensitivity, the spectral current noise and the detective parameter
for an optically illuminated In0.53Ga0.47As n+nn+ diode. The
photocurrent due to the excess carrier is obtained by solving the
continuity equation. Moreover, the current noise level is evaluated at
room temperature and under a constant voltage applied between the
diode terminals. The analytical calculation of the current noise in the
n+nn+ structure is developed by considering the free carries
fluctuations. The responsivity and the detection parameter are
discussed as functions of the doping concentrations and the emitter
layer thickness in one-dimensional homogeneous n+nn+ structure.
Abstract: In an interconnected power system, any sudden small
load perturbation in any of the interconnected areas causes the
deviation of the area frequencies, the tie line power and voltage
deviation at the generator terminals. This paper deals with the study
of performance of intelligent Fuzzy Logic controllers coupled with
Conventional Controllers (PI and PID) for Load Frequency Control.
For analysis, an isolated single area and interconnected two area
thermal power systems with and without generation rate constraints
(GRC) have been considered. The studies have been performed with
conventional PI and PID controllers and their performance has been
compared with intelligent fuzzy controllers. It can be demonstrated
that these controllers can successfully bring back the excursions in
area frequencies and tie line powers within acceptable limits in
smaller time periods and with lesser transients as compared to the
performance of conventional controllers under same load disturbance
conditions. The simulations in MATLAB have been used for
comparative studies.
Abstract: This paper focuses on the operational and strategic planning decisions related to the quayside of container terminals. We introduce an integrated operational research (OR) and system dynamics (SD) approach to solve the Berth Allocation Problem (BAP) and the Quay Crane Assignment Problem (QCAP). A BAP-QCAP optimization modeling approach which considers practical aspects not studied before in the integration of BAP and QCAP is discussed. A conceptual SD model is developed to determine the long-term effect of optimization on the system behavior factors like resource utilization, attractiveness to port, number of incoming vessels to port and port profits. The framework can be used for improving the operational efficiency of container terminals and providing a strategic view after applying optimization.
Abstract: In this paper, we present a cost-effective wireless
distributed load shedding system for non-emergency scenarios. In
power transformer locations where SCADA system cannot be used,
the proposed solution provides a reasonable alternative that combines
the use of microcontrollers and existing GSM infrastructure to send
early warning SMS messages to users advising them to proactively
reduce their power consumption before system capacity is reached
and systematic power shutdown takes place.
A novel communication protocol and message set have been
devised to handle the messaging between the transformer sites, where
the microcontrollers are located and where the measurements take
place, and the central processing site where the database server is
hosted. Moreover, the system sends warning messages to the endusers
mobile devices that are used as communication terminals. The
system has been implemented and tested via different experimental
results.
Abstract: Cooperative diversity (CD) has been adopted in many communication systems because it helps in improving performance of the wireless communication systems with the help of the relays that emulate the multiple antenna terminals. This work aims to provide the derivation of the performance analysis expressions of the multiuser diversity (MUD) in the two-hop cooperative multi-relay wireless networks (TCMRNs). Considering the work analysis, we provide analytically the derivation of a closed form expression of the two most commonly used performance metrics namely, the outage probability and the symbol error probability (SEP) for the fixed decode-and-forward (FDF) protocol with MUD.
Abstract: Recently, various services such as television and the
Internet have come to be received through various terminals.
However, we could gain greater convenience by receiving these
services through cellular phone terminals when we go out and then
continuing to receive the same services through a large screen digital
television after we have come home. However, it is necessary to go
through the same authentication processing again when using TVs
after we have come home. In this study, we have developed an
authentication method that enables users to switch terminals in
environments in which the user receives service from a server through
a terminal. Specifically, the method simplifies the authentication of
the server side when switching from one terminal to another terminal
by using previously authenticated information.
Abstract: In this paper, hybrid FDMA-TDMA access technique in a cooperative distributive fashion introducing and implementing a modified protocol introduced in [1] is analyzed termed as Power and Cooperation Diversity Gain Protocol (PCDGP). A wireless network consists of two users terminal , two relays and a destination terminal equipped with two antennas. The relays are operating in amplify-and-forward (AF) mode with a fixed gain. Two operating modes: cooperation-gain mode and powergain mode are exploited from source terminals to relays, as it is working in a best channel selection scheme. Vertical BLAST (Bell Laboratories Layered Space Time) or V-BLAST with minimum mean square error (MMSE) nulling is used at the relays to perfectly detect the joint signals from multiple source terminals. The performance is analyzed using binary phase shift keying (BPSK) modulation scheme and investigated over independent and identical (i.i.d) Rayleigh, Ricean-K and Nakagami-m fading environments. Subsequently, simulation results show that the proposed scheme can provide better signal quality of uplink users in a cooperative communication system using hybrid FDMATDMA technique.